Catachem Announces FDA Approval of the Albumin (ALB) In-Vitro Diagnostic (IVD) Chemistry Reagent Kit

Bridgeport, Connecticut, USA (November 13, 1987)…. Catachem, Inc. (Catachem, Private) announced today that it has received 510k clearance from the United States Food and Drug Administration (FDA) for the Albumin [BCG] (ALB) in vitro diagnostic chemistry reagent kit.

Measurements of Albumin (ALB) are used primarily for diagnosing liver and kidney diseases, as well as for monitoring the causes and treatments.  Human blood serum contains large amounts of protein. Two major groups of proteins in blood serum are albumin and globulin.  A total serum protein test measures the total amount of protein in blood serum as well as the amounts of albumin and globulin. The amounts of albumin and globulin can help a doctor diagnose certain diseases.  Albumin is produced mainly in the liver. It helps keep the blood from leaking out of blood vessels. When albumin levels drop, fluid may collect in the ankles (pedal edema), lungs (pulmonary edema), or abdomen (ascites). Albumin also helps carry some medications and other substances through the blood and is important for tissue growth and healing. This test is done on a blood sample taken from a vein.  BCG dye at a pH of 4.2 and in the presence of a non-ionic surfactant Brij-35 specifically binds albumin to form a colored BCG-albumin complex with maximum absorbance at 630 nm.  The increase in absorbance is directly proportional to the albumin concentration present in the sample.  ALB is a one reagent chemistry available in two sizes.  Reagents are packaged ready-to-use in small glass bottles. Calibrator and controls are available separately. ALB C244-01 1x500 ML, ALB C242-01 4x500 ML.

About Catachem, Inc.

Catachem has a rich 20 year history in clinical chemistry as a manufacturer and distributor of in-vitro chemistry products and services for human, veterinary and environmental laboratories. Catachem chemists helped develop many of the automated diagnostic chemistries widely in use today.  Catachem created the DiscretePak™ and VetSpec™ line of reagents for human and veterinary automated analyzers.  Catachem offers FDA approved (510K) chemistries (liquid and dry) including enzymatic chemistries developed in conjunction with IFCC and CDC.  Catachem has more than 500 applications for all types of analyzers including the Roche, Hitachi, Olympus, AU Series, RA Series, Opera, DAX, Bayer, Advia, Synchron, Beckman, Abbott and many other analyzers.  Corporate headquarters, research, custom formulation laboratories, and manufacturing are located in Bridgeport, Connecticut.  Catachem supplies leading laboratories and equipment manufacturers from distributors around the world. 

Forward-looking statements in this release are made pursuant to the ``safe harbor'' provision of the Private Securities Litigation Reform Act of 1995. Investors are cautioned that such forward-looking statements involve risks and uncertainties including, but not limited to, the results of research and development efforts, the effect of regulation by the United States Food and Drug Administration and other agencies, the impact of competitive products, product development commercialization and technological difficulties, and other risks detailed in the Company's periodic reports filed with the Securities and Exchange Commission.

Keywords: Catachem, Chemistry, Reagents, In-Vitro Diagnostics, IVD, Albumin, BCG, ALB, pedal edema, pulmonary edema, ascites

For more information contact:

Benjamin Twombly
Catachem, Inc.
70 Hawley Avenue
Bridgeport, CT
USA 06606
+1 (203) 335-9277 Office
+1 (203) 335-9977 FAX
bentwombly@aol.com
catachem@aol.com
www.catacheminc.com

Ref: C3012b

Catachem chemistries include: 5'-Nucleotidase (5NT), Adenosine Deaminase (ADA), Alanine Aminotransferase (ALT), Albumin BCG (ALB), a-L-Fucosidase (AFU), Alkaline Phosphatase (ALP), Ammonia (NH), Amylase (AMY), Aspartate Aminotransferase (ALP), β-Hydroxybutyrate (BHBA), Bicarbonate (HC03), Bile Acids (BA), Bilirubin, Direct with Blank (DBILI), Bilirubin, Total with Blank (TBILI), Bilirubin, Total (TBILI), Blood Urea Nitrogen (BUN), Bromide (BR), CO2 [340] (CO2), CO2 [380] (CO2), CO2 [single reagent] (CO2), Ca+++ Arsenazo [650NM] (CA3), Chloride [340 NM] (CL), Cholesterol (CH), Creatine Kinase (CK), Creatinine (CREAT), Fructosamine [millimole method] (FR), Fructosamine, Glycated Serum Protein [enzymatic] (FR), Gamma-Glutamyl Transpeptidase (GGT), Glucose Hexokinase (GLU), Glycated Hemoglobin (HbA1c), High Density Lipoproteins, Dextran Sulfate (HDL), Inorganic Phosphorus (IP), Lactate Dehydrogenase (LD), Lipase (LIP), Lithium [enzymatic] (LI), Magnesium (MG), N-Acetyl-ß-D-glucosaminidase (NAG), Potassium [enzymatic] (K), Plasma Free Hemoglobin (PFH), Pre-albumin (TBPA), Sodium [enzymatic] (NA), Sorbitol Dehydrogenase (SDH), Thiopurine methyltransferase (TPMT), Total Bile Acids (TBA), Total Iron (TI), Total Protein (TP), Triglycerides (TRIG), UIBC and TIBC (UIBC), Uric Acid (UA), Vitamin B6 (V6B), Multipoint Calibrator Catacal, Catatrol Level 1 Catatrol Level 2, Bile Acids Control, Bile Acids Calibrator, BHBA Calibrator, BHBA Control Level 1, BHBA Control Level 2; Bromide Calibrator, BR Control Level 1, BR Control Level 2; Fructosamine Calibrator, FR Control Level 1, FR Control Level 2, SDH Control Level 1, SDH  Control Level 2.  Call +1 (203) 335-9277 or Write Catachem@aol.com.

 

 

Nothing in this website should be used in place of personal medical advice from your own qualified medical practitioner.  See User Agreement

Send comments and feedback to:
Peter Barfoot Managing Director, BioPortfolio Ltd.
UK Tel: (+44) 1300 321501
USA Voicemail and Fax: (+1) 415 680 2472

All rights reserved. All other trademarks recognized.

BioPortfolio Limited is registered in England & Wales at Wessex Barn, Dorchester Road, Frampton, Dorset, DT2 9NB, UK. No.3312883 VAT No. GB 744 6483 10

Copyright © 1997-2008 - BioPortfolio Limited.