Morphological and functional evaluation of the bioresorption of the bioresorbable everolimus-eluting vascular scaffold using IVUS, echogenicity and vasomotion testing at two year follow-up: a patient level insight into the ABSORB A clinical trial.
Summary of "Morphological and functional evaluation of the bioresorption of the bioresorbable everolimus-eluting vascular scaffold using IVUS, echogenicity and vasomotion testing at two year follow-up: a patient level insight into the ABSORB A clinical trial."
The aim of this study was to describe vaso-reactivity (by Acetylcholine and Methergine tests) at 2 year follow-up in parallel with the individual changes in the echogenicity characteristics of the polymer struts of the everolimus eluting bioresorbable vascular scaffold (BVS), from post-treatment to 2 year follow-up, in patients enrolled in the ABSORB Cohort A study. Intravascular ultrasound assessment was performed with a phased array catheter (EagleEye, Volcano Corporation, Cordova, CA, USA) with automated pullback at 0.5 mm per second. The % ratio at 6 months and 2 years [(Scaffold Area post PCI- Lumen Area)/Scaffold Area post PCI] was calculated as a measure of scaffold shrinkage. The % change of hyperechogenicity was defined as: ([post-procedural hyperechogenicity] - [2 year follow up hyperechogenicity])/[post-procedural hyperechogenicity]) × 100. The vasomotion test with intracoronary acetylcholine (10(-6) M) or intravenous methergine (0.4 mg) was performed at 2 years. Overall nine patients received all these analyses and were enrolled in the present analysis. A 50-96% reduction in hyperechogenicity was observed between baseline and 2 years, which corresponded to a change in vasoreactivity between 2 and 22%. A vasoconstriction of the scaffolded segment was observed in the 5 patients, who underwent the methergine test, with a mean decrease in lumen diameter after methergine of 9 ± 7% (P = 0.06), while vasodilatation occurred in the 4 patients who underwent the acetylcholine test with a mean increase in lumen diameter after acetylcholine of 8 ± 5% (P = 0.125). Bioresorption of the BVS is accompanied by re-establishment of both endothelial and non-endothelial dependent vasomotion.
Affiliation
Thoraxcenter, Erasmus Medical Center, Bd583a, Dr. Molewaterplein 40, 3015-GD, Rotterdam, The Netherlands.
Journal Details
This article was published in the following journal.
Name: The international journal of cardiovascular imaging
ISSN: 1875-8312
Pages:
Links
- PubMed Source: http://www.ncbi.nlm.nih.gov/pubmed/21213050
- DOI: http://dx.doi.org/10.1007/s10554-010-9769-y
Medical and Biotech [MESH] Definitions
Diagnostic Imaging
Any visual display of structural or functional patterns of organs or tissues for diagnostic evaluation. It includes measuring physiologic and metabolic responses to physical and chemical stimuli, as well as ultramicroscopy.
Evaluation Studies As Topic
Studies determining the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. For drugs and devices, CLINICAL TRIALS AS TOPIC; DRUG EVALUATION; and DRUG EVALUATION, PRECLINICAL are available.
Program Evaluation
Studies designed to assess the efficacy of programs. They may include the evaluation of cost-effectiveness, the extent to which objectives are met, or impact.
Self-evaluation Programs
Educational programs structured in such a manner that the participating professionals, physicians, or students develop an increased awareness of their performance, usually on the basis of self-evaluation questionnaires.
Vascular Resistance
The force that opposes the flow of BLOOD through a vascular bed. It is equal to the difference in BLOOD PRESSURE across the vascular bed divided by the CARDIAC OUTPUT.
PubMed Articles
We investigated the 6-month clinical outcomes after implantation of second-generation 3.0-mm bioresorbable everolimus-eluting vascular scaffolds (BVS) in small coronary vessels (
Everolimus-eluting ABSORB bioresorbable vascular scaffold: present and future perspectives.
Everolimus-eluting ABSORB bioresorbable vascular scaffolds represent a novel approach that provides transient vessel support with drug-delivery capability without the long-term limitations of the meta...
Although serial changes in necrotic core and calcium are regarded as surrogates for the bioresorption process in patients treated with the bioresorbable everolimus-eluting vascular scaffolds (BVS), th...
The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed...
We sought to determine whether the differences in outcomes present between everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in the SPIRIT (Clinical Evaluation of the XIENCE V Everol...
Clinical Trials
Randomized Evaluation of Sirolimus-eluting Versus Everolimus-eluting Stent Trial
The purpose of this study is to evaluate whether the newly-approved everolimus-eluting stent is not inferior to the sirolimus-eluting stent in terms of the rate of target-lesion revascular...
ABSORB Clinical Investigation, Cohort B
The purpose of this study is to assess the safety and performance of the BVS Everolimus Eluting Coronary Stent System (EECSS) in the treatment of patients with a maximum of two de novo nat...
A Safety and Efficacy Study of the Dynalink®-E Everolimus Eluting Peripheral Stent System
The purpose of this first-in-man study is to evaluate the safety and performance of the Dynalink®-E everolimus eluting peripheral stent system for the treatment of patients with atheroscl...
SPIRIT II: A Clinical Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System
Prospective, randomized, active-control, single blind, parallel two-arm multi-center clinical trial comparing XIENCE V® Everolimus Eluting Coronary Stent System to the approved commercial...
Assessment of Stent Strut Coverage and Endothelial Function After Drug-Eluting Stents
The purpose of this study is to compare coronary endothelium function in patients with a zotarolimus-eluting versus a sirolimus-eluting or a everolimus-eluting stents with optical coherenc...