Evaluation of the iChem(®) Velocity™ Urine Chemistry Analyzer in a hospital routine laboratory.

06:00 EST 4th February 2011 | BioPortfolio

Summary of "Evaluation of the iChem(®) Velocity™ Urine Chemistry Analyzer in a hospital routine laboratory."

Abstract Background: The novel urine chemistry analyzer iChem Velocity (IRIS Diagnostics) offers improved urinalysis automation options through integration with the well-established iQ200 urine microscopy analyzer. In the course of optimizing the workflow in our hospital routine laboratory, we evaluated the performance of the iChem Velocity. Methods: A total of 257 random urine samples were analyzed with the iChem Velocity, iQ200, Clinitek Atlas (Siemens Healthcare Diagnostics) and by manual microscopy. Results: Depending on the parameter, 93% (hemoglobin) to 100% (urobilinogen), the iChem Velocity and Clinitek Atlas results agreed within the same rank or within one level of difference. The Clinitek Atlas featured a higher sensitivity for hemoglobin (area under the curve 0.86) and leukocyte esterase (area under the curve 0.85) compared with the iChem Velocity (area under the curve for hemoglobin 0.73, leukocytes 0.78). Imprecision was highest for hemoglobin and leukocytes in a pathological sample pool. While the precision of the Clinitek Atlas for hemoglobin measurements was superior, the iChem Velocity was more precise in analyzing protein and pH. Conclusions: Through urinalysis automation with the iChem Velocity and iQ200, we achieved a reduction of hands-on time by 89%. The sensitivity of this new system should be further improved through ongoing development.

Affiliation

Charité University Medicine Berlin, Institute of Laboratory Medicine and Pathobiochemistry, Berlin, Germany.

Journal Details

This article was published in the following journal.

Name: Clinical chemistry and laboratory medicine : CCLM / FESCC
ISSN: 1434-6621
Pages:

Links

DeepDyve research library

PubMed Articles [20000 Associated PubMed Articles listed on BioPortfolio]

Evaluation of an automated urinary iodine measurement using AU5800 analyzer with AutoLab Iodine reagent.

Evaluation of CareSens POCT Devices for Glucose Testing in the Routine Hospital Setting.

Glucose meters are used routinely in hospital wards to manage blood glucose levels in patients requiring frequent monitoring of blood glucose.

24-Hour Urine Samples Are More Reproducible Than Spot Urine Samples for Evaluation of Iodine Status in School-Age Children.

Variation in different urinary measurements for evaluation of iodine status is of concern to clinicians and researchers.

Comparative analysis of prostate cancer specific biomarkers PCA3 and ERG in whole urine, urinary sediments and exosomes.

PCA3 and ERG are mRNA-based prostate cancer (PCa) specific biomarkers that can be detected in urine. However, urine is a complex substrate that can be separated in several fractions. In this study we ...

Remote Evaluation of Rotational Velocity Using a Quadrant Photo-Detector and a DSC Algorithm.

This paper presents an approach to remotely evaluate the rotational velocity of a measured object by using a quadrant photo-detector and a differential subtraction correlation (DSC) algorithm. The rot...

Clinical Trials [4694 Associated Clinical Trials listed on BioPortfolio]

Evaluation of a New Sonoclot Device for Heparin Management in Cardiac Surgery

The SONOCLOT Analyzer (S1; Sienco, Inc. Boulder, CO USA, Model DP-2951) is used to perform kaolin-based activated clotting time as routine monitor of heparin therapy in patients undergoing...

Healthy.io Method Comparison & User Performance Study

The objectives of the Healthy.io Method Comparison and User Performance Study are: 1. To evaluate the performance of Dip.io Device in comparison to the ACON U500 Mission® U500 Uri...

Measurements of Corneal Biomechanical Properties Using a Dynamic Scheimpflug Analyzer for Young Healthy Adults in South Korea

The human cornea is affected by the magnitude and velocity of both internal and external forces because the cornea has both static and dynamic resistance components. Considering these natu...

Measurements of Corneal Biomechanical Properties Using a Dynamic Scheimpflug Analyzer for Normal Adults in South Korea

The human cornea is affected by the magnitude and velocity of both internal and external forces because the cornea has both static and dynamic resistance components. Considering these natu...

Influence of Rapydan on Clinical Chemistry and Hematology Measurements

There is an increasing awareness of the importance of treating procedure-related pain. Patients undergoing vascular access procedures are often afraid of needles and the discomfort associa...

Medical and Biotech [MESH] Definitions

The specialty of ANALYTIC CHEMISTRY applied to assays of physiologically important substances found in blood, urine, tissues, and other biological fluids for the purpose of aiding the physician in making a diagnosis or following therapy.

Diagnostic procedures, such as laboratory tests and x-rays, routinely performed on all individuals or specified categories of individuals in a specified situation, e.g., patients being admitted to the hospital. These include routine tests administered to neonates.

A mass spectrometry technique using two (MS/MS) or more mass analyzers. With two in tandem, the precursor ions are mass-selected by a first mass analyzer, and focused into a collision region where they are then fragmented into product ions which are then characterized by a second mass analyzer. A variety of techniques are used to separate the compounds, ionize them, and introduce them to the first mass analyzer. For example, for in GC-MS/MS, GAS CHROMATOGRAPHY-MASS SPECTROMETRY is involved in separating relatively small compounds by GAS CHROMATOGRAPHY prior to injecting them into an ionization chamber for the mass selection.

Measurement of the index of refraction (the ratio of the velocity of light or other radiation in the first of two media to its velocity in the second as it passes from one into the other).

The expenses incurred by a hospital in providing care. The hospital costs attributed to a particular patient care episode include the direct costs plus an appropriate proportion of the overhead for administration, personnel, building maintenance, equipment, etc. Hospital costs are one of the factors which determine HOSPITAL CHARGES (the price the hospital sets for its services).

Quick Search
Advertisement
 


DeepDyve research library

Relevant Topics

Urology
Benign Prostatic Hyperplasia (BPH) Erectile Dysfunction Urology Urology is the branch of medicine concerned with the urinary tract and diseases that affect it. Examples include urethritis, urethrostenosis and incontinence. Urology is a su...

Healthcare
Health care (or healthcare) is the diagnosis, treatment, and prevention of disease, illness, injury, and other physical and mental impairments in humans. Health care is delivered by practitioners in medicine, chiropractic, dentistry, nursing, pharmacy, a...