Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty.
Summary of "Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty."
PurposeTo compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP.MethodsThis prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland-Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP.ResultsiCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of -6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes.ConclusionsThe agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.Eye advance online publication, 25 March 2011; doi:10.1038/eye.2011.60.
Affiliation
Department of Ophthalmology, Azienda Ospedaliero-Universitaria 'Santa Maria della Misericordia', Udine, Italy.
Journal Details
This article was published in the following journal.
Name: Eye (London, England)
ISSN: 1476-5454
Pages:
Links
- PubMed Source: http://www.ncbi.nlm.nih.gov/pubmed/21436848
- DOI: http://dx.doi.org/10.1038/eye.2011.60
Medical and Biotech [MESH] Definitions
Tonometry, Ocular
Measurement of ocular tension (INTRAOCULAR PRESSURE) with a tonometer. (Cline, et al., Dictionary of Visual Science, 4th ed)
Cross-cultural Comparison
Comparison of various psychological, sociological, or cultural factors in order to assess the similarities or diversities occurring in two or more different cultures or societies.
Comparative Study
Comparison of outcomes, results, responses, etc for different techniques, therapeutic approaches or other inputs.
Ankle Brachial Index
Comparison of the BLOOD PRESSURE between the BRACHIAL ARTERY and the POSTERIOR TIBIAL ARTERY. It is a predictor of PERIPHERAL ARTERIAL DISEASE.
Prpc Proteins
Normal cellular isoform of prion proteins (PRIONS) encoded by a chromosomal gene and found in normal and scrapie-infected brain tissue, and other normal tissue. PrPC are protease-sensitive proteins whose function is unknown. Posttranslational modification of PrPC into PrPSC leads to infectivity.
PubMed Articles
Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting.
Purpose: To evaluate the clinical usefulness of a new rebound tonometer, Icare(®) PRO (Icare PRO), by comparison with Goldmann applanation tonometry (GAT) in a study on patients with glaucoma. Met...
Purpose: The purpose of this study was to evaluate the ICare tonometers precision and accuracy and the extent to which intraocular pressure (IOP) measurements are influenced by measuring position....
: The goals of our study were to analyze the correlation of rebound tonometer (RBT) and Goldmann applanation tonometer (GAT), assess the intraobserver and interobserver reproducibility of these tonome...
Evaluation of the self-tonometer Icare ONE in comparison to Goldmann applanation tonometry.
OBJECTIVE: The aim of this clinical study was to demonstrate the practicability of self-measured intraocular pressure and to evaluate the reliability by comparing the data with those obtained by Goldm...
To compare intraocular pressure (IOP) measurements obtained with Goldmann applanation (GAT) and dynamic contour tonometry (DCT) in a Mexican population. 40 glaucoma patients were included in this cros...
Clinical Trials
Assessment of a New Goldmann Applanation Tonometer
The classic Goldmann applanation tonometer has been further developed. The applanation principle has been retained, while the internal force transmission and the pressure gauging have been...
Icare Versus Haag-Streit Applanation Tonometer
The clinical performance of Icare ONE Tonometer TA02 was compared to a Goldmann type applanation tonometer (Haag-Streit). Data was collected according to ANSI Z80.10-2003 (ISO 8612.2) stan...
The purpose of this study is to evaluate an assessment of the intraocular pressure with the dynamic contour tonometry and the Goldmann applanation tonometry in patients with active anterio...
Systemic Endothelial Abnormalities in COPD
- The purpose of this project is to validate the peripheral arterial pressure waveform measurements technique of RAAP (radial artery applanation tonometry), in patients with mod...
Influence of Prostaglandins on Ocular Blood Flow in Glaucoma Patients
Vasoactivity of topical drugs may be of prognostic relevance in glaucoma. There is very little information for a major class, the prostaglandin analogues with regard to this aspect. The pu...