Advertisement

Polyethylene wear particles do not induce inflammation or gelatinase (MMP-2 and MMP-9) activity in fibrous tissue interfaces of loosening total hip arthroplasties.

12:41 EDT 20th May 2013 | BioPortfolio

Summary of "Polyethylene wear particles do not induce inflammation or gelatinase (MMP-2 and MMP-9) activity in fibrous tissue interfaces of loosening total hip arthroplasties."

In vitro and in vivo studies have suggested that polyethylene wear particles are the main cause for osteolysis in prosthetic loosening. Elevated amounts of proteases including gelatinases (or matrix metalloproteinases MMP-2 and MMP-9) have been found in fibrous tissue interfaces of loosened total hip arthroplasties suggesting that proteolysis plays a role in osteolysis. The presence of proteases does not mean that they are active, because activity of proteases is highly regulated at the post-translational level. We investigated whether the activity of two major proteases that are active extracellularly and have been associated with loosening, MMP-2 and MMP-9, is involved in loosening of non-cemented hip implants with polyethylene acetabular components. Eight interface tissues retrieved during revision were studied with light and electron microscopy and by in situ zymography to localize MMP-2 and MMP-9 activity in combination with immunohistochemistry to localize MMP-2 and MMP-9 proteins. All interface tissues contained large amounts of polyethylene wear particles, either in large accumulations or dispersed in the extracellular matrix or intracellularly in fibroblasts. Particles were not encountered in association with MMP-2 or MMP-9 activity or leukocytes. Inflammation was never found. MMP-9 activity was restricted to macrophages and MMP-2 activity was restricted to microvascular endothelial cells mainly outside areas where particles were present. Our data indicate that wear particles do not induce activation of leukocytes or MMP-2 or MMP-9 activity. Therefore, aseptic loosening may not be particle induced but initiated by other mechanisms such as mechanical stress.

Affiliation

Department of Orthopedics, St. Jansdal Ziekenhuis, Harderwijk, The Netherlands.

Journal Details

This article was published in the following journal.

Name: Acta histochemica
ISSN: 1618-0372
Pages:

Links

Medical and Biotech [MESH] Definitions

Dental Restoration Wear

Occlusal wear of the surfaces of restorations and surface wear of dentures.

Polyethylene

A vinyl polymer made from ethylene. It can be branched or linear. Branched or low-density polyethylene is tough and pliable but not to the same degree as linear polyethylene. Linear or high-density polyethylene has a greater hardness and tensile strength. Polyethylene is used in a variety of products, including implants and prostheses.

Elementary Particle Interactions

The interactions of particles responsible for their scattering and transformations (decays and reactions). Because of interactions, an isolated particle may decay into other particles. Two particles passing near each other may transform, perhaps into the same particles but with changed momenta (elastic scattering) or into other particles (inelastic scattering). Interactions fall into three groups: strong, electromagnetic, and weak. (From McGraw-Hill Encyclopedia of Science & Technology, 7th ed)

Anthracosilicosis

A form of pneumoconiosis caused by inhalation of dust that contains both CARBON and crystalline SILICON DIOXIDE. These foreign matters induce fibrous nodule formation in the lung.

Fibrous Dysplasia Of Bone

A disease of bone marked by thinning of the cortex and replacement of bone marrow by gritty fibrous tissue containing bony spicules, producing pain, disability, and gradually increasing deformity. Only one bone may be involved (FIBROUS DYSPLASIA, MONOSTOTIC) or several (FIBROUS DYSPLASIA, POLYOSTOTIC). (From Dorland, 28th ed)

PubMed Articles [ 17884 Associated PubMed Articles listed on BioPortfolio]

Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Larger femoral heads lead to a decreased risk of total hip dislocation and an improved range of motion. However, the larger diameter is associated with increased wear rates. The low wear rates of cros...

Polyethylene and metal wear particles: characteristics and biological effects.

This paper first presents a brief overview about the mechanism of wear particle formation as well as wear particle characteristics in metal-on-polyethylene and metal-on-metal artificial hip joints. Th...

Binding of proteins to ultra high molecular weight polyethylene wear particles as a possible mechanism of macrophage and lymphocyte activation.

Binding of five human plasma proteins (IgG, serum albumin, α(1)-acid glycoprotein, holo-transferrin, α(1)-antitrypsin) to ultra high molecular weight polyethylene wear particles (0.1-10 μm) isolate...

The John Charnley Award: An Accurate and Sensitive Method to Separate, Display, and Characterize Wear Debris: Part 1: Polyethylene Particles.

BACKGROUND: Numerous studies indicate highly crosslinked polyethylenes reduce the wear debris volume generated by hip arthroplasty acetabular liners. This, in turns, requires new...

The transport of wear particles in the prosthetic hip joint: A computational fluid dynamics investigation.

The joint fluid mechanics and transport of wear particles in the prosthetic hip joint were analyzed for subluxation and flexion motion using computational fluid dynamics (CFD). The entire joint space...

Clinical Trials [ 2682 Associated Clinical Trials listed on BioPortfolio]

Study to Explore the Effects of Two Hour Inhalation of Ultrafine Carbon Black Particles on Airway Inflammation in Asthmatics

The aim of the study is to test the hypothesis that the allergic airway inflammation in asthmatic patients will be enhanced after exposure to ultrafine particles (UFP). In order to test th...

A Randomised Single Centre Study to Compare the Long-Term Wear Characteristics of Marathon™ and Enduron™ Polyethylene Cup Liners in Primary Total Hip Replacement

The purpose of this study is to compare the performance and compare the wear characteristics of two polyethylene cup liners, Marathon™ and Enduron™, in the treatment of patients with h...

Does Extra-Fine Hydrofluoroalkane-Beclomethasone Dipropionate (HFA-BDP) Suppress Small Airways Inflammation in Chronic Obstructive Pulmonary Disease (COPD)?

Chronic obstructive pulmonary disease or 'COPD' is a chronic disease, which means that it cannot be cured, but that inhalers and tablets can be used to control the symptoms. In COPD, the a...

Evaluation of the Wear of Vitamin E Treated Polyethylene Components in Primary THA Using RSA

The specific aim of this proposed study is to conduct a prospective RSA clinical study at Massachusetts General Hospital involving 50 patients receiving primary total hip replacements. All...

A Phase I Safety and Immunogenicity Study of HIV p17/p24:Ty-VLP in HIV-1 Seronegative Subjects

To evaluate the safety and immunogenicity of HIV p17/p24:Ty-VLP (virus-like particles) vaccine in uninfected volunteers. Specifically, to determine whether the vaccine formulated with and...

Search BioPortfolio:
Advertisement
Advertisement