Advertisement

Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities.

01:45 EDT 20th June 2013 | BioPortfolio

Summary of "Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities."

The dialyzer housing structure should be designed in such a way that high dialysis performance is achieved. To achieve high dialysis performance, the flow of the dialysis fluid and blood should be uniform, without channeling and dead spaces. The objective of this study was to evaluate the effect of fiber packing density on the flow of dialysis fluid and blood, and on the dialysis performance of a hollow-fiber dialyzer at defined flow rates for blood (Q (B) = 200 mL/min), dialysis fluid (Q (D) = 500 mL/min), and filtrate (Q (F) = 0 mL/min). We measured Q (D), Q (B), and solute clearance for 3 test dialyzers with dialyzer housing different diameters. To evaluate the flow of dialysis fluid and blood, we measured the residence time of the dialysis fluid and blood in the test dialyzers by use of the pulse-response method. We also measured the clearances of urea, creatinine, vitamin B(12), and lysozyme to evaluate the dialysis performance of the test dialyzers. At packing densities ranging from 48 to 67%, higher packing densities and lower housing diameters of the dialyzer resulted in higher dialysis performance because the dialysis fluid and blood entered the hollow-fiber bundle smoothly and, hence, increased contact area between the dialysis fluid and the blood led to better dialysis performance.

Affiliation

Department of Chemical Engineering, Waseda University, 3-4-1, Okubo, Shinjuku-ku, Tokyo, 169-8555, Japan, tint-scent@akane.waseda.jp.

Journal Details

This article was published in the following journal.

Name: Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs
ISSN: 1619-0904
Pages:

Links

Medical and Biotech [MESH] Definitions

Renal Dialysis

Therapy for the insufficient cleansing of the BLOOD by the kidneys based on dialysis and including hemodialysis, PERITONEAL DIALYSIS, and HEMODIAFILTRATION.

Self-evaluation Programs

Educational programs structured in such a manner that the participating professionals, physicians, or students develop an increased awareness of their performance, usually on the basis of self-evaluation questionnaires.

Angioplasty, Balloon, Laser-assisted

Techniques using laser energy in combination with a balloon catheter to perform angioplasty. These procedures can take several forms including: 1, laser fiber delivering the energy while the inflated balloon centers the fiber and occludes the blood flow; 2, balloon angioplasty immediately following laser angioplasty; or 3, laser energy transmitted through angioplasty balloons that contain an internal fiber.

Rotarod Performance Test

A performance test based on forced MOTOR ACTIVITY on a rotating rod, usually by a rodent. Parameters include the riding time (seconds) or endurance. Test is used to evaluate balance and coordination of the subjects, particular in experimental animal models for neurological disorders and drug effects.

Peritoneal Dialysis, Continuous Ambulatory

Portable peritoneal dialysis using the continuous (24 hours a day, 7 days a week) presence of peritoneal dialysis solution in the peritoneal cavity except for periods of drainage and instillation of fresh solution.

PubMed Articles [ 22116 Associated PubMed Articles listed on BioPortfolio]

Enhancement of the predicted drug hepatotoxicity in gel entrapped hepatocytes within polysulfone-g-poly (ethylene glycol) modified hollow fiber.

Collagen gel-based 3D cultures of hepatocytes have been proposed for evaluation of drug hepatotoxicity because of their more reliability than traditional monolayer culture. The collagen gel entrapment...

Evaluation of an anion-exchange hollow-fiber membrane adsorber containing γ-ray grafted glycidyl methacrylate chains.

It is widely recognized that membrane adsorbers are powerful tools for the purification of biopharmaceutical protein products and for this reason a novel hollow-fiber AEX type membrane adsorber has be...

Single strand hollow fiber membrane (SSHFM): An on-line sample preparation for the flow based colorimetric determination of free iron in fruit juices.

A single strand hollow fiber membrane (SSHFM) was developed for the on-line sample preparation for the flow based colorimetric determination of free iron levels in fruit juices. The SSHFM, as used, co...

Dialyzers Designed to Increase Internal Filtration Do Not Result in Significantly Increased Platelet Activation and Thrombin Generation.

Introduction: To increase middle molecule clearances, high-flux dialyzers with increased internal filtration have been developed. However, dialyzer design and structure may affect thrombin generation...

Do Clinical Outcomes in Chronic Hemodialysis Depend on the Choice of a Dialyzer?

Nephrologists are presented with a range of choices when selecting a dialyzer for chronic hemodialysis. Dialyzers differ in the material, structure, permeability and surface area of their membrane, an...

Clinical Trials [ 3612 Associated Clinical Trials listed on BioPortfolio]

Inflammation and Nutritional Parameters in Hemodialysis Patients Using Reprocessed Dialyzers

The study is a prospective cohort trial utilizing sequential laboratory results from excess serum obtained from hemodialysis patients (acting as their own controls). The objective of this...

Study of How the Dose of Dialysis is Affected by Dialysate Flow Rate

The purpose of this study is to look at how the dose of dialysis is affected by the rate at which dialysate flows through the dialyzer. The dose of dialysis (Kt/V) will be determined by me...

A Study to Evaluate the Efficacy and Safety of an Experimental Solution for Peritoneal Dialysis

Objective: The purpose of this study is to demonstrate: -the non-inferiority of an experimental peritoneal dialysis solution compared to a current solution for the management of end stage...

Small-fiber Neuropathy in Chronic Kidney Disease

Neurological dysfunction is a common complication of late stage chronic kidney disease (CKD) and peripheral nerve system is often involved in such complication. Sensory disturbances such a...

Effects of Fiber on Satiety

The effects of a dietary fiber on hunger and food intake will be tested in men and women. Participants will receive fiber as part of a breakfast meal on two occasions. On another occasion,...

Search BioPortfolio: