Advertisement

A Selective, Colorimetric, and Fluorescent Chemodosimeter for Relay Recognition of Fluoride and Cyanide Anions Based on 1,1'-Binaphthyl Scaffold.

09:02 EDT 22nd May 2013 | BioPortfolio

Summary of "A Selective, Colorimetric, and Fluorescent Chemodosimeter for Relay Recognition of Fluoride and Cyanide Anions Based on 1,1'-Binaphthyl Scaffold."

The reaction-based relay recognition of fluoride and cyanide anions was demonstrated for the first time, with rapid response and unique triple (fluorescence color, intensity and absorption band) output modes in either of two sequential sensing events. Ratiometric determination of these two anions by fluorescence and/or absorbance spectra is also achieved.

Affiliation

State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, China.

Journal Details

This article was published in the following journal.

Name: Organic letters
ISSN: 1523-7052
Pages:

Links

Medical and Biotech [MESH] Definitions

Calcium Fluoride

Calcium fluoride. Occurring in nature as the mineral fluorite or fluorspar. It is the primary source of fluorine and its compounds. Pure calcium fluoride is used as a catalyst in dehydration and dehydrogenation and is used to fluoridate drinking water. (From Merck Index, 11th ed)

Sodium Fluoride

A source of inorganic fluoride which is used topically to prevent dental caries.

Tin Fluorides

Inorganic fluorides of tin. They include both stannic fluoride (tin tetrafluoride) and stannous fluoride (tin difluoride). The latter is used in the prevention of dental caries.

Hydrogen Cyanide

Hydrogen cyanide (HCN); A toxic liquid or colorless gas. It is found in the smoke of various tobacco products and released by combustion of nitrogen-containing organic materials.

Acidulated Phosphate Fluoride

A sodium fluoride solution, paste or powder, which has been acidulated to pH 3 to 4 and buffered with a phosphate. It is used in the prevention of dental caries.

PubMed Articles [ 11296 Associated PubMed Articles listed on BioPortfolio]

Colorimetric Probes Based on Anthraimidazolediones for Selective Sensing of Fluoride and Cyanide Ion via Intramolecular Charge Transfer.

Probes based on anthra[1,2-d]imidazole-6,11-dione were designed and synthesized for selective ion sensing. Each probe acted as strong colorimetric sensors for fluoride and cyanide ions and exhibited i...

Coumarin-Cu(II) Ensemble-Based Cyanide Sensing Chemodosimeter.

An "ensemble"-based chemodosimeter 1-Cu(II) for cyanide detection is reported. 1-Cu(II) can recognize a cyanide ion over other anionic species to show a marked fluorescence enhancement under aqueous c...

A highly selective colorimetric chemodosimeter for fast and quantitative detection of hydrogen sulfide.

Based on the fact that hydrogen sulfide (H(2)S) possesses the smallest steric hindrance among thiols and the SH(-) group adds faster to an electron-poor C[double bond, length as m-dash]C double bond,...

A novel glycoconjugated N-acetylamino aldehyde hydrazone azo dye as chromogenic probe for cyanide detection in water.

A new selective chemodosimeter probe of cyanide anions in aqueous media was developed by the introduction of a simple glyco-conjugated o-(carboxamido) aldehyde hydrazone into an azo dye as chemodosime...

A highly selective colorimetric and ratiometric two-photon fluorescent probe for fluoride ion detection.

A naphthalimide-based highly selective colorimetric and ratiometric fluorescent probe for the fluoride ion displayed both one- and two-photon ratiometric changes. Upon reaction with the F(-) (TBA(+) a...

Clinical Trials [ 488 Associated Clinical Trials listed on BioPortfolio]

Is it Possible to Treat Cyanide Poisoning With HBO?

People who has been in a fire accident have been shown often to be cyanide poisoned as well as poisoned with carbon monoxide(CO). According to recommendations from the Danish Health Agency...

Phase II Study of the Safety and Efficacy of the Relay Thoracic Stent-Graft

The purpose of this study is to evaluate the safety and efficacy of the Relay thoracic stent-graft system to treat thoracic aortic aneurysms. Efficacy will be evaluated by the device-rela...

Evaluation of Plaque Fluid Fluoride Retention From Fluoride Toothpastes

This study is to evaluate the amount of fluoride in plaque fluid after brushing iwth fluoride dentifrices

Development of Clinical Method to Determination Triclosan Retention in Plaque Following Brushing.

Clinical research study to determine the anti-plaque efficacy of prototype dentifrices via a 4-day brushing regiment

In Situ Caries Model of Fluoride Toothpastes

This study is to evaluate the effect of fluoride dentrifrices on enamel with artificial caries lesions in an in situ model

Search BioPortfolio:
Advertisement
Advertisement