Spectrofluorimetric Assessment of Hydrochlorothiazide Using Optical Sensor Nano-Composite Terbium Ion Doped in Sol-Gel Matrix.
Summary of "Spectrofluorimetric Assessment of Hydrochlorothiazide Using Optical Sensor Nano-Composite Terbium Ion Doped in Sol-Gel Matrix."
A new, simple, sensitive and selective spectrofluorimetric method for the determination of Hydrochlorothiazide was developed in acetonitrile at pH 6.2. The Hydrochlorothiazide can remarkably enhance the luminescence intensity of the Tb(3+) ion doped in sol-gel matrix at λ(ex) = 370 nm. The intensity of the emission band of Tb(3+) ion doped in sol-gel matrix was increased due to the energy transfer from the triplet excited state of Hydrochlorothiazide to ((5)D(4)) excited energy state of Tb(3) ion. The enhancement of the emission band of Tb(3+) ion doped in sol-gel matrix at ((5)D(4)→(7) F(5)) 545 nm was directly proportion to the concentration of Hydrochlorothiazide with a dynamic ranges of 5.0 × 10(-10)-5.0 × 10(-6) mol L(-1) and detection limit of 2.2 × 10(-11) mol L(-1).
Affiliation
Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo, Egypt, youssef_ao@yahoo.com.
Journal Details
This article was published in the following journal.
Name: Journal of fluorescence
ISSN: 1573-4994
Pages:
Links
- PubMed Source: http://www.ncbi.nlm.nih.gov/pubmed/22187361
- DOI: http://dx.doi.org/10.1007/s10895-011-1017-x
Medical and Biotech [MESH] Definitions
Needs Assessment
Systematic identification of a population's needs or the assessment of individuals to determine the proper level of services needed.
Outcome And Process Assessment (health Care)
Evaluation procedures that focus on both the outcome or status (OUTCOMES ASSESSMENT) of the patient at the end of an episode of care - presence of symptoms, level of activity, and mortality; and the process (ASSESSMENT, PROCESS) - what is done for the patient diagnostically and therapeutically.
Optical Devices
Products or parts of products used to detect, manipulate, or analyze light, such as LENSES, refractors, mirrors, filters, prisms, and OPTICAL FIBERS.
Tomography, Optical Coherence
An imaging method using LASERS that is used for mapping subsurface structure. When a reflective site in the sample is at the same optical path length (coherence) as the reference mirror, the detector observes interference fringes.
Neuronal Calcium-sensor Proteins
A family of intracellular calcium-sensing proteins found predominately in NEURONS and PHOTORECEPTOR CELLS. They contain EF HAND MOTIFS and undergo conformational changes upon calcium-binding. Neuronal calcium-sensor proteins interact with other regulatory proteins to mediate physiological responses to a change in intracellular calcium concentration.
PubMed Articles
A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of trace amounts of chlorzoxazone and Ibuprofen in pharmaceutical tablets using optical sensor E...
Pd-based integrated optical hydrogen sensor on a silicon-on-insulator platform.
We have experimentally demonstrated a compact, integrated optical hydrogen sensor on a silicon-on-insulator platform. The sensor consists of silicon waveguide coated with a thin palladium film. The se...
A novel and low-cost optical sensor for heavy metal ion detection has been prepared by immobilizing 4-(2-pyridylazo)-resorcinol (PAR) on the functionalized hexagonal mesoporous silica (HMS) via N-trim...
A deep ultraviolet-visible (DUV-Vis) reflected optical fiber sensor was developed for use in a simple spectrophotometric detection system to detect the absorption of various illegal drugs at wavelengt...
Clinical Trials
An Inpatient Evaluation of Six-Day Subcutaneous Glucose Sensor Performance
The purpose of this study is to assess the performance of the subcutaneous glucose sensor over an extended sensor life. The sensor is currently approved for 3 days of use and this study wi...
Proof-of Concept Study of Topical 3%-Diclofenac-Nano-Emulsion Cream for Knee OA Pain
This study valuates the safety and efficacy of treatment with 3% Diclofenac Nano-Emulsion Cream versus Placebo in subjects with osteoarthritis of the knee.
The purpose of this study is to assess performance of a new subcutaneous glucose sensor over a seven day sensor life when used with currently marketed Medtronic Diabetes devices. In additi...
An Exploratory Study on Optical Assessment of Oral Mucositis
Objectives: 1. To assess the tolerability of performing optical coherence tomography and/or optical spectroscopy in patients with acute oral mucositis. 2. To determine the...
Fasting Study of Hydrochlorothiazide Tablets 50 mg to Hydrochlorothiazide Tablets 50 mg
The objective of this study was to investigate the bioequivalence of Mylan's hydrochlorothiazide 50 mg tablets to Ivax's Hydrochlorothiazide 50 mg tablets following a single, oral 50 mg (1...