A novel device for improving marker placement accuracy.

02:09 EDT 29th May 2015 | BioPortfolio

Summary of "A novel device for improving marker placement accuracy."


BACKGROUND:
Repeatability of marker placement has been acknowledged as a major factor affecting the reliability of multi-segment foot models. A novel device is proposed that is intended to reduce marker placement error and its effect on the reliability of inter-segmental foot kinematic data is investigated.
METHOD:
The novel device was tested on eight healthy subjects. Landmarks were identified and indicated on the subject's foot at the start of testing using pen, and these points were used to guide placement. Markers were twice attached by a podiatrist using a standard approach, and twice by a researcher who used the novel device. Replacement accuracy and the kinematic reliability of the foot model data for both techniques were analysed.
RESULTS:
The mean marker placement variability using the novel device placement device was 1.1mm (SD 0.28) compared to 1.4mm (SD 0.23) when using standard placement techniques. Results suggest that these reductions in placement error tended to improve the overall reliability of the multi-segment data from the foot model.
DISCUSSION:
The novel device is a simple and inexpensive tool for improving the placement consistency of skin-mounted markers.

Affiliation

School of Health, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, United Kingdom.

Journal Details

This article was published in the following journal.

Name: Gait & posture
ISSN: 1879-2219
Pages:

Links

PubMed Articles [11235 Associated PubMed Articles listed on BioPortfolio]

Diagnostic accuracy of hysterosalpingo-foam-sonography to confirm tubal occlusion after Essure(®) placement as treatment for hydrosalpinges.

Consensus globally is that hydrosalpinges need to be treated before IVF owing to their negative influence on outcomes. The current standard treatment is laparoscopic salpingectomy. A potential less in...

A Theoretical study on the placement of microphone arrays for improving the localization accuracy of a fall.

Falling is a common health problem for elderly. To address the problem, we are currently developing an acoustic fall detection system, FADE, which automatically detects a fall and reports to the careg...

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study.

The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through ...

Arrhythmias in children with ventricular assist devices.

Background: Children with decompensated heart failure are at high risk for arrhythmias, and ventricular assist device placement is becoming a more common treatment strategy. The impact of ventricular ...

Accuracy of a flapless protocol for computer-guided zygomatic implant placement in human cadavers: expectations and reality.

This work evaluated the accuracy and safety of a protocol for minimally-invasive flapless zygomatic implant placement that uses computer-guided stereolithographic mucosa-supported surgical templates.

Clinical Trials [3430 Associated Clinical Trials listed on BioPortfolio]

Substudy 'B' of the Accuracy of Ingestible Event Marker (IEM) Detection by the Medical Information Device #1 (MIND1)

The purpose of this study is to determine the accuracy of IEM detection by the MIND1 System by completing a series of Patch applications and IEM ingestions in the clinic.

Development and User Testing of a Decision Aid for Ventricular Assist Device Placement

The goal of this project is to develop a patient-centered decision aid for decision-making about advanced heart failure treatment. This study seeks to create a decision aid that presents o...

Evaluation of the PediGuard™ for Pedicle Screw Insertion

The aim of the study is to determine the relative effectiveness of the PediGuardTM , a device manufactured by SpineVision, Inc, for placement of a pedicle screw pilot (drill) hole and for ...

Essure (Model ESS310) Placement Rate Study

To evaluate the safety and successful placement rate of Essure Model ESS310 device and any factors that may influence the successful placement rate of this device.

Accuracy of the Transpatellar Tendon Approach to Knee Arthrocentesis

The purpose of this study is: - To determine the accuracy of intraarticular placement with the transpatellar tendon approach as compared to the suprapatellar approach. Patients u...

Medical and Biotech [MESH] Definitions

The shifting in position or location of an INTRAUTERINE DEVICE from its original placement.

Removal of a MEDICAL DEVICE from the market due to the identification of an intrinsic property of the device that results in a serious risk to public health.

Planning that has the goals of improving health, improving accessibility to health services, and promoting efficiency in the provision of services and resources on a comprehensive basis for a whole community. (From Facts on File Dictionary of Health Care Management, 1988, p299)

Removal of a MEDICAL DEVICE from the market due to a problem occurring in the manufacture or distribution of the product.

Vaccines used in conjunction with diagnostic tests to differentiate vaccinated animals from carrier animals. Marker vaccines can be either a subunit or a gene-deleted vaccine.

Search BioPortfolio:
Loading
Advertisement

Relevant Topic

Wound management
Latest News Clinical Trials Research Drugs Reports Corporate
Anything that breaks the skin is a wound because when the skin is broken, there's a risk of germs getting into the body and causing an infection. Follow and track Wound Care News on BioPortfolio: Wound Car...

Advertisement

Searches Linking to this Article