A novel device for improving marker placement accuracy.

14:56 EDT 20th April 2014 | BioPortfolio

Summary of "A novel device for improving marker placement accuracy."


BACKGROUND:
Repeatability of marker placement has been acknowledged as a major factor affecting the reliability of multi-segment foot models. A novel device is proposed that is intended to reduce marker placement error and its effect on the reliability of inter-segmental foot kinematic data is investigated.
METHOD:
The novel device was tested on eight healthy subjects. Landmarks were identified and indicated on the subject's foot at the start of testing using pen, and these points were used to guide placement. Markers were twice attached by a podiatrist using a standard approach, and twice by a researcher who used the novel device. Replacement accuracy and the kinematic reliability of the foot model data for both techniques were analysed.
RESULTS:
The mean marker placement variability using the novel device placement device was 1.1mm (SD 0.28) compared to 1.4mm (SD 0.23) when using standard placement techniques. Results suggest that these reductions in placement error tended to improve the overall reliability of the multi-segment data from the foot model.
DISCUSSION:
The novel device is a simple and inexpensive tool for improving the placement consistency of skin-mounted markers.

Affiliation

School of Health, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, United Kingdom.

Journal Details

This article was published in the following journal.

Name: Gait & posture
ISSN: 1879-2219
Pages:

Links

PubMed Articles [7065 Associated PubMed Articles listed on BioPortfolio]

Reduction in radiation during percutaneous lumbar pedicle screw placement using a new device.

Abstract Objective: To assess a new intradermal locator device for percutaneous placement of lumbar pedicle screws. Material and methods: Patients were alternately assigned to two groups. The locator...

Improving accuracy and confidence in distal radius volar plate screw placement through supplemental radiography: examining specialty, education, and experience levels.

The purpose of this study was to assess the extent to which a supplemental radiographic view increases accuracy and confidence ratings when determining screw placement in volar plating of distal radiu...

Comparison of Three-Dimensional Fluoroscopy versus Postoperative Computed Tomography for the Assessment of Accurate Screw Placement after Instrumented Spine Surgery.

While intraoperative three-dimensional fluoroscopy does not possess the resolution and image quality of computed tomography (CT), it may provide adequate information about screw placement to guide int...

Comparing bedside methods of determining placement of gastric tubes in children.

The purpose of this study was to compare the accuracy and predictive validity of pH, bilirubin, and CO2 in identifying gastric tube placement errors in children.

Manual external carotid artery manipulation for failed device advance through the stent in carotid artery stent placement. A technical note.

We report herein the usefulness of a manual external carotid artery manipulation for failed advancement of devices through the stent in carotid artery stent (CAS) placement with open cell type stent a...

Clinical Trials [3013 Associated Clinical Trials listed on BioPortfolio]

Evaluation of the PediGuard™ for Pedicle Screw Insertion

The aim of the study is to determine the relative effectiveness of the PediGuardTM , a device manufactured by SpineVision, Inc, for placement of a pedicle screw pilot (drill) hole and for...

Accuracy of the Transpatellar Tendon Approach to Knee Arthrocentesis

The purpose of this study is: - To determine the accuracy of intraarticular placement with the transpatellar tendon approach as compared to the suprapatellar approach. Patients u...

Nickel Allergy With Septal Closure Devices

This study is for patients who have been diagnosed with either a Patent Foramen Ovale [PFO] or an Atrial Septal Defect [ASD]. These are a type of hole located in the wall that separates t...

Study of Robotic Template Guidance for Needle Placement in Transperineal Prostate Brachytherapy

This is a study that will try see if a device can help to better guide the needle that places prostate cancer treatment.

Evaluating Outcomes in the Placement of Boomerang Percutaneous Device

The purpose of this study is to evaluate the safety and effectiveness of the Boomerang percutaneous closure device following diagnostic cerebral angiography or neurointerventional procedur...

Medical and Biotech [MESH] Definitions

The shifting in position or location of an INTRAUTERINE DEVICE from its original placement.

Removal of a MEDICAL DEVICE from the market due to the identification of an intrinsic property of the device that results in a serious risk to public health.

Planning that has the goals of improving health, improving accessibility to health services, and promoting efficiency in the provision of services and resources on a comprehensive basis for a whole community. (From Facts on File Dictionary of Health Care Management, 1988, p299)

Removal of a MEDICAL DEVICE from the market due to a problem occurring in the manufacture or distribution of the product.

Vaccines used in conjunction with diagnostic tests to differentiate vaccinated animals from carrier animals. Marker vaccines can be either a subunit or a gene-deleted vaccine.

Search BioPortfolio:
Advertisement
Advertisement