The Optimization of Blood Pressure and Fluid Status Control With Eight-Polar Bioelectrical Impedance Analysis
Summary
Peritoneal dialysis (PD) is a widely used modality of renal replacement therapy. Due to its continuous nature of therapy, better control of fluid status and preservation of residual renal function were presumed by most nephrologists. However, recent evidences showed that it might not be the case. The severity of fluid overloading and the need for anti-hypertensive agents to control blood pressure seems to be more severe for PD patients. Therefore, more aggressive strategy to control dry weight is mandatory in PD patients. However, over reduction of dry weight might affect residual renal function (RRF) and, probably, the survival of PD patients. A balance between reduction of dry weight and preservation of RRF is crucial for the care of PD patients. Currently, only clinical measures like cardiothoracic ratio on chest X-ray and absence of pedal edema were used to evaluate PD patient's dry weight. There is no objective method to determine dry weight accurately. In this prospective and randomized study, the investigators will use multi-frequency bio-impedance (MF-BIA) to detect intracellular and extracellular water (ECW) content of patients.
Study Design
Allocation: Randomized, Control: Placebo Control, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
Conditions
Hypertension
Intervention
Bioelectrical impedance-guide dry weight reduction
Location
Taipei Veterans General Hospital
Taipei
Taiwan
112
Status
Completed
Source
Taipei Veterans General Hospital,Taiwan
Results (where available)
Links
- Source: http://clinicaltrials.gov/show/NCT00852514
- Information obtained from ClinicalTrials.gov on July 15, 2010
Medical and Biotech [MESH] Definitions
Cardiography, Impedance
A type of impedance plethysmography in which bioelectrical impedance is measured between electrodes positioned around the neck and around the lower thorax. It is used principally to calculate stroke volume and cardiac volume, but it is also related to myocardial contractility, thoracic fluid content, and circulation to the extremities.
Acoustic Impedance Tests
Objective tests of middle ear function based on the difficulty (impedance) or ease (admittance) of sound flow through the middle ear. These include static impedance and dynamic impedance (i.e., tympanometry and impedance tests in conjunction with intra-aural muscle reflex elicitation). This term is used also for various components of impedance and admittance (e.g., compliance, conductance, reactance, resistance, susceptance).
Plethysmography, Impedance
Recording changes in electrical impedance between electrodes placed on opposite sides of a part of the body, as a measure of volume changes in the path of the current. (Stedman, 25th ed)
Bariatric Medicine
The discipline concerned with WEIGHT REDUCTION in patients with OBESITY.
Rna Editing
A process that changes the nucleotide sequence of mRNA from that of the DNA template encoding it. Some major classes of RNA editing are as follows: 1, the conversion of cytosine to uracil in mRNA; 2, the addition of variable number of guanines at pre-determined sites; and 3, the addition and deletion of uracils, templated by guide-RNAs (RNA, GUIDE).
Clinical Trials
Comparison Study for Bioelectrical Impedance Device to Measure Human Body Composition
The purpose of this study is to determine if the ElectroFluidGraph(tm) (EFG) impedance analyzer is comparable to a predicate device in measuring human body composition.
The Effects of Nebivolol on Aortic Impedance Parameters in Type 2 Diabetes (The Effort Trial)
To examine changes in aortic impedance in patients on nebivolol vs. metoprolol succinate in Type 2 hypertensive diabetic patients as measured by the change from baseline in central systoli...
CRT-D Based Impedance Monitoring Study
The intent of this feasibility study is to collect and analyze intra-thoracic impedance measurements from a CRT-D device in a heart failure population.
Hypertension Prevention Trial (HPT) Feasibility Study
To test the feasibility and the efficacy of nutritional interventions in the primary prevention of hypertension in individuals predisposed to the development of hypertension; specifically,...
Detect Fluid Early From Intra-Thoracic Impedance Monitoring
To demonstrate the safety and effectiveness of the Impedance Monitoring Feature in St Jude Medical cardiac devices.
PubMed Articles
BACKGROUND: Validated equations for body composition analysis using bioelectrical impedance (BIA) in morbidly obese (MO) subjects are scarce. Thus, our aim was to develop new equ...
Abstract Background: Several techniques are currently used for measurement of body composition. Bioelectrical impedance assessment (BIA) is a simple, noninvasive method of assessing body composition....
Accurate assessment of neonatal body composition is essential to studies investigating neonatal nutrition or developmental origins of obesity. Bioelectrical impedance analysis or bioimpedance analysis...
Esco, MR, Olson, MS, Williford, HN, Lizana, SN, and Russell, AR. The accuracy of hand-to-hand bioelectrical impedance analysis in predicting body composition in college-age female athletes. J Strength...
Bioelectrical impedance analysis in clinical practice: implications for hepatitis C therapy.
ABSTRACT: BACKGROUND: Body composition analysis using phase angle (PA), determined by bioelectrical impedance analysis (BIA), reflects tissue electrical properties and has prognostic value in liver ci...