Advertisement

Effect of Nephral 400 ST Dialysis Membrane on Coagulation in Hemodialysis

16:21 EDT 18th May 2013 | BioPortfolio

Summary

The purpose of this study is to investigate whether the dialysis filter AN69ST (Nephral 400 ST Dialysis Membrane) induces less clotting during hemodialysis than a conventional polysulphone filter. Our hypothesis is that the two filters induce the same degree of clotting.

Description

Six consecutive hemodialysis (HD) sessions are evaluated per patient, altogether 10 - 12 stable HD patients (or at least 48 HD sessions altogether). During these six sessions, AN69ST and Fx8 are used on alternate days. Dalteparin is given intravenously as a single bolus dose at start of HD (50% of the conventional dose). Clinical clotting is evaluated visually each hour of HD after blood draining of the venous air trap: 1=no clot, 2=a fibrinous ring, 3=a clot <1 cm, 4=a clot >1 cm and 5=coagulated system (stop in HD).

Blood specimens are taken at start and after each hour of HD. Markers of coagulation (prothrombin 1+2) and of platelets (beta-thromboglobulin) are evaluated as well as anti FXa-activity.

The two filters are going to be compared statistically with respect to the degree of clinical clotting and of intravascular coagulation and platelets activation.

Study Design

Allocation: Non-Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Open Label, Primary Purpose: Prevention

Conditions

Extracorporeal Clotting During Hemodialysis

Intervention

AN69ST dialysis membrane, Fx8 (Fresenius)

Location

Department of Nephrology, Ullevål University Hospital
Oslo
Norway
0407

Status

Completed

Source

Ullevaal University Hospital

Results (where available)

View Results

Links

Medical and Biotech [MESH] Definitions

Renal Dialysis

Therapy for the insufficient cleansing of the BLOOD by the kidneys based on dialysis and including hemodialysis, PERITONEAL DIALYSIS, and HEMODIAFILTRATION.

Hemodialysis Solutions

Solutions prepared for hemodialysis. The composition of the pre-dialysis solution may be varied in order to determine the effect of solvated metabolites on anoxia, malnutrition, acid-base balance, etc. Of principal interest are the effect of the choice of buffers (e.g., acetate or carbonate), the addition of cations (Na+, K+, Ca2+), and addition of carbohydrates (glucose).

Hemodialysis Units, Hospital

Hospital units in which care is provided the hemodialysis patient. This includes hemodialysis centers in hospitals.

Dialysis Solutions

Solutions prepared for exchange across a semipermeable membrane of solutes below a molecular size determined by the cutoff threshold of the membrane material.

Peritoneal Dialysis, Continuous Ambulatory

Portable peritoneal dialysis using the continuous (24 hours a day, 7 days a week) presence of peritoneal dialysis solution in the peritoneal cavity except for periods of drainage and instillation of fresh solution.

Clinical Trials [ 509 Associated Clinical Trials listed on BioPortfolio]

Ease of Use and Blood Clotting for the Gambro Polyflux HD-C4 Big Dialyzer

The purpose of this study is to collect information on the ease of use and thrombogenicity of the Polyflux HD-C4 Big and Fresenius Optiflux 180NR or 200NR dialyzers under conditions of rou...

Chronic Hemodialysis Without Systemic Heparinization : a Randomized Study

Conventional hemodialysis requires transient systemic anticoagulation to prevent blot clotting after contact with the extracorporeal circuit. However, low molecular weight heparin (LMWH) o...

Study of Inflammation and Oxidative Stress in Persons Undergoing Dialysis

Little is known about how some drugs affect inflammation or clotting factors in people receiving hemodialysis. It is not yet known if these drugs help prevent heart damage as they do in pe...

Study of beta2-Microglobulin Removal by Standard Versus New High Cut-Off Haemodialysis Membrane

The purpose of this study is to determine whether a novel haemodialysis membrane, compared with the standard dialysis membrane, will increase the removal of beta2-microglobulin in chronic...

The Effect of Different Dosages of Solute Clearance on Outcome in Twice Weekly Hemodialysis Patients

Adequacy of solute clearance makes a profound impact on clinical outcome in maintenance hemodialysis patients. Thus far, guidelines on the target of solute clearance (Kt/V or URR) are base...

PubMed Articles [ 7532 Associated PubMed Articles listed on BioPortfolio]

Blood leak alarm interference by hydoxocobalamin is hemodialysis machine dependent.

Context. Hydroxocobalamin has been reported to interfere with the blood leak alarm on hemodialysis machines making it difficult to use this treatment modality after hydroxocobalamin infusion. Objectiv...

Removal of doripenem during hemodialysis and the optimum dosing regimen for patients undergoing hemodialysis.

The removal of doripenem by hemodialysis was studied in six hemodialysis patients. Following an intravenous drip infusion of 0.5 g of doripenem, plasma concentrations of the drug were measured. The...

The Safety of Low-Potassium Dialysis.

Patients with kidney failure depend on dialysis to maintain neutral potassium balance. The amount of potassium removed during a hemodialysis treatment is inversely proportional to the potassium concen...

Long-term effects of daily hemodialysis on vascular access outcomes: A prospective controlled study.

Daily hemodialysis has been associated with surrogate markers of improved survival among hemodialysis patients. A potential disadvantage of daily hemodialysis is that frequent vascular access cannulat...

Do Clinical Outcomes in Chronic Hemodialysis Depend on the Choice of a Dialyzer?

Nephrologists are presented with a range of choices when selecting a dialyzer for chronic hemodialysis. Dialyzers differ in the material, structure, permeability and surface area of their membrane, an...

More From BioPortfolio on "Effect of Nephral 400 ST Dialysis Membrane on Coagulation in Hemodialysis"

Search BioPortfolio: