Cervical cancer remains a significant cause of morbidity and mortality in women worldwide and is the leading cause of cancer-related death in Botswana. It is well established that women with HIV have a higher risk of persistent HPV infection leading to cervical cancer. We assessed HPV prevalence and genotype distribution in 126 tissue specimens from confirmed invasive cervical cancer cases using A...

Performance evaluation of new Abbott Alinity hq hematology analyzer.

Abbott Alinity hq is a next-generation automated hematology analyzer providing complete blood count (CBC) with 6-part white blood cells (WBC) differential counts. The purpose of this study was to evaluate the performance of the analyzer to verify the diagnostic and clinical utility of the Abbott Alinity hq automated system.

ANNALS EXPRESS: Multicenter evaluation of the Roche Elecsys® Active B12 (holotranscobalamin) electro-chemiluminesence immunoassay.

Background Vitamin B12 deficiency is a common disorder. In circulation, vitamin B12 is bound to transcobalamin (holotranscobalamin), which is considered the active form of cobalamin. The objective of this study was to evaluate the analytical performance of the Roche Elecsys Active B12 immunoassay. Methods Limit of quantification and linearity were assessed according to CLSI EP17-A2 and EP-6A guide...

Hydrocolloid blister plaster decreases allergic contact dermatitis to Freestyle libre and isobornyl acrylate.

Our patient, a 12 year-old boy, known with diabetes mellitus type 1 since 6 years, started usage of the Flash Glucose Monitoring system (iscCGM; Freestyle Libre, Abbott) in June 2016 (Figure 1a). In November 2016 he complained the first time about itch underneath his glucose sensor, which progressively worsened, so that after some days the sensor had to be removed. This article is protected by cop...

Evaluation of the Abbott RealTime quantitative CMV and EBV assays using the maxCycle protocol in a laboratory automation context.

Real-time PCR are often used for the diagnosis and monitoring of Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) infections in susceptible populations. In this context, we evaluated the analytical performances of the Abbott RealTime CMV/EBV maxCycle protocol automated on the m2000 platform (Abbott). It was compared to our routinely-used procedure consisting of a NucleoMag® DNA extraction autom...

Incidence, Characterization, and Clinical Impact of Device-Related Thrombus Following Left Atrial Appendage Occlusion in the Prospective Global AMPLATZER Amulet Observational Study.

The study sought to report the incidence, characteristics, and clinical impact of device-related thrombus (DRT) following left atrial appendage occlusion (LAAO) with the AMPLATZER Amulet device (Abbott, Plymouth, Minnesota).

Clinical Outcomes in Patients with Severe Aortic Valve Stenosis Treated with a Portico Transcatheter Aortic Valve System.

The Portico™ transcatheter aortic valve implantation (TAVI) system (Abbott Vascular, Santa Clara, CA, USA) was specifically designed to reduce some of the limitations associated with first-generation TAVI devices. Most of the currently available clinical evidence was obtained from randomized studies that compared TAVI to aortic valve replacement using first-generation transcatheter heart valve d...

Advertising Abbott's Pentothal from Antarctica to Toledo: A Bolus for Bowlus?

Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay.

Siemens Healthcare Diagnostics has four commercially available assays on different analytical platforms using different methodologies to generate signal. We assessed the analytical performance of the Dimension EXL hs-cTnI assay (LOCI method) across different matrices and compared it to two different acridinium ester-based hs-cTnI assays (ADVIA Centaur and Abbott ARCHITECT).

Evaluation of Elecsys HTLV-I/II assay in comparison with ARCHITECT rHTLV-I/II assay with Korean samples.

The seroprevalence rate of human T-lymphotropic virus I and II (HTLV-I/II) in Korean blood donors has been known as 0.004%, and HTLV-I/II Ab screening test has been performed since 2008 in Korea. Korea Ministry of Food and Drug Safety (MFDS) approved two chemiluminescent microparticle immunoassays (CMIA) for testing HTLV-I/II antibody, ABBOTT PRISM HTLV-I/HTLV-II and ARCHITECT rHTLV-I/II. A multic...

Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes.

Real-time continuous glucose monitoring (CGM) devices help detect glycemic excursions associated with exercise, meals, and insulin dosing in patients with type 1 diabetes (T1D). However, the delay between interstitial and blood glucose may result in CGM underestimating the true change in glycemia during activity. The purpose of this study was to examine CGM discrepancies during exercise and the me...

Risk stratification of HIV infection for patients needing molecular confirmation with the Abbott 4th generation Architect System.

Some patients need their 4 generation HIV testing results confirmed with molecular testing after primary confirmatory testing which may not be immediately available. Further risk stratification of these patients pending the results of molecular testing may be of value not only for patient counseling but also for treatment of women in labor.

Adverse Event Profile Associated with Prolonged Use of CentriMag Ventricular Assist Device for Refractory Cardiogenic Shock.

Several studies have investigated early outcomes with a surgical short-term ventricular assist device (VAD), but little is known about adverse event profile during prolonged support with a surgical short-term VAD. This is a retrospective analysis of 161 patients who received a CentriMag ventricular assist system (Abbott Laboratories, Abbott Park, IL) at our institution between January 2007 and Jun...

Echocardiographic guidance for transcatheter mitral valve repair using edge-to-edge clip.

Percutaneous intervention for mitral valve disease has been established as an alternative to open surgical repair in high risk and inoperable candidates. Edge-to-edge leaflet plication with Mitraclip (Abbott, Menlo Park, CA, USA) is indicated for primary and secondary mitral valve diseases. Echocardiography provides a better understanding of mitral valve anatomy and allows us to classify and quant...

Evaluation of the Abbott ARCHITECT™ cytomegalovirus IgM/IgG, rubella IgM/IgG, and syphilis treponemal antibodies enzyme immunoassays in a mother and child health center population.

This study evaluated the concordance of Architect™ chemiluminescent microparticle immunoassays with Captia™ ELISA for cytomegalovirus (CMV) IgM and IgG, with Enzygnost™ and Captia™ ELISA for rubella IgM and IgG and with Trep-Sure™ ELISA for syphilis treponemal antibodies in a mixed pediatric and obstetrical population. Total agreement between assays and Kappa statistic value were 82.5% (...

Prevalence of high-risk human papilloma virus in women with high-grade squamous cell intraepithelial lesions in Botswana using Abbott RealTime HPV assay.

High-risk human papillomavirus (HR-HPV) has been demonstrated to be the necessary cause of cervical carcinoma. High-risk HPV detection has a prognostic significance for the women who are at increased risk of disease progression. HPV genotyping in cervical cancer precursor lesions is crucial for prevention and management of cervical cancer. This study was designed to investigate the distribution of...

Comparison of analytical performances of the Roche Cobas 6800 CT/NG assay with the Abbott m2000 Real Time CT/NG assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae.

The Roche Cobas 6800 CT/NG assay was compared to the Abbott m2000 Real Time CT/NG assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae in 714 specimens referred to the bacteriology laboratory at Geneva University Hospitals, between November 2017 and March 2018, and in nine external quality controls for molecular diagnostics (seven from QCMD Glasgow and two from UK NEQAS). For C. tra...

Early clinical results with the Tendyne transcatheter mitral valve replacement system.

Transcatheter mitral valve replacement is an emerging technology for the treatment of mitral valve regurgitation. Numerous devices are in development and in various stages of clinical investigation. The Tendyne system (Tendyne Holdings, LLC, a subsidiary of Abbott Vascular, Roseville, Minnesota) is a fully repositionable and retrievable, transapical transcatheter mitral valve replacement platform....

Influencing cytomegalovirus DNA load measurements in whole blood and plasma specimens from allogeneic hematopoietic stem cell transplant recipients.

We assessed the impact of several parameters, including the nature of the episode of Cytomegalovirus (CMV) DNAemia, the use of preemptive antiviral therapy, and the blood cell content in CMV DNA loads measured in whole blood (WB) and plasma (PL). CMV DNA load was quantified in 245 paired specimens collected within 43 postengraftment episodes of CMV DNAemia by using the CMV RealTime CMV PCR (Abbott...