CPDA-1 Blood Collection Set with Sampling System

Instruction for Use for Systems Containing a Y Sampling Site (YSS) or Sample Diversion Pouch (with or without a pre-attached SampLok® Vacuum Tube Holder). Refer to unit foil package label for specific product description being used.

Sterile, nonpyrogenic fluid path. Sterilized by steam.

Rx only.

This product is free of natural rubber latex.

For collection of blood and preparation of red blood cells, plasma and platelets. Platelets are not intended to be produced when using ‘doubles’.

Failure to achieve and maintain a closed system during processing would result in a product that must be transfused within 24 hours.

Use Aseptic Technique.

Use only if solution is clear.

If preparing a platelet concentrate, the platelet-rich plasma should be separated from the red blood cells within 8 hours after blood collection.

If preparing fresh frozen plasma, separate from the red blood cells and place in the freezer at -18 °C or colder within 8 hours after collection.

Store CPDA-1 preserved red blood cells at 1—6 °C for up to 35 days and use as indicated.

* During processing, always observe the following precautions:

1. Sealing should be done in a manner that avoids fluid splatter.

2. Always dispose of blood-contaminated products in a manner consistent with established BIOHAZARD safety procedures.

There are no known potential adverse reactions associated specifically with the CPDA-1 Blood Collection Set with Sampling System.

1. Load blood agitation device or suspend blood bag on donor scale and adjust donor scale to desired collection gross weight as per manufacturer's instructions.

2. Clamp donor tubing between the DonorCare® Needle Guard (DCNG) and Y Sampling Site.

3. Secure donor tubing above the Y connector and disinfect site of phlebotomy.

4. If using blood pressure cuff, inflate to not more than 60 mm Hg.

5. Remove donor needle cover and accomplish phlebotomy.

6. Release clamp and ensure there is blood flow. Reduce pressure as required.

7. Slide the DCNG midway over the needle hub and securely tape DCNG to the donor's arm as close to the top of the DCNG as possible. Note: If blood flow is slow, slide DCNG away from the needle hub, adjust and re-engage DCNG. If repeated needle adjustment is necessary, slide DCNG away from the needle hub and re-engage at the end of blood collection.

8. Collect appropriate volume of blood into collection bag, as indicated on packaging.

Note: Mix blood and anticoagulant frequently during collection, for example, once every 45 seconds, and immediately after collection. If blood agitation device is used, follow manufacturer's operating instructions.

9. After required amount of blood has been collected, seal donor tubing between Y Sampling Site and the collection bag.*

10. For blood sampling, remove the Y Sampling Site needle cover. Ensure the protective sheath is in place over the sampling needle.

11. Fasten the vacuum tube holder on to the base of the sampling needle.

12. Collect blood samples into vacuum tubes.

13. Ensure the vacuum tubes are centered within the vacuum tube holder during sample collection.

14. Maintain forward pressure on the vacuum tubes during sample collection.

Note: After the last tube is collected, it is recommended that the vacuum tube holder be left in place.

15. After blood samples are collected, clamp donor tubing between the Y Sampling Site and DCNG, as close as possible to the DCNG.

16. Release any remaining pressure from the donor's arm.

17. DCNG must be held stationary while the needle is withdrawn into it. While holding sides of DCNG near the front, grasp the tubing below the clamp and pull the needle into the DCNG until it locks into place, and the needle hub engages the bottom of the DCNG.

18. Insert the DCNG into the vacuum tube holder. Note: It is recommended that the DCNG be inserted securely into the vacuum tube holder prior to discarding.

19. Seal donor tubing adjacent to DCNG.* Detach and discard needle, DCNG, Y Sampling Site and tubing.*

20. Strip tubing between seal and collection bag.

21. Continue to “Processing Instructions”, Section IV, Step 1.

When using systems with a pre-attached SampLok vacuum tube holder, follow instructions as noted below, but refer to Section III when indicated to do so.

1. Load blood agitation device or suspend blood bag on donor scale and adjust donor scale to desired collection gross weight as per manufacturer's instructions.

2. Clamp donor tubing between the DonorCare® Needle Guard (DCNG) and Sampling Site.

3. Secure donor tubing above the Y connector and disinfect site of phlebotomy.

4. If using blood pressure cuff, inflate to not more than 60 mm Hg.

5. Remove donor needle cover and accomplish phlebotomy.

6. Release clamp and ensure there is blood flow.

7. Slide the DCNG midway over the needle hub and securely tape DCNG to the donor's arm as close to the top of the DCNG as possible. Note: If blood flow is slow, slide DCNG away from the needle hub, adjust and re-engage DCNG. If repeated needle adjustment is necessary, slide DCNG away from the needle hub and re-engage at the end of blood collection.

8. The donor blood will be automatically diverted to the sample diversion pouch. Once the sample diversion pouch is filled, close clamp immediately on tubing between the sample diversion pouch and Y connector. Warning: To avoid risk of air embolism to donor, do not squeeze sample diversion pouch while tubing is open.

9. Open snap-open closure between the Y connector and the collection bag to initiate blood collection. Reduce pressure as needed.

10. Permanently seal tubing between the sample diversion pouch and the Y connector to maintain sterility of the system prior to collecting blood samples.* Note: When using systems with a pre-attached SampLok vacuum tube holder, go to Section III.

11. For blood sampling, remove the Sampling Site needle cover. Ensure the protective sheath is in place over the sampling needle.

12. Fasten the vacuum tube holder on to the base of the sampling needle.

13. Position the sample diversion pouch downwards so that the air rises to the top of the pouch and away from the vacuum tube holder. Note: Drawing air into the vacuum tube may cause hemolysis.

14. Collect blood samples from the sample diversion pouch into vacuum tubes within approximately four minutes to avoid possible clot formation.

15. Ensure the vacuum tubes are centered within the vacuum tube holder during sample collection.

16. Maintain forward pressure on the vacuum tubes during sample collection.

Note: After the last tube is collected, it is recommended that the vacuum tube holder be left in place.

17. Collect appropriate volume of blood into collection bag as indicated on packaging.

Note: Mix blood and anticoagulant frequently during collection, for example, once every 45 seconds, and immediately after collection. If blood agitation device is used, follow manufacturer's operating instructions.

18. After required amount of blood has been collected, seal donor tubing close to snap open closure.*

19. Clamp donor tubing between the Y connector and DCNG, as close as possible to the DCNG.

20. Release any remaining pressure from the donor's arm.

21. DCNG must be held stationary while the needle is withdrawn into it. While holding sides of DCNG near the front, grasp the tubing below the clamp and pull the needle into the DCNG until it locks into place, and the needle hub engages the bottom of the DCNG.

22. Insert the DCNG into the vacuum tube holder, if desired. Note: It is recommended that the DCNG be inserted securely into the vacuum tube holder prior to discarding.

23. Seal donor tubing adjacent to DCNG.* Detach and discard needle, DCNG, sample diversion pouch and tubing.*

24. Strip tubing between seal and collection bag.

25. Continue to "Processing Instructions", Section IV, Step 1.

1. To collect blood samples, open lid from SampLok vacuum tube holder.

2. Open snap-open closure between sample diversion pouch and SampLok vacuum tube holder.

3. Position the sample diversion pouch downwards so that the air rises to the top of the pouch and away from the SampLok vacuum tube holder. Note: Drawing air into the vacuum tube may cause hemolysis.

4. Collect blood samples from the sample diversion pouch into vacuum tubes within approximately four minutes to avoid possible clot formation.

5. Ensure the vacuum tubes are centered within the SampLok vacuum tube holder during sample collection.

6. Maintain forward pressure on the vacuum tubes during sample collection.

7. The lid may be closed on the SampLok vacuum tube holder after sample collection.

8. Return to Section II, Step 17. Note: When collection of unit is complete and the donor needle is engaged in the DCNG, open the lid of the SampLok vacuum tube holder and insert the DCNG into the holder. Twist until it locks into place. An audible click will confirm that it is locked.

1. If desired, seal at or adjacent to "X" marks on the tubing to provide numbered segments of anticoagulated blood for typing or crossmatching.*

2. Load whole blood and remaining bags into centrifuge cup, ensuring that the tubing stays in the top half of the cup.

3. Centrifuge at conditions designed to produce desired components.

4. Carefully remove the unit from the centrifuge and place the collection bag in the plasma expressor.

5. Clamp tubing to extra satellite bag(s), if present.

6. Gently apply expressor pressure.

7. Open snap-open closure on collection bag and express plasma.

8. After plasma is expressed, clamp tubing between satellite bag(s) whole blood bag and release expressor pressure.

9. Seal tubing and detach the bag containing packed red cells, and set aside plasma for further processing.*

10. Gently mix packed red cells.

11. Store CPDA-1 preserved red blood cells at 1—6 °C for up to 35 days and use as indicated.

Each shipping case contains 8 foil envelopes. Within each foil envelope resides 3 units of the collection system. Each unit consists of a collection bag with 63 ml of CPDA-1 solution and one empty bag.

Envelope Label

Collection Bag Label

Plasma Bag Label

HAEMONETICS and THE Blood Management Company are trademarks of Haemonetics Corporation.

DonorCare and SampLok are registered trademarks of ITL Corporation, Canberra, Australia.

Manufactured for:

Haemonetics Corporation

400 Wood Road

Braintree, MA 02184, USA

By: Haemonetics Manufacturing Inc.

1630 Industrial Park Street

Covina, CA 91722, USA

www.haemonetics.com

800-537-2802

IFU P/N 147130924

Manufacturer

Haemonetics Manufacturing Inc

Active Ingredients

Source

Drugs and Medications [99 Associated Drugs and Medications listed on BioPortfolio]

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) Blood-Pack Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Clinical Trials [10094 Associated Clinical Trials listed on BioPortfolio]

Evaluation of Whole Blood With CPD Anticoagulant and AS-7/SOLX Additive Solution

This study will evaluate a new blood collection and filtration system that is intended to be used to collect, filter, separate and store red blood cells and, separately, plasma. The new b...

Performance Evaluation of the Nanomix eLab® CRP, PCT, and LAC Assays With the Nanomix eLab System

The performance of the eLab C-Reactive Protein, Procalcitonin, and Lactate Assays will be demonstrated during a method comparison study in which prospectively collected venous whole blood ...

Blood Sample Collection in Subjects With Pulmonary Nodules or CT Suspicion of Lung Cancer or Pathologically Diagnosed Lung Cancer

The primary objective of this study is to obtain de-identified, clinically characterized, whole blood specimens for use in assessing new biomarkers for the detection of neoplasms of the lu...

Prospective Collection Tissue Research Protocol

This study aims to collect matched donor tissue and blood to enable the development of a manufacturing process for potential immunotherapies.

Collection of Immunology Specimens From Patients With Cancer or Blood Disorders, and Healthy Volunteers

This research trial collects and stores blood, tissue, and bone marrow specimens from patients with cancer or blood disorders, and healthy volunteers to study the immune system in a variet...

PubMed Articles [15359 Associated PubMed Articles listed on BioPortfolio]

Computational comparative mechanistic study of C-E (E=C,N,O,S) couplings via CO2 activation mediated by uranium(III) complexes.

We report a DFT mechanistic study on the functionalization of CO2 to form C-C, C-N, C-S, and C-O bonds promoted by trivalent uranium complexes (Tp)2UR [Tp = hydrotris(3,5-dimethylpyrazolyl)-borate lig...

An update on the GLOB blood group system (and former GLOB collection).

The main change that has occurred in the GLOB blood group system since the GLOB review published in this journal in 2013 is the addition of an antigen. The high-prevalence PX2 antigen, originally reco...

Evaluation of Specimen Types for Pima CD4 Point-of-Care Testing: Advantages of Fingerstick Blood Collection into an EDTA Microtube.

Effective point-of-care testing (POCT) is reliant on optimal specimen collection, quality assured testing, and expedited return of results. Many of the POCT are designed to be used with fingerstick ca...

Is a discard tube necessary, when drawing blood for P-Ionized calcium analysis?

Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The procedure of venous blood collection for ionized calc...

Synthesis, characterization and antibacterial activity of Zn(II) coordination polymer.

In this study, the zinc(II)-based coordination polymer, [Zn(CPDA)(NO))](CPDA = 1,2-cyclopentanedicarboxylic acid) (1), had been successfully synthesized according to the hydrothermal method. After...

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topic

Blood
Blood is a specialized bodily fluid that delivers necessary substances to the body's cells (in animals) – such as nutrients and oxygen – and transports waste products away from those same cells.  In vertebrates, it is composed of blo...


Drugs and Medication Quicklinks


Searches Linking to this Drug Record