Rx Only

Integral Donor Tube (IDT)

Use aseptic technique.

Caution: Do not use unless the solutions are clear.

NOTE:

In order to establish fluid transfer from primary container to secondary system, hold the cannula by its base with one hand, and with the other hand break the cannula by bending it 90º in one direction, then 180º in the opposite direction (Figure 6).

For further processing, use standard component processing and storage techniques.

Dispose of containers and materials into appropriate biohazardous waste containers following established procedures.

Sterile, non-pyrogenic fluid path. Steam sterilized. Single use only.

Store at Controlled Room Temperature.

USP Definition of “Controlled Room Temperature” United States Pharmacopeia, General Notices.United States Pharmacopeial Convention, Inc.12601 Twinbrook Parkway, Rockville, MD

Manufacturer

Manufactured by: Fenwal International, Inc. Road 357, Km. 0.8Maricao, PR 00606

Made in USA

Imported and distributed in India by: Fenwal India Pvt Ltd Upper Ground Floor, Tower BDLF Building No. 10, DLF Cyber CityDLF Phase-II, Gurgaon 122 002,Haryana, IndiaImport License No.: FF-504-14890

Imported and distributed in Indonesia by: PT.Medquest Jaya Global Menara Salemba 6th FloorJl.Salemba Raya Kav 5-5AJakarta-Indonesia 10440Reg. No.: DEPKES RI AKL 20209902358

Imported and distributed in Thailand by: Fenwal (Thailand) Ltd. 17th Fl. Thanapoom Tower,1550 New Petchburi Rd., MakasanRajthevi, Bangkok 10400Thailand

Imported and distributed in Venezuela by: SOLUCARE GT, C.A. RIF J-30512494-9 en La Urbina, Caracas,Republica Bolivariana de VenezuelaTELF (0212) 2436663Registrado en el MPPS bajo el No:

07-19-07-227 REV: A 05/2012

FENWAL and BLOOD-PACK are trademarks of Fenwal, Inc.

© 2012 Fenwal, Inc. All rights reserved.

Code T4R1339UT

6 Units

Fenwal™

Triple BLOOD-PACK™ Unit Anticoagulant Citrate Phosphate Dextrose Adenine Solution (CPDA-1)

Rx only

Triple BLOOD-PACK™ unit for collection of 350 mL of blood, 16 gauge needle.

Each unit consists of a primary container with 49 mL CPDA-1 solution containing 1.56 g Dextrose (monohydrate), USP, 1.29 g Sodium Citrate (dihydrate), USP, 160 mg Citric Acid (monohydrate), USP, 109 mg Monobasic Sodium Phosphate (monohydrate), USP, 13.5 mg Adenine, USP, Water for Injection USP to 49 mL, and two empty 400 mL TRANSFER PACK™ containers.

See instructions for use. Sterile, non-pyrogenic fluid path. Steam sterilized. Single use only. Do not vent. Do not use if there is any visible sign of deterioration. Dispose of container appropriately.

Store at Controlled Room Temperature (refer to direction insert).

Manufactured by: Fenwal International, Inc. Road 357, Km. 0.8Maricao, PR 00606

Made in USA

07-28-04-648 REV: A

Imported and distributed in Thailand by: Fenwal (Thailand) Ltd. 17th Fl. Thanapoom Tower1550 New Petchburi Rd., MakasanRajthevi, Bangkok 10400ThailandReg. No.: See Instructions for use.

Imported and distributed in Indonesia by: PT. Medquest Jaya Global Menara Salemba 6th FloorJl.Salemba Raya Kav 5-5AJakarta-Indonesia 10440Reg. No.: DEPKES RI AKL 20209902358

FENWAL, BLOOD-PACK, and TRANSFER PACK are trademarks of Fenwal, Inc.

Manufacturer

Fenwal, Inc.

Active Ingredients

Source

Drugs and Medications [38 Associated Drugs and Medications listed on BioPortfolio]

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) Blood-Pack Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Cpda-1 [fenwal, inc.]

Anticoagulant Citrate Phosphate Dextrose Adenine Solution, USP (CPDA-1) BLOOD-PACK™ Unit

Clinical Trials [0 Results]

None

PubMed Articles [2 Associated PubMed Articles listed on BioPortfolio]

Computational comparative mechanistic study of C-E (E=C,N,O,S) couplings via CO2 activation mediated by uranium(III) complexes.

We report a DFT mechanistic study on the functionalization of CO2 to form C-C, C-N, C-S, and C-O bonds promoted by trivalent uranium complexes (Tp)2UR [Tp = hydrotris(3,5-dimethylpyrazolyl)-borate lig...

Synthesis, characterization and antibacterial activity of Zn(II) coordination polymer.

In this study, the zinc(II)-based coordination polymer, [Zn(CPDA)(NO))](CPDA = 1,2-cyclopentanedicarboxylic acid) (1), had been successfully synthesized according to the hydrothermal method. After...

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topics

Collaborations in biotechnology
Commercial and academic collaborations are used throughout the biotechnology and pharmaceutical sector to enhance research and product development. Collaborations can take the form of research and evaluation agreements, licensing, partnerships etc. ...

Nutrition
Within medicine, nutrition (the study of food and the effect of its components on the body) has many different roles. Appropriate nutrition can help prevent certain diseases, or treat others. In critically ill patients, artificial feeding by tubes need t...


Drugs and Medication Quicklinks


Searches Linking to this Drug Record