Advertisement

Topics

HYDROCORTISONE CREAM, USP 1% HYDROCORTISONE OINTMENT, USP 1% TOPICAL CORTICOSTEROID Rx Only | Procto-Pak [Rising Pharmaceuticals, Inc.] | BioPortfolio

13:34 EST 27th January 2019 | BioPortfolio

Note: While we endeavour to keep our records up-to-date one should not rely on these details being accurate without first consulting a professional. Click here to read our full medical disclaimer.

The topical corticosteroids constitute a class of primarily synthetic steroids used as antiinflammatory and anti-pruritic agents. Hydrocortisone is included in this class of synthetic corticosteroid.

Chemically, hydrocortisone is Pregn-4-ene-3,20-dione,11,17,21-trihydroxy-,(11ß)- its molecular formula is CHO; its molecular weight is 362.46; its Chemical Abstract Service (CAS) registry number is 50-23-7; and its structural formula is:

Each gram of Hydrocortisone Cream USP 1% provides 10 mg of hydrocortisone in a non-staining water washable cream base consisting of stearyl alcohol, glyceryl monostearate, polyoxyl 40 stearate, isopropyl palmitate, paraffin, sorbitan monostearate, glycerin, lactic acid, potassium sorbate and purified water.

Each gram of Hydrocortisone Ointment, USP 1% provides 10 mg of hydrocortisone in a white petrolatum base.

Topical corticosteroids share anti-inflammatory, anti-pruritic and vasoconstrictive actions.

The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.

The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.

Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment of resistant dermatoses (see DOSAGE AND ADMINISTRATION ). Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.

Topical corticosteroids are indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses.

Topical corticosteroids are contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation.

Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushing's syndrome, hyperglycemia and glycosuria in some patients.

Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings.

Therefore, patients receiving a large dose of a potent topical steroid applied to a large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute a less potent steroid.

Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids.

Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (see PRECAUTIONS — Pediatric Use ).

If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.

In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If a favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.

Patients using topical corticosteroids should receive the following information and instructions.

The following tests may be helpful in evaluating the HPA axis suppression. Urinary free cortisol test ACTH stimulation test

Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.

Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.

Corticosteroids are generally teratogenic in laboratory animals when administered systemically in relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.

It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman.

Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushing’s syndrome than mature patients because of larger skin surface area to body weight ratio.

Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushing's syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema.

Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.

The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae, miliaria.

Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (see PRECAUTIONS ).

Topical corticosteroids are generally applied to the affected area as a thin film from two to four times daily depending on the severity of the condition.

Occlusive dressings may be used for the management of psoriasis or recalcitrant conditions.

If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted.

Hydrocortisone Cream USP 1% 1 oz (28.4 g) tube Hydrocortisone Ointment USP 1% 1 oz (28.4 g) tube

Manufactured by: Actavis Mid Atlantic LLC 1877 Kawai Road Lincolnton, NC 28092 USA

FORM NO. 0321/1326        Rev.10/14  VC4497

NDC 64980-302-30

Rising

Procto-Pack 1%

Hydrocortisone Cream USP, 1%

NOTE PHARMACIST:

See Patient Instructions on reverse side.

Store at room temperature. Avoid Freezing.

Rx Only

Rising Pharmaceuticals, Inc. Allendale, NJ 07401

Manufacturer

Rising Pharmaceuticals, Inc.

Active Ingredients

Source

Drugs and Medications [0 Results]

None

Clinical Trials [3 Associated Clinical Trials listed on BioPortfolio]

A New Class IIb MD in Proctological Disorders

The aim of this study is primarily to investigate the performance of a new medical device not yet CE marked in comparison with placebo, in relieving proctological symptomatology in adult p...

Probiotic Treatment of Ulcerative Colitis With Trichuris Suis Ova (TSO)

The PROCTO trial is a double-blind randomized, placebo-controlled, 24-week, comparative, exploratory phase II proof of concept trial. The trial will be conducted with 2 treatment groups as...

Diagnostic Outcomes of Patients Presenting With Per Rectal Bleed in Surgical Departments of Services Hospital Lahore

It is a cross sectional study in which investigators will be recruiting patients of any sex above 12 years of age who will present to surgical outdoor with per rectal bleed. Investigators ...

PubMed Articles [0 Results]

None

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topic

Immunoassay - ELISA
Immunoassays are quick and accurate tests to detect specific molecules. Immunoassays rely on an antibody to bind to the specific structure of a molecule. Antibodies are proteins generated by animals in response to the invasion of a foreign molecule (anti...


Drugs and Medication Quicklinks


Searches Linking to this Drug Record