Advertisement

Topics

Parenchymal Blood Volume Assessed by C-Arm-Based Computed Tomography in Immediate Posttreatment Evaluation of Drug-Eluting Bead Transarterial Chemoembolization in Hepatocellular Carcinoma.

08:00 EDT 20th October 2015 | BioPortfolio

Summary of "Parenchymal Blood Volume Assessed by C-Arm-Based Computed Tomography in Immediate Posttreatment Evaluation of Drug-Eluting Bead Transarterial Chemoembolization in Hepatocellular Carcinoma."

The aim of this study was to assess clinical utility of the quantitative perfusion parameter called parenchymal blood volume (PBV), as derived from C-arm-based computed tomography (CT), for immediate posttreatment assessment of drug-eluting bead (DEB) transarterial chemoembolization (TACE) in hepatocellular carcinoma (HCC).

Affiliation

Journal Details

This article was published in the following journal.

Name: Investigative radiology
ISSN: 1536-0210
Pages:

Links

DeepDyve research library

PubMed Articles [28260 Associated PubMed Articles listed on BioPortfolio]

Computed Tomography-Assessed Sarcopenia Indexes Predict Major Complications following Surgery for Hepatopancreatobiliary Malignancy: A Meta-Analysis.

Computed tomography (CT)-assessed sarcopenia indexes have been reported to predict postoperative morbidity and mortality; however conclusions drawn from different indexes and studies remain controvers...

Selecting Patients for Lobar Lung Volume Reduction Therapy: What Quantitative Computed Tomography Parameters Matter?

 Evaluation of emphysema distribution with quantitative computed tomography (qCT) prior to endoscopic lung volume reduction (ELVR) is recommended. The aim of this study was to determine which of the...

Evidence of association of circulating epigenetic-sensitive biomarkers with suspected coronary heart disease evaluated by Cardiac Computed Tomography.

Circulating biomarkers available in clinical practice do not allow to stratify patients with coronary heart disease (CHD) prior the onset of a clinically relevant event. We evaluated the methylation s...

Comparison of Accuracy of Left Atrial Area and Volume by Two-dimensional Trans-thoracic Echocardiography Versus Computed Tomography.

Left atrial (LA) size is prognostic of cardiovascular events and can be quantified as diameter, area, or volume. While LA area measurement by 2-dimensional (2D) echocardiography is performed by tracin...

Navigating the Pulmonary Perfusion Map: Dual-Energy Computed Tomography in Acute Pulmonary Embolism.

Pulmonary embolism is the third most common acute cardiovascular disease. Dual-energy computed tomography perfusion imaging is a promising adjunct in the detection of acute PE providing simultaneous f...

Clinical Trials [14320 Associated Clinical Trials listed on BioPortfolio]

VOLtage-based Contrast Media AdaptatioN in Coronary Computed Tomography Angiography

The purpose of this study is to prospectively evaluate the effectiveness of low-volume contrast media (CM) injection protocols adapted to tube voltage in patients undergoing Coronary Compu...

Performance of the Water-Enema Computed Tomography (WE-CT)

The WE-CT is an innovative and easy practice imaging technique of colon tumors; it is based on the colon distension by a high volume of warm water and a multidetector CT acquisition after ...

Estimation of Standard Liver Volume in the Indian Population

Estimation of liver volume is important for live donor liver transplant as well as extended liver resections. Computed tomography (CT) volumetry which is currently a gold standard for live...

Cone Beam Computed Tomography for Breast Imaging

The primary aim of this study is to investigate the use of cone beam computed tomography (CBCT) for breast imaging in the diagnostic setting by providing a compelling body of evidence inco...

Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography

The purpose of this study is to evaluate the diagnostic accuracy of multi-detector computed tomography using 320 detectors for identifying the combination of coronary artery stenosis ≥ 5...

Medical and Biotech [MESH] Definitions

An imaging technique using a device which combines TOMOGRAPHY, EMISSION-COMPUTED, SINGLE-PHOTON and TOMOGRAPHY, X-RAY COMPUTED in the same session.

Computed tomography where there is continuous X-ray exposure to the patient while being transported in a spiral or helical pattern through the beam of irradiation. This provides improved three-dimensional contrast and spatial resolution compared to conventional computed tomography, where data is obtained and computed from individual sequential exposures.

Computed tomography modalities which use a cone or pyramid-shaped beam of radiation.

Tomography using x-ray transmission and a computer algorithm to reconstruct the image.

Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Relevant Topics

Drug Discovery
Clinical Approvals Clinical Trials Drug Approvals Drug Delivery Drug Discovery Generics Drugs Prescription Drugs In the fields of medicine, biotechnology and pharmacology, drug discovery is the process by which drugs are dis...

Pharmacy
Pharmacy is the science and technique of preparing as well as dispensing drugs and medicines. It is a health profession that links health sciences with chemical sciences and aims to ensure the safe and effective use of pharmaceutical drugs. The scope of...


Searches Linking to this Article