Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus.

07:00 EST 9th March 2018 | BioPortfolio

Summary of "Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus."

Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions and used two Medtronic Paradigm Enlite-2 sensors under closed-loop therapy. CGM readings were compared with plasma glucose during different periods: one hour before exercise, during exercise, and four hours after the end of exercise. In aerobic sessions, the median absolute relative difference (MARD) increased from 9.5% before the beginning of exercise to 16.5% during exercise (< 0.001), and then decreased to 9.3% in the first hour after the end of exercise (< 0.001). For the anaerobic sessions, the MARD before exercise was 15.5% and increased without statistical significance to 16.8% during exercise realisation (= 0.993), and then decreased to 12.7% in the first hour after the cessation of anaerobic activities (= 0.095). Results indicate that CGM might present lower accuracy during aerobic exercise, but return to regular operation a few hours after exercise cessation. No significant impact for anaerobic exercise was found.

Affiliation

Journal Details

This article was published in the following journal.

Name: Biosensors
ISSN: 2079-6374
Pages:

Links

DeepDyve research library

PubMed Articles [12231 Associated PubMed Articles listed on BioPortfolio]

Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer l...

Glucose Sensing in the Subcutaneous Tissue: Attempting to Correlate the Immune Response with Continuous Glucose Monitoring Accuracy.

Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes.

This study evaluated the safety and performance of the Guardian™ continuous glucose monitoring (CGM) system in children and adolescents with type 1 diabetes (T1D).

A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.

Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D).

Prediction Quality of Glucose Trend Indicators in Two Continuous Tissue Glucose Monitoring Systems.

Continuous interstitial glucose monitoring (CGM) systems often provide glucose trend indicators (e.g., arrows) in addition to current glucose values. These indicators are recommended to be used in the...

Clinical Trials [7467 Associated Clinical Trials listed on BioPortfolio]

Accuracy, Feasibility and Acceptance of CGM Lupus

This is a prospective monocenter, non-randomised, open-lable single-group intervention diagnostic trial on the accuracy, reliability and feasibility of the continuous glucose monitoring sy...

Assessment of the Accuracy,Feasibility,Safety of Continuous Glucose Monitoring System

Real-time continuous glucose monitoring system (CGMS) has been attempted to be used in ICU, but its feasibility, accuracy and confounding factors are controversial.

Accuracy and Safety of Real Time Continuous Glucose Monitoring Before, During and After Surgery

The purpose of this study is to determine the safety and accuracy of the Real-Time Continuous Glucose monitoring System (RT-CGMS)in measuring glucose in patients scheduled for surgery; bef...

Assessment of Glucose Concentrations in People Without Diabetes Mellitus After Standardized Meals and in Daily Life

Participants will perform blood glucose monitoring (BGM) over the course of 14 days and, in parallel, wear continuous glucose monitoring (CGM) systems. Because current CGM systems typicall...

Evaluation of the Accuracy of an Implanted Glucose Sensor

The purpose of this clinical investigation is to evaluate the accuracy of the Senseonics Continuous Glucose Monitoring System (Senseonics CGM System) measurements when compared with refere...

Medical and Biotech [MESH] Definitions

The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine.

Self evaluation of whole blood glucose levels outside the clinical laboratory. A digital or battery-operated reflectance meter may be used. It has wide application in controlling unstable insulin-dependent diabetes.

Simultaneous and continuous monitoring of several parameters during sleep to study normal and abnormal sleep. The study includes monitoring of brain waves, to assess sleep stages, and other physiological variables such as breathing, eye movements, and blood oxygen levels which exhibit a disrupted pattern with sleep disturbances.

Hospital unit providing continuous monitoring of the patient following anesthesia.

Maintenance of a constant blood glucose level by perfusion or infusion with glucose or insulin. It is used for the study of metabolic rates (e.g., in glucose, lipid, amino acid metabolism) at constant glucose concentration.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Relevant Topics

Diabetes
Diabetes is a lifelong condition that causes a person's blood sugar level to become too high. The two main types of diabetes are: type 1 diabetes type 2 diabetes In the UK, diabetes affects approximately 2.9 million people. There are a...

Nephrology - kidney function
Nephrology is a specialty of medicine and pediatrics that concerns itself with the study of normal kidney function, kidney problems, the treatment of kidney problems and renal replacement therapy (dialysis and kidney transplantation). Systemic conditions...


Searches Linking to this Article