Summary of "Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents."

Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is crucial for the sensitivity of the CWA.

Affiliation

Journal Details

This article was published in the following journal.

Name: International journal of laboratory hematology
ISSN: 1751-553X
Pages:

Links

DeepDyve research library

PubMed Articles [20787 Associated PubMed Articles listed on BioPortfolio]

Clot waveform analysis in Clauss fibrinogen assay contributes to classification of fibrinogen disorders.

Clauss fibrinogen assay (CFA) is widely used as a screening test to detect fibrinogen disorders. However, CFA alone cannot distinguish quantitative and qualitative defects because it depends on functi...

Research and analysis of cadmium residue in tomato leaves based on WT-LSSVR and Vis-NIR hyperspectral imaging.

The reliability and validity of Vis-NIR hyperspectral imaging were investigated for the determination of heavy metal content in tomato leaves under different cadmium stress. Besides, a method involvin...

Determination of toxic metals in leather by wavelength dispersive X-ray fluorescence (WDXRF) and inductively coupled plasma optical emission spectrometry (ICP OES) with emphasis on chromium.

The tanning industry is one of the largest environmental polluters due to high generation waste in all production processes, but the tanning is particularly worrisome due to the use of significant amo...

Significant reduction in umbilical artery metabolic acidosis after implementation of intrapartum ST waveform analysis of the fetal electrocardiogram.

Although the evidence regarding the benefit of using ST waveform analysis of the fetal electrocardiogram is conflicting, ST waveform analysis is considered as adjunct to identify fetuses at risk for a...

Characterization of strut indentation during mechanical thrombectomy in acute ischemic stroke clot analogs.

Although it is common practice to wait for an 'embedding time' during mechanical thrombectomy (MT) to allow strut integration of a stentriever device into an occluding thromboembolic clot, there is a ...

Clinical Trials [5504 Associated Clinical Trials listed on BioPortfolio]

Waveform Analysis In Snakebite Victims With Hematotoxicity

In hematotoxic snakebites, due to the lack of a better alternative, 20 minute whole blood clotting test (20'WBCT) or Clotting time remains the standard test in developing countries even th...

Epidural Waveform Analysis for Thoracic Epidural Blocks

Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss-of-resistance (LOR): when the needle/catheter tip is correctly positioned inside the epidural space, pressu...

Performance of Long-wavelength Autofluorescence Imaging

Fundus autofluorescence imaging has become an important diagnostic tool in ophthalmology, guiding diagnosis and assessment of progression of retinal diseases. This study investigates the p...

Comparison of the Efficacy of Phototherapy Using Blue LED's With Wavelength 478 vs. 459 nm.

Treatment of neonatal jaundice is phototherapy with blue light at wavelength about 460 nm and irradiance > 30 uw/cm2/nm. Though, recent in vitro models have suggested that a wavelength of ...

A Comparison Between Conventional and Waveform-Confirmed Loss-of-Resistance for Thoracic Epidural Blocks

In the investigators' institution, the failure rate for thoracic epidural blocks is 23.1%. This stems from the prevalence of trainee operators coupled with the non-specific nature of loss-...

Medical and Biotech [MESH] Definitions

The measurement of the amplitude of the components of a complex waveform throughout the frequency range of the waveform. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed)

Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source.

A multistage process that includes the determination of a sequence (protein, carbohydrate, etc.), its fragmentation and analysis, and the interpretation of the resulting sequence information.

Gastric analysis for determination of free acid or total acid.

The identification, analysis, and resolution of moral problems that arise in the care of patients. (Bioethics Thesaurus)

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Searches Linking to this Article