Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET.

08:00 EDT 12th April 2019 | BioPortfolio

Summary of "Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET."

The scintillator bismuth germanate (BGO) has attractive properties for positron emission tomography (PET) systems such as high stopping power, high photo-fraction, and relatively low cost. However, its moderate scintillation light yield and slow rise and decay time compared to lutetium (yttrium) oxyorthosilicate (L(Y)SO) results in a degradation of coincidence timing resolution when scintillation photons are used for timing. Recently, it has been reported that the coincidence timing resolution of BGO can be improved by detecting Cerenkov photons, while scintillation photons still provide energy information. However, the measured coincidence timing spectrum showed much longer tails compared to the single Gaussian distribution. Because of this, TOF PET detectors based on BGO will perform worse than the full width at half maximum (FWHM) of the distribution, which is the most common metric for timing resolution, would suggest. From simulation studies, during the first few picoseconds, BGO generates ~16 Cerenkov photons per photoelectric interaction, following a 511 keV gamma ray interaction, while the probability of producing a scintillation photon during the first few picoseconds is very small. Therefore, when we configure a BGO crystal with dual-ended readout, the first arriving photons among the two opposing SiPMs are most likely Cerenkov photons, and by selecting the appropriate SiPM, an improvement in coincidence timing resolution can be achieved. In this study, both ends of a 3 × 3 × 20 mm<sup>3</sup> BGO crystal were coupled to NUV-HD SiPMs. Trigger time differences from the dual-ended readout of BGO were widely distributed due to detecting a mixture of prompt Cerenkov and scintillation photons on both SiPMs. When using trigger times from only a single SiPM, the estimated coincidence timing resolution between two identical BGO detectors was 463 ps FWHM and 1463 ps FWTM. In contrast, when using trigger times from both SiPMs, the estimated coincidence timing resolution was 399 ps FWHM and 936 ps FWTM with no loss of events. Based on a recent report, high-bandwidth amplifiers were implemented and shown to further improve the estimated coincidence timing resolution to 331 ps FWHM and 923 ps FWTM. In summary, the coincidence timing resolution of BGO, most notably the FWTM, was significantly improved using time information from the dual-ended readout.

Affiliation

Journal Details

This article was published in the following journal.

Name: Physics in medicine and biology
ISSN: 1361-6560
Pages:

Links

DeepDyve research library

PubMed Articles [11374 Associated PubMed Articles listed on BioPortfolio]

Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs.

Detectors with depth encoding capability, good energy resolution and good timing resolution are required to develop high performance whole body and total body PET scanners. In this work, an 8×8 LYSO ...

High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET.

Scintillator based radiation detectors readout by SiPMs successively break records in their reached time resolution. Nevertheless, new challenges in time of flight positron emission tomography (TOF-PE...

Eradication Efficacy of Modified Dual Therapy Compared with Bismuth-Containing Quadruple Therapy as a First-Line Treatment of Helicobacter pylori.

This study assessed the effectiveness, adverse events, patient adherence, and costs of modified dual therapy compared with bismuth-containing quadruple therapy for treating Helicobacter pylori infecti...

Towards a second-generation PET/MR insert with enhanced timing and count rate performance.

Previously we have developed a first-generation PET insert prototype for small animal PET/MR imaging, which used resistor-based charge division multiplexing circuits and SensL B-series silicon photomu...

Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept.

Achieving fast timing in positron emission tomography (PET) at the level of few tenth of picoseconds is limited by the photon emission rate of existent materials with standard scintillation mechanisms...

Clinical Trials [3657 Associated Clinical Trials listed on BioPortfolio]

High Dose of Dual Therapy Plus Bismuth for Helicobacter Pylori Treatment

Dual therapy for Helicobacter Pylori including a proton pump inhibitor (PPI) and amoxicillin. Amoxicillin has low resistance rate as well as low percentage of side effects. No trial has ex...

Comparing the Efficacy of Hybrid, High-dose Dual and Bismuth Quadruple Therapies

Both hybrid and high-dose dual therapies developed by the scholars from Taiwan can achieve a high eradication rate for clarithromycin-resistant strains, and have a great potential to repla...

Efficacies of HDDT With or Without Bismuth vs Amoxicillin-metronidazole BQT for First-line H Pylori Eradication

Up to know, three is few large-scale, randomized study prospectively and simultaneously comparing the efficacy, adverse effects and patient compliance of high-dose dual therapy (HDDT) with...

Efficacy of High-dose Dual Therapy vs Bismuth-containing Quadruple Therapy for Rescue Treatment of Hp Infection

Up to now, there is few randomized, large scale study prospectively and simultaneously comparing the efficacy, adverse effects and patient adherence of high-dose dual therapy (HDDT) and bi...

Efficacy of High-dose Dual Therapy vs Bismuth-containing Quadruple Therapy for First-line Treatment of Hp Infection

Up to now, there is few randomized, large scale study prospectively and simultaneously comparing the efficacy, adverse effects and patient adherence of high-dose dual therapy (HDDT) and bi...

Medical and Biotech [MESH] Definitions

Using certified ELECTRONIC HEALTH RECORDS technology to improve quality, safety, efficiency, and reduce HEALTHCARE DISPARITIES; engage patients and families in their health care; improve care coordination; improve population and public health; while maintaining privacy and security.

A dual specificity phosphatase subtype that plays a role in intracellular signal transduction by inactivating MITOGEN-ACTIVATED PROTEIN KINASES. It has specificity for EXTRACELLULAR SIGNAL-REGULATED MAP KINASES.

A dual specificity phosphatase subtype that plays a role in intracellular signal transduction by inactivating MITOGEN-ACTIVATED PROTEIN KINASES. It has specificity for EXTRACELLULAR SIGNAL-REGULATED MAP KINASES and is primarily localized to the CYTOSOL.

A dual specificity phosphatase subtype that plays a role in intracellular signal transduction by inactivating MITOGEN-ACTIVATED PROTEIN KINASES. It has specificity for EXTRACELLULAR SIGNAL-REGULATED MAP KINASES and is primarily localized to the CELL NUCLEUS.

A metallic element that has the atomic symbol Bi, atomic number 83 and atomic weight 208.98.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Searches Linking to this Article