Advertisement

Topics

Electric field driven multi-state magnetization switching in triangular nanomagnets on piezoelectric substrate.

08:00 EDT 12th April 2019 | BioPortfolio

Summary of "Electric field driven multi-state magnetization switching in triangular nanomagnets on piezoelectric substrate."

Electric field control of magnetic state switching mediated by magneto-elastic coupling in multiferroic heterostructures consisting of shape anisotropic magnetostrictive nanomagnets elastically coupled with a piezoelectric substrate has a promising potential for next generation magneto-elastic memory and logic devices. In this work, by using micromagnetic simulation, we showed that localized strain-induced magnetic anisotropy caused by the electric field-induced piezostrain combined with strong multifold shape anisotropy effect can be used for achieving a multistate switching of magnetization in a triangular soft magnetic nano-island on a piezoelectric substrate. A piezostrain-induced uniaxial magnetic anisotropy pulse applied in specific directions switches the magnetization within the triangular nanomagnet by an angle of 60<sup>0</sup> from the initial state. The relation between critical magnitude of the strain pulse for the switching of the magnetization states and geometric parameters (thickness and lateral size) within the triangular nanomagnets has been worked out. Complete cycles of clockwise as well as counter-clockwise switching of the magnetization states of the triangular nanomagnet have been achieved by a series of sequential switching with different directions of applied strain-induced magnetic anisotropy. This local gating scheme-based multistate switching can be used for electric field-induced ultra-fast, deterministic and reversible magnetization switching which are the key challenges in designing of the magnetoelastic and/or magnetoelectric memory and logic devices.

Affiliation

Journal Details

This article was published in the following journal.

Name: Journal of physics. Condensed matter : an Institute of Physics journal
ISSN: 1361-648X
Pages:

Links

DeepDyve research library

PubMed Articles [16950 Associated PubMed Articles listed on BioPortfolio]

TbO in a calcium apatite matrix featuring a triple trigger-type relaxation of magnetization.

Tb for Ca substituted hydroxyapatite ceramic samples with composition Ca10-xTbx(PO4)6(OH1-x/2-δ)2, where x = 0.1, 0.5, were synthesized by solid-state reaction at 1300 °C in air, and their crystal s...

Electric Field Controlled Magnetization in GaAs/AlGaAs Heterostructures-chiral Organic Molecules Hybrids.

We study GaAs/AlGaAs devices hosting a two-dimensional electron gas and coated with a monolayer of chiral organic molecules. We observe clear signatures of room temperature magnetism, which is induced...

Influence of edge magnetization and electric fields on zigzag silicene, germanene and stanene nanoribbons.

Using a multi-orbital tight-binding model, we have studied the edge states of zigzag silicene, germanene, and stanene nanoribbons (ZSiNRs, ZGeNRs and ZSnNRs, respectively) in the presence of the Coulo...

Magnetization reversal driven by low dimensional chaos in a nanoscale ferromagnet.

Energy-efficient switching of magnetization is a central problem in nonvolatile magnetic storage and magnetic neuromorphic computing. In the past two decades, several efficient methods of magnetic swi...

All-optical generation of magnetization with arbitrary three-dimensional orientations.

In this Letter, all-optical generation of magnetization with arbitrary three-dimensional (3D) orientations is numerically demonstrated through the inverse Faraday effect (IFE) by using a reversing cal...

Clinical Trials [6432 Associated Clinical Trials listed on BioPortfolio]

Bioelectric Field Imaging Near Human Skin Wounds

The investigators have developed a new non-invasive medical device called the Bioelectric Field Imager. They plan to use this device to measure the electric field near small lancet wounds ...

A Clinical Trial of Dermacorder for Detecting Malignant Skin Lesions

The Dermacorder measures the electric field in the skin. Malignant skin lesions disrupt the skin's normal electric field and this abnormal electric field can be detected by the Dermacorder...

Optune Device - TT Field Plus Nivolumab and Ipilimumab for Melanoma With Brain Metastasis

This phase II study will evaluate the safety of combining intermediate frequency electric field (TT Field) with immunotherapy in melanoma patients with brain metastasis. The data of this s...

Neuromuscular Re-eduaction, Exercise and Electric Dry Needling vs. Electric Dry Needling for Stress Urinary Incontinence

The purpose of this research is to compare two different approaches for treating patients with stress urinary incontinence: neuromuscular re-education, impairment-based exercise and electr...

Electric and Manual Toothbrushes in Nursing Homes

Effect of electric toothbrush on oral hygiene in nursing home residents tested I randomized clinical trial for 2 months and followed up 12 months after baseline

Medical and Biotech [MESH] Definitions

Devices for accelerating charged particles in a spiral path by a constant-frequency alternating electric field. This electric field is synchronized with the movement of the particles in a constant magnetic field.

Electrophoresis in which the direction of the electric field is changed periodically. This technique is similar to other electrophoretic methods normally used to separate double-stranded DNA molecules ranging in size up to tens of thousands of base-pairs. However, by alternating the electric field direction one is able to separate DNA molecules up to several million base-pairs in length.

Injuries caused by electric currents. The concept excludes electric burns (BURNS, ELECTRIC), but includes accidental electrocution and electric shock.

Fibrocartilage that makes up the triangular fibrocartilage complex which is found in the WRIST JOINT.

Gene rearrangement of the B-lymphocyte which results in a substitution in the type of heavy-chain constant region that is expressed. This allows the effector response to change while the antigen binding specificity (variable region) remains the same. The majority of class switching occurs by a DNA recombination event but it also can take place at the level of RNA processing.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Searches Linking to this Article