Summary of "Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors."

Parallax error caused by the detector crystal thickness degrades spatial resolution at the peripheral regions of the field-of-view (FOV) of a scanner. To resolve this issue, depth-of-interaction (DOI) measurement is a promising solution to improve the spatial resolution and its uniformity over the entire FOV. Even though DOI detectors have been used in dedicated systems with a small ring diameter such as for human brain, breast and small animals, the use of DOI detectors for a large bore whole-body PET system has not been demonstrated yet. We have developed a 4-layered DOI detector, and its potential for a brain dedicated system has been proven in our previous development. In the present work, we investigated the use of the 4-layer DOI detector for a large bore PET system by developing the world's first whole-body prototype. We evaluated its performance characteristics in accordance with the NEMA NU 2 standard. Furthermore, the impact of incorporating DOI information was evaluated with the NEMA NU 4 image quality phantom. Point source images were reconstructed with a filtered back projection (FBP), and an average spatial resolution of 5.2±0.7 mm was obtained. For the FBP image, the 4-layer DOI information improved the radial spatial resolution by 48% at the 20 cm offset position. The peak noise-equivalent count rate (NECR) was 22.9 kcps at 7.4 kBq/mL and the scatter fraction was 44%. The system sensitivity was 5.9 kcps/MBq. For the NEMA NU 2 image quality phantom, the 10-mm-sphere was clearly visualized without any artifacts. For the NEMA NU 4 image quality phantom, we measured the phantom at 0, 10 and 20 cm offset positions. As a result, we found the image with 4-layer DOI could visualize the 2-mm-diameter hot cylinder although it could not be recognized on the image without DOI. The average improvements in the recovery coefficients for the five hot rods (1-5 mm) were 0.3%, 4.4% and 26.3% at the 0, 10 and 20 cm offset positions, respectively (except for the 1-mm-diameter rod at the 20 cm offset position). Although several practical issues (such as adding end-shields) remain to be addressed before the scanner is ready for clinical use, we showed that the 4-layer DOI technology provided higher and more uniform spatial resolution over the FOV and improved contrast for small uptake regions located at the peripheral FOV, which could improve detectability of small and distal lesions such as nodal metastases, especially in obese patients.

Affiliation

Journal Details

This article was published in the following journal.

Name: Physics in medicine and biology
ISSN: 1361-6560
Pages:

Links

DeepDyve research library

PubMed Articles [16836 Associated PubMed Articles listed on BioPortfolio]

Mini EXPLORER II: a prototype high-sensitivity PET/CT scanner for companion animal whole body and human brain scanning.

As part of the EXPLORER total-body positron emission tomography (PET) project, we have designed and built a high-resolution, high-sensitivity PET/CT scanner which is expected to have excellent perform...

Performance of a dual-layer scanner for hybrid SPECT/CBCT.

Purpose Fluoroscopic procedures involving radionuclides would benefit from interventional nuclear imaging by obtaining real-time feedback on the activity distribution. We have previously proposed...

NEMA NU-4 performance evaluation of a non-human primate animal PET.

The Eplus-260 primate PET is an animal PET imaging system developed by the Institute of High Energy Physics, Chinese Academy of Sciences, which is designed to image non-human primates, especially the ...

First prototyping of a dedicated PET system with the hemisphere detector arrangement.

A strong demand is expected for high-sensitivity, high-resolution, and low-cost brain positron emission tomography (PET) imaging for early diagnosis of dementia as well as for general neuroscience stu...

Measurement of S100B protein: evaluation of a new prototype on a bioMérieux Vidas® 3 analyzer.

Background The addition of S100B protein to guidelines for the management of mild traumatic brain injury (mTBI) decreases the amount of unnecessary computed tomography (CT) scans with a significant de...

Clinical Trials [7965 Associated Clinical Trials listed on BioPortfolio]

Evaluation of Breast CT

The purpose of this study is to evaluate the efficacy of breast computed tomography (CT) for breast cancer detection. Initially, up to 20 female volunteers who will likely have normal bre...

Assessment of Scan Quality of Sparse OCT Retina Scanner (MimoStudy01)

Optical Coherence Tomography (OCT) is an established non-invasive medical imaging technique ophthalmologists use to diagnose and monitor retinal diseases such as age-related macular degene...

Prospective Evaluation of an RDT to Screen for Gambiense HAT and Diagnose P. Falciparum Malaria

A prototype rapid diagnostic test (RDT) to simultaneously screen for gambiense human African trypanosomiasis (HAT) and diagnose P. falciparum malaria (the "HAT/malaria combo") has recently...

Testing Self-regulation Effects of a `Smart Toy'

The present experimental study aims to explore the effect of an interactive smart toy on children's stress modulation during a stressful experience compared to a non-interactive prototype....

A Pharmacokinetic (PK) Study of ACH-0144471 Modified Release Prototype Formulations in Healthy Subjects

The purpose of this study is to evaluate and compare the plasma PK profiles of study drug, ACH-0144471, in healthy subjects after administration of a single dose of multiple ACH-0144471 pr...

Medical and Biotech [MESH] Definitions

Educational programs structured in such a manner that the participating professionals, physicians, or students develop an increased awareness of their performance, usually on the basis of self-evaluation questionnaires.

An imaging technique that combines a POSITRON-EMISSION TOMOGRAPHY (PET) scanner and a CT X RAY scanner. This establishes a precise anatomic localization in the same session.

An organized procedure carried out by a select committee of professionals in evaluating the performance of other professionals in meeting the standards of their specialty. Review by peers is used by editors in the evaluation of articles and other papers submitted for publication. Peer review is used also in the evaluation of grant applications. It is applied also in evaluating the quality of health care provided to patients.

A ubiquitous target SNARE protein that interacts with SYNTAXIN and SYNAPTOBREVIN. It is a core component of the machinery for intracellular MEMBRANE FUSION. The sequence contains 2 SNARE domains, one is the prototype for the Qb-SNARES, and the other is the prototype for the Qc-SNARES.

The physical characteristics of the body, including the mode of performance of functions, the activity of metabolic processes, the manner and degree of reactions to stimuli, and power of resistance to the attack of pathogenic organisms.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Relevant Topics

Breast Cancer
Track and monitor developments in breast cancer research and commercial development.  Follow the tabs above to read the latest global news, research, clinical trials on breast cancer and follow companies active in the development of breast cancer tr...

Obesity
Obesity is the condition in which excess fat has accumulated in the body (mostly in subcutaneous tissues). clinical obesity is considered to be present when a person has a BMI of over 30 (Oxford Dictionary of Medicine). It is becoming increasing common i...


Searches Linking to this Article