Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes.

08:00 EDT 6th May 2019 | BioPortfolio

Summary of "Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes."

Real-time continuous glucose monitoring (CGM) devices help detect glycemic excursions associated with exercise, meals, and insulin dosing in patients with type 1 diabetes (T1D). However, the delay between interstitial and blood glucose may result in CGM underestimating the true change in glycemia during activity. The purpose of this study was to examine CGM discrepancies during exercise and the meal postexercise versus self-monitoring of blood glucose (SMBG). Seventeen adults with T1D using insulin pump therapy and CGM completed 60 min of aerobic exercise on three occasions. A standardized meal was given 30 min postexercise. SMBG was measured during exercise and in recovery using OmniPod Personal Diabetes Manager (PDM; Insulet, Billerica, MA) with built-in glucose meter (FreeStyle; Abbott Laboratories, Abbott Park, IL), while CGM was measured with Dexcom G4 with 505 algorithm ( = 4) or G5 ( = 13), which were calibrated with subjects' own PDM. SMBG showed a large drop in glycemia during exercise, while CGM showed a lag of 12 ± 11 (mean ± standard deviation) minutes and bias of -7 ± 19 mg/dL/min during activity. Mean absolute relative difference (MARD) for CGM versus SMBG was 13 (6-22)% [median (interquartile range)] during exercise and 8 (5-14)% during mealtime. Clarke error grids showed CGM values were in zones A and B 94%-99% of the time for SMBG. In summary, the drop in CGM lags behind the drop in blood glucose during prolonged aerobic exercise by 12 ± 11 min, and MARD increases to 13 (6-22)% during exercise as well. Therefore, if hypoglycemia is suspected during exercise, individuals should confirm glucose levels with a capillary glucose measurement.

Affiliation

Journal Details

This article was published in the following journal.

Name: Diabetes technology & therapeutics
ISSN: 1557-8593
Pages:

Links

DeepDyve research library

PubMed Articles [31248 Associated PubMed Articles listed on BioPortfolio]

Reliability of real-time continuous glucose monitoring in infants.

Neonatal hypoglycemia is a common and treatable risk factor for neurological impairment. Real-time continuous glucose monitoring (RT-CGM) can show glucose concentrations in real time. Using an alarm o...

Real-Time Continuous Glucose Monitoring in Gestational Diabetes: A Randomized Controlled Trial.

 To evaluate whether real-time continuous glucose monitoring improves glycemic control over intermittent self-monitoring of blood glucose in gestational diabetes.

Modelling potential cost savings from use of real-time continuous glucose monitoring in pregnant women with Type 1 diabetes.

To investigate potential cost savings associated with the use of real-time continuous glucose monitoring (RT-CGM) throughout pregnancy in women with type 1 diabetes.

Comparison of flash glucose monitoring with real time continuous glucose monitoring in children and adolescents with type 1 diabetes treated with continuous subcutaneous insulin infusion.

In 2016 intermittently scanned continuous glucose monitoring (isCGM) became the first reimbursed CGM system in Belgium. Many children with type 1 diabetes (T1D) treated with multiple daily injections ...

Comments on García-Lorenzo et al. Cost-effectiveness analysis of real-time continuous monitoring glucose compared to self-monitoring of blood glucose for diabetes mellitus in Spain.

Clinical Trials [19599 Associated Clinical Trials listed on BioPortfolio]

Use of Real-Time Continuous Glucose Monitoring System in Patients With Type 1 Diabetes Mellitus

The purpose of this study is to determine whether a real-time continuous glucose monitoring system is able to improve HbA1c in patients suffering from type 1 diabetes compared to conventio...

Accuracy and Safety of Real Time Continuous Glucose Monitoring Before, During and After Surgery

The purpose of this study is to determine the safety and accuracy of the Real-Time Continuous Glucose monitoring System (RT-CGMS)in measuring glucose in patients scheduled for surgery; bef...

Comparison of Real-tiMe ContInuous gLucosE moNitoriNg With Self-monitorIng of Blood Glucose in Young AduLts With Type 1 diabeteS

The main objective of this study is to determine whether real-time continuous glucose monitoring (CGM) for 8 weeks is more efficacious compared to self-monitoring of blood glucose (SMBG) i...

Real-Time Continuous Glucose Monitoring (RT-CGM) in Patients With Type 1 Diabetes at High Risk for Low Glucose Values Using Multiple Daily Injections (MDI) in Germany (HYPODE-STUDY)

Demonstrate that usage of RT-CGM (Real time continuous glucose monitoring) reduces the frequency of low CGM-recorded glucose events in patients using MDI (Multiple daily injections) that a...

Assessment of the Accuracy,Feasibility,Safety of Continuous Glucose Monitoring System

Real-time continuous glucose monitoring system (CGMS) has been attempted to be used in ICU, but its feasibility, accuracy and confounding factors are controversial.

Medical and Biotech [MESH] Definitions

Ultrasonography applying the Doppler effect combined with real-time imaging. The real-time image is created by rapid movement of the ultrasound beam. A powerful advantage of this technique is the ability to estimate the velocity of flow from the Doppler shift frequency.

The ability to estimate periods of time lapsed or duration of time.

Recording serial images of a process at regular intervals spaced out over a longer period of time than the time in which the recordings will be played back.

A study that uses observations at multiple time points before and after an intervention (the "interruption"), in an attempt to detect whether the intervention has had an effect significantly greater than any underlying trend over time.

The continuous visual field seen by a subject through space and time.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Relevant Topic

Endocrine Disorders
Endocrine disorders are grouped into two categories: hormone imbalance - when a gland produces too much or too little of an endocrine hormone development of lesions (such as nodules or tumors) in the endocrine system, which may or may not affect...


Searches Linking to this Article