The cycle length criteria for His-bundle capture are capable of determining pacing types misclassified by the output criteria.

08:00 EDT 13th May 2019 | BioPortfolio

Summary of "The cycle length criteria for His-bundle capture are capable of determining pacing types misclassified by the output criteria."

His-bundle pacing is currently defined according to the output criteria. However, potential non-selective His bundle pacing (NSHBP) might be misclassified as right ventricular pacing by the output criteria.

Affiliation

Journal Details

This article was published in the following journal.

Name: Heart rhythm
ISSN: 1556-3871
Pages:

Links

DeepDyve research library

PubMed Articles [13366 Associated PubMed Articles listed on BioPortfolio]

Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy.

This study explores the feasibility of left bundle branch pacing (LBBP) and characterizes electrocardiogram (ECG) patterns during the pacing in comparison with conventional right ventricular pacing (R...

A Novel Pacing Maneuver to Verify the Post-Pacing Interval Minus the Tachycardia Cycle Length While Adjusting for Decremental Conduction: Using 'Dual Chamber Entrainment' for Improved Supraventricular Tachycardia Discrimination.

The post-pacing interval (PPI) minus the tachycardia cycle length (TCL) is frequently used to investigate tachycardias. However, a variety of issues (e.g. failure to entrain, decremental conduction, a...

Non-invasive electrocardiographic imaging of His-bundle and peri-left bundle pacing in left bundle branch block.

On-treatment comparison between corrective his bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of his-sync.

The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of an LV lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was...

Impact of Physiologic Pacing Versus Right Ventricular Pacing Among Patients With Left Ventricular Ejection Fraction Greater Than 35%: A Systematic Review for the 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay.

It is unclear whether physiologic pacing by either cardiac biventricular pacing (BiVP) or His-bundle pacing (HisBP) may prevent adverse structural and functional consequences known to occur among some...

Clinical Trials [6420 Associated Clinical Trials listed on BioPortfolio]

Imaging Study of Lead Implant for His Bundle Pacing

The purpose of this research study is to assess the implant success proportion of the Medtronic SelectSecure MRI SureScan Model 3830 pacing lead at the bundle of His for His bundle pacing.

His Bundle Pacing Registry

The His Bundle Pacing registry is a prospective, observational, multi-center registry performed to gain a broader understanding of 1) the His bundle pacing (HBP) device implant and follow-...

Mapping and Pacing of the His Bundle for Heart Failure Patients With Left Bundle Branch Block

This is a prospective, single-arm, non-randomized, non-blinded study designed to characterize the locations of His Bundle (HB) pacing that results in correction of electrical dyssynchrony ...

Comparison of His Bundle Pacing and Bi-Ventricular Pacing in Heart Failure With Atrial Fibrillation

This study is a multicenter, prospective, randomized cross-over study to compare His Bundle Pacing (HBP) with Bi-Ventricular Pacing (BiVP) in HF Patients with AF who need atrial-ventricula...

The His Optimised Pacing Evaluated for Heart Failure Trial (HOPE-HF).

This is a multi-centre, prospective randomised double-blinded cross over study, recruiting a sub-population of patients with heart failure. All patients will be implanted with a CRT (Card...

Medical and Biotech [MESH] Definitions

Moving oneself through space while confused or otherwise cognitively impaired. Patterns include akathisia, exhibiting neuroleptic-induced pacing and restlessness; exit seekers who are often newly admitted institution residents who try to open locked exit doors; self-stimulators who perform other activities such as turning doorknobs, in addition to continuous pacing; and modelers who shadow other pacers.

Small band of specialized CARDIAC MUSCLE fibers that originates in the ATRIOVENTRICULAR NODE and extends into the membranous part of the interventricular septum. The bundle of His, consisting of the left and the right bundle branches, conducts the electrical impulses to the HEART VENTRICLES in generation of MYOCARDIAL CONTRACTION.

Norms, criteria, standards, and other direct qualitative and quantitative measures used in determining the quality of health care.

Abnormal sleep-wake schedule or pattern associated with the CIRCADIAN RHYTHM which affect the length, timing, and/or rigidity of the sleep-wake cycle relative to the day-night cycle.

The state or condition of being a human individual accorded moral and/or legal rights. Criteria to be used to determine this status are subject to debate, and range from the requirement of simply being a human organism to such requirements as that the individual be self-aware and capable of rational thought and moral agency.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Searches Linking to this Article