Comparison of testing of collimator and beam alignment, focal spot size with slit camera, and tube current consistency using computed radiography and conventional screen-film systems.

08:00 EDT 16th May 2019 | BioPortfolio

Summary of "Comparison of testing of collimator and beam alignment, focal spot size with slit camera, and tube current consistency using computed radiography and conventional screen-film systems."

Conversion to a filmless technique of physical performance testing is becoming a topic of much interest to researchers. We assessed the use of a computed radiography (CR) system with postprocessing software as an alternative tool for performing the three physical performance tests of an x-ray tube. Collimator and beam alignment, focal spot size, and milliampere second (mAs) linearity, were performed using a CR system. Results were then compared with those obtained from a conventional screen-film (SF) system. The distances of collimator misalignment measured by the SF system were decreased while peak tube voltage (kVp) was increased (mAs was fixed), whereas those measured by CR were independent of exposure level. The degrees of beam collimator misalignment measured by the CR system were not different from those measured by the SF system. The differences in focal spot dimensions measured by SF and CR systems were less than 4% for large and small focal spot size in both width and length. The mAs linearity evaluated by the SF system agreed with those evaluated by the dose measurement at 50 kVp and 4 mAs, as well as 55 kVp and 3.2 mAs, while the mAs linearity test using the CR system agreed with those using the dose measurement method for all exposure levels. In summary, a CR system could be utilized to assess the three physical performance tests of a single x-ray tube, but required more time than an SF system. Medical physicists with image processing skills were needed to perform the analyses.

Affiliation

Journal Details

This article was published in the following journal.

Name: Journal of applied clinical medical physics
ISSN: 1526-9914
Pages:

Links

DeepDyve research library

PubMed Articles [12129 Associated PubMed Articles listed on BioPortfolio]

Impact of spot size variations on dose in scanned proton beam therapy.

In scanned proton beam therapy systematic deviations in spot size at iso-center can occur as a result of changes in the beam-line optics. There is currently no general guideline of the spot size accur...

Detection of the focal spot motion relative to the collimator axis of a linear accelerator under gantry rotation.

The potential for delivering high precision radiotherapy using linear accelerators (linacs) has been improved with the development of digital x-ray electronic portal imaging devices (EPID) for acquiri...

Improving resolution of head and neck CTA using the small x-ray tube focal spot.

CT-resolution depends on tube focal spot size. To investigate the effect of reducing focal spot on vessel wall clarity, 22 patients underwent head and neck CTA acquisition with large and small focal s...

OPTIMIZATION OF AN ADDITIONAL COLLIMATOR IN A BEAM DELIVERY SYSTEM FOR REDUCTION OF THE SECONDARY NEUTRON EXPOSURE IN PASSIVE CARBON-ION THERAPY.

The aim of this work is to optimize an additional collimator in a beam delivery system to reduce neutron exposure to patients in passive carbon-ion therapy. All studies were performed by Monte Carlo s...

Beam selection for stereotactic ablative radiotherapy using Cyberknife with multileaf collimation.

The Cyberknife system (Accuray Inc., Sunnyvale, CA) enables radiotherapy using stereotactic ablative body radiotherapy (SABR) with a large number of non-coplanar beam orientations. Recently, a multile...

Clinical Trials [7976 Associated Clinical Trials listed on BioPortfolio]

Comparison of Image Quality Between New Collimator LEHRS vs Siemens LEHR on Bone Scintigraphy

Comparison of quality image with a new LEHRS GE collimator vs standard LEHR Siemens collimator on bone scintigraphy.

EVALUATION OF THE EFFECT OF THE PERFECTA V-BEAM LASER ON ROSACEA

The purpose of this study is to further quantify the safety and effectiveness of the Syneron-Candela long pulse-duration, extended sub-pulse, larger spot-size prototype Perfecta V-Beam, 59...

SPOT Vision Screening

The purpose of this protocol is to determine if the Welch-Allyn Spot Vision Screener (SPOT) is effective at detecting various risk factors for poor vision in developmentally delayed childr...

Cardiac SPECT With Rotating Slant Hole Collimator

The goal is to conduct a clinical pilot study to evaluate the use of a rotating multi-segment slant-hole collimator in the detection of myocardial defects.

Matched Pair Study - Kinematic vs Mechanical Alignment

The aim of this study is to evaluate postoperative knee function after total knee arthroplasty performed according to the anatomical alignment and compare these results to those of a match...

Medical and Biotech [MESH] Definitions

Comparison of various psychological, sociological, or cultural factors in order to assess the similarities or diversities occurring in two or more different cultures or societies.

Techniques for using whole blood samples collected on filter paper for a variety of clinical laboratory tests.

The science and application of a double-beam transmission interference microscope in which the illuminating light beam is split into two paths. One beam passes through the specimen while the other beam reflects off a reference mirror before joining and interfering with the other. The observed optical path difference between the two beams can be measured and used to discriminate minute differences in thickness and refraction of non-stained transparent specimens, such as living cells in culture.

Detection of or testing for certain ALLELES, mutations, genotypes, or karyotypes that are associated with genetic traits, heritable diseases, or with a predisposition to a disease, or that may lead to the disease in descendants. It includes prenatal genetic testing.

Testing in which the source of the specimen or the person being tested is not individually identified.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Relevant Topic

Radiology
Radiology is the branch of medicine that studies imaging of the body; X-ray (basic, angiography, barium swallows), ultrasound, MRI, CT and PET. These imaging techniques can be used to diagnose, but also to treat a range of conditions, by allowing visuali...


Searches Linking to this Article