Advertisement

Topics

Secure two-party computation of solid triangle area and tetrahedral volume based on cloud platform.

08:00 EDT 13th June 2019 | BioPortfolio

Summary of "Secure two-party computation of solid triangle area and tetrahedral volume based on cloud platform."

With the emergence and widespread application of cloud computing, the use of cloud platforms to solve the problem of secure multi-party computation has emerged as a new research direction. The traditional computation of a solid geometry is performed through mutual interactions between two parties, which is not suitable in an untrusted cloud computing environment. In this paper, we first design a basic protocol for a secure Euclidean distance calculation that is suitable for cloud platforms and can serve as a building block for other protocols on cloud platforms. Using the solution of the Euclidean distance problem as such a building block, we provide a new method that converts the problems of calculating solid triangular areas and solid tetrahedral volumes into the calculation of distances and determinants in three-dimensional space. Then, we discuss solid point-line distance calculations, which extent the idea of the spatial geometry security problem. We present protocols for the above problems and prove that the proposed protocols can resist conspiracy among users and the untrusted cloud platform so that they can effectively ensure the privacy of the users. We also analyze the performances of these solutions. The analysis results show that our scheme is more versatile.

Affiliation

Journal Details

This article was published in the following journal.

Name: PloS one
ISSN: 1932-6203
Pages: e0217067

Links

DeepDyve research library

PubMed Articles [10801 Associated PubMed Articles listed on BioPortfolio]

Comparison of Accuracy of Left Atrial Area and Volume by Two-dimensional Trans-thoracic Echocardiography Versus Computed Tomography.

Left atrial (LA) size is prognostic of cardiovascular events and can be quantified as diameter, area, or volume. While LA area measurement by 2-dimensional (2D) echocardiography is performed by tracin...

Which is the ideal sanction for cooperation? An experimental study on different types of third-party sanctions.

Cooperation is the crux of many social problems, thus third-party sanction, as one of the most important ways to promote cooperation, is worth studying. The present study compared the effects of third...

Effects of cropping, smoothing, triangle count, and mesh resolution on 6 dental topographic metrics.

Dental topography is a widely used method for quantifying dental morphology and inferring dietary ecology in animals. Differences in methodology have brought into question the comparability of differe...

Anatomical Analysis of the Vagoaccessory Triangle and the Triangles Within: The Suprahypoglossal, Infrahypoglossal, and Hypoglossal-Hypoglossal Triangles.

Rootlets of the lower cranial nerves create a web that limits microsurgical maneuverability in the cerebellomedullary cistern (CMC). The vagoaccessory triangle (VAT) and 2 triangles within it were def...

Location of the Spinel Vacancies in γ-Al2O3.

A non-spinel model for the structure of γ-Al2O3, with 25% of the Al3+ cations at tetrahedral positions, has been the subject of wide interest. However, 17O NMR measurements and, more recently, 27Al N...

Clinical Trials [6349 Associated Clinical Trials listed on BioPortfolio]

Partially HLA-matched Third Party Antigen Specific T-cells for Infection Post-stem Cell or Solid Organ Transplantation

To assess the safety and biological efficacy of therapeutically administered most closely HLA-matched third party donor-derived specific cytotoxic T lymphocytes (CTLs) targeting cytomegalo...

Femoral Triangle and Adductor Canal Blocks Versus Femoral Nerve Block for Total Knee Arthroplasty

This prospective, double-blinded, randomized controlled study evaluates effects of femoral triangle and adductor canal blocks in comparison with femoral nerve block for primary total knee ...

Analgesic Effect of Adding an Adductor Canal Block to a Femoral Triangle Block for Total Knee Replacement

The aim of the study is to investigate whether the addition of an adductor canal block to a femoral triangle block will provide better analgesia for patients after total knee replacements.

Effects of Increased Tidal Volume on Internal Jugular Vein Cross-sectional Area

As increasing tidal volume, the cross sectional area and circumference of Internal Jugular Vein (IJV) could increase. And In the previous study, Trendelenburg position can increase size of...

Study of the Effect on Clinical Outcomes Using a Randomized Evaluation of Secure Text Messaging

In this study, the investigators will conduct a randomized, controlled trial to evaluate the impact of offering mobile secure text messaging on clinical outcomes.

Medical and Biotech [MESH] Definitions

The effort of two or more parties to secure the business of a third party by offering, usually under fair or equitable rules of business practice, the most favorable terms.

The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat).

The volume of air contained in the lungs at the end of a maximal inspiration. It is the equivalent to each of the following sums: VITAL CAPACITY plus RESIDUAL VOLUME; INSPIRATORY CAPACITY plus FUNCTIONAL RESIDUAL CAPACITY; TIDAL VOLUME plus INSPIRATORY RESERVE VOLUME plus functional residual capacity; or tidal volume plus inspiratory reserve volume plus EXPIRATORY RESERVE VOLUME plus residual volume.

Arrangements negotiated between a third-party payer (often a self-insured company or union trust fund) and a group of health-care providers (hospitals and physicians) who furnish services at lower than usual fees, and, in return, receive prompt payment and an expectation of an increased volume of patients.

The volume of the HEART, usually relating to the volume of BLOOD contained within it at various periods of the cardiac cycle. The amount of blood ejected from a ventricle at each beat is STROKE VOLUME.

Advertisement
Quick Search
Advertisement
Advertisement

 


DeepDyve research library

Searches Linking to this Article