A low-complexity and robust minimum variance beamformer for ultrasound imaging systems using beamspace dominant mode rejection.

08:00 EDT 21st August 2019 | BioPortfolio

Summary of "A low-complexity and robust minimum variance beamformer for ultrasound imaging systems using beamspace dominant mode rejection."

Minimum variance beamformer (MVB) has a high computational complexity that is mainly due to the inversion of an L×L covariance matrix involved during weight vector estimation, where L is the length of the subarray. In this work an attempt is made to reduce the computational complexity as well as increase the robustness against signal mismatch. The computational complexity is reduced by projecting the element-space data on to beamspace domain and then using dominant mode rejection on the beamspace covariance matrix (BCM). This reduces the dimension of covariance matrix and also eliminates the matrix inversion thereby reducing the computational complexity. Further, a closeness factor is introduced to determine the interference components that have to be suppressed, leading to increased robustness against signal mismatch. Performance of the proposed method has been evaluated on both simulated and experimental datasets. Results indicate that the proposed beamformer has a lateral resolution of 0.07 mm and a contrast resolution of 0.80, which are comparable to that of MVB which has a lateral and contrast resolution of 0.10 mm and 0.78, that too with a 12-fold reduction in computational complexity. The robustness of the peak magnitude estimate and spatial resolution of the beamformer with respect to error in estimation of sound velocity in the medium have also been evaluated. The variation in lateral resolution of proposed beamformer and MVB is approximately 1.21 mm and 1 mm. Further, the proposed beamformer has a maximum deviation in peak magnitude estimate of 0.7 dB whereas that of MVB is 2.5 dB, thus indicating the increased robustness of proposed method in peak magnitude estimate. Overall, the proposed beamformer has a 12-fold lower computational complexity compared to MVB with additional flexibility to increase the robustness against error in sound velocity.

Affiliation

Journal Details

This article was published in the following journal.

Name: Ultrasonics
ISSN: 1874-9968
Pages: 105979

Links

DeepDyve research library

PubMed Articles [17348 Associated PubMed Articles listed on BioPortfolio]

Fast adaptive beamforming through a cascade structure for ultrasound imaging.

A major limiting factor for applying a minimum variance (MV) beamformer in medical ultrasound imaging is its high computational complexity. This paper introduces a new fast MV beamforming method with ...

Image quality evaluation of ultrasound imaging systems: advanced B-modes.

The Quality assurance of ultrasound clinical imaging systems is essential for maintaining their performance to the highest level and for complying with the requirements by various regulatory and accre...

Ultrasound guidance in minimally invasive robotic procedures.

In the past decade, medical robotics has gained significant traction within the surgical field. While the introduction of fully autonomous robotic systems for surgical procedures still remains a chall...

Luminescence Lifetime Imaging of Chemical Sensors - a Comparison between Time-Domain and Frequency-Domain based Camera Systems.

Luminescence lifetime based imaging is still the most reliable method for generating chemical images using chemical sensor technology. However, only few commercial systems are available that enable im...

Facet joint degeneration adversely affects ultrasound imaging of the lumbar spine.

Ultrasound of neuraxis can be used to identify the best possible inter-spinous space to perform neuraxial block. The aim of this study was to assess the anatomical correlation between neuraxial ultra...

Clinical Trials [8937 Associated Clinical Trials listed on BioPortfolio]

Evaluation of a Binaural Beamformer (StereoZoom) in a Virtual Acoustic Environment and in Real Life

The goal of the study is to determine the benefit in speech intelligibility of the BBF and the MBF compared to an omni-directional microphone in different noise conditions. Secondary objec...

Evaluation and Optimization of PB127 Myocardial Perfusion Echocardiography on Ultrasound Systems

The purpose of this clinical trial is to evaluate various commercially available ultrasound systems and to identify imaging parameters to be used with these systems (along with the contras...

The ULTRA Study: Cross-Comparison of Ultrasound Systems

The purpose of this study is to develop computational methods for cross-comparison of muscle composition measurements in three laboratory ultrasound systems.

Ultrasound Elasticity Imaging of Venous Thrombi

The purpose of this study is to see if the investigators can use ultrasound imaging to determine the type of clots in patients to help better manage their care.

Optimizing the Technique of Embryo Transfer in IVF Using Better Imaging Guidance

This trial seeks to improve ultrasound imaging during embryo transfer in IVF by using a small, high resolution ultrasound probe used routinely for cardiac imaging in children.

Medical and Biotech [MESH] Definitions

The use of ultrasound to guide minimally invasive surgical procedures such as needle ASPIRATION BIOPSY; DRAINAGE; etc. Its widest application is intravascular ultrasound imaging but it is useful also in urology and intra-abdominal conditions.

The use of molecularly targeted imaging probes to localize and/or monitor biochemical and cellular processes via various imaging modalities that include RADIONUCLIDE IMAGING; ULTRASONOGRAPHY; MAGNETIC RESONANCE IMAGING; fluorescence imaging; and MICROSCOPY.

Non-invasive imaging methods based on the mechanical response of an object to a vibrational or impulsive force. It is used for determining the viscoelastic properties of tissue, and thereby differentiating soft from hard inclusions in tissue such as microcalcifications, and some cancer lesions. Most techniques use ultrasound to create the images - eliciting the response with an ultrasonic radiation force and/or recording displacements of the tissue by Doppler ultrasonography.

Use of ultrasound for imaging the breast. The most frequent application is the diagnosis of neoplasms of the female breast.

The visualization of deep structures of the body by recording the reflections of echoes of pulses of ultrasonic waves directed into the tissues. Use of ultrasound for imaging or diagnostic purposes employs frequencies ranging from 1.6 to 10 megahertz.

Quick Search


DeepDyve research library

Relevant Topic

Radiology
Radiology is the branch of medicine that studies imaging of the body; X-ray (basic, angiography, barium swallows), ultrasound, MRI, CT and PET. These imaging techniques can be used to diagnose, but also to treat a range of conditions, by allowing visuali...


Searches Linking to this Article