Topics

Speckle tracking derived reference values of myocardial deformation and impact of cardiovascular risk factors - Results from the population-based STAAB cohort study.

08:00 EDT 12th September 2019 | BioPortfolio

Summary of "Speckle tracking derived reference values of myocardial deformation and impact of cardiovascular risk factors - Results from the population-based STAAB cohort study."

We aimed to provide reference values for speckle-tracking derived systolic and diastolic myocardial deformation markers, and to determine their relation with age, sex, and cardiovascular risk factors.

Affiliation

Journal Details

This article was published in the following journal.

Name: PloS one
ISSN: 1932-6203
Pages: e0221888

Links

DeepDyve research library

PubMed Articles [20462 Associated PubMed Articles listed on BioPortfolio]

Speckle tracking echocardiographic deformation indices in Chagas and idiopathic dilated cardiomyopathy: Incremental prognostic value of longitudinal strain.

Chagas cardiomyopathy (CDC) is associated with a poor prognosis compared to other cardiomyopathies. Speckle tracking echocardiography (STE), which provides direct assessment of myocardial fiber deform...

Three-dimensional speckle-tracking echocardiography for evaluating myocardial motion in patients with cardiorenal syndrome.

Because of better awareness and understanding of its pathophysiology, the cardiorenal syndrome (CRS) is more often diagnosed and better managed. The echocardiographic evaluation of CRS now benefits fr...

Normal reference values of right atrial strain parameters using three-dimensional speckle-tracking echocardiography (results from the MAGYAR-Healthy Study).

Classic echocardiographic methodologies offer limited opportunities in assessing right atrial (RA) morphology and function. Three-dimensional (3D) speckle-tracking echocardiography (3DSTE) is a novel ...

Speckle Tracking Echocardiography - a New Tool for the Intensive Care Unit?

The noninvasive evaluation of cardiac morphology and function by echocardiography is an essential part of modern intensive care therapy. However, this procedure can be challenging and beginners often ...

CMR feature tracking in cardiac asymptomatic systemic sclerosis: Clinical implications.

Impaired myocardial deformation has been sporadically described in cardiac asymptomatic systemic sclerosis (SSc). We aimed to study myocardial deformation indices in cardiac asymptomatic SSc patients ...

Clinical Trials [8200 Associated Clinical Trials listed on BioPortfolio]

Comparison of Two Methods of Strain by Perioperative Transesophageal Echo in CABG : An Observational Study

There is an increasing need for diagnostic modalities able to objectively quantify myocardial function. Quantification of regional myocardial function with ultrasound is challenging on its...

The Use of Myocardial Deformation Imaging

Myocardial deformation imaging allows analysis of myocardial viability in ischemic left ventricular dysfunction. This study will evaluate the predictive value of myocardial deformation ima...

Detection of Myocardial Dysfunction in Non-severe Subarachnoid Hemorrhage (WFNS 1-2) Using Speckle-tracking Echocardiography (STRAIN)

Subarachnoid hemorrhage (SAH) can cause transient myocardial dysfunction. Recently, it have been reported that myocardial dysfunctions that occur in SAH are associated with poor outcomes. ...

Speckle Tracking Echocardiography Adds Information in Decompensated Heart Failure

The overall objective of the study is to determine whether speckle tracking echocardiography presents additional prognostic value to the routine assessment (clinical and echocardiographic)...

Global Longitudinal Peak Systolic Strain (GLPSS) Derived From Transesophageal Echocardiography - A Reliable Measure of Systolic Function?

Systolic function is a substantial determinant of overall hemodynamics and organ function. Therefore assessment of left ventricular systolic function (LVF) has been of central interest in...

Medical and Biotech [MESH] Definitions

Test results which deviate substantially from normal ranges of REFERENCE VALUES or other qualitative results. They trigger CLINICAL LABORATORY SERVICES to place a special alert to ensure PATIENT SAFETY.

Intraoperative computer-assisted 3D navigation and guidance system generally used in neurosurgery for tracking surgical tools and localize them with respect to the patient's 3D anatomy. The pre-operative diagnostic scan is used as a reference and is transferred onto the operative field during surgery.

The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality.

The complete summaries of the frequencies of the values or categories of a measurement made on a group of items, a population, or other collection of data. The distribution tells either how many or what proportion of the group was found to have each value (or each range of values) out of all the possible values that the quantitative measure can have.

A clinical syndrome defined by MYOCARDIAL ISCHEMIA symptoms; persistent elevation in the ST segments of the ELECTROCARDIOGRAM; and release of BIOMARKERS of myocardial NECROSIS (e.g., elevated TROPONIN levels). ST segment elevation in the ECG is often used in determining the treatment protocol (see also NON-ST ELEVATION MYOCARDIAL INFARCTION).

Quick Search


DeepDyve research library

Relevant Topic

Cardiovascular disease (CVD)
Acute Coronary Syndromes (ACS) Blood Cardiovascular Dialysis Hypertension Stent Stroke Vascular Cardiovascular disease (CVD) includes all the diseases of the heart and circulation including coronary heart disease (angina...


Searches Linking to this Article