Topics

Acoustic Scattering Mediated Single Detector Optoacoustic Tomography.

08:00 EDT 25th October 2019 | BioPortfolio

Summary of "Acoustic Scattering Mediated Single Detector Optoacoustic Tomography."

Optoacoustic image formation is conventionally based upon ultrasound time-of-flight readings from multiple detection positions. Herein, we exploit acoustic scattering to physically encode the position of optical absorbers in the acquired signals, thus reducing the amount of data required to reconstruct an image from a single waveform. This concept is experimentally tested by including a random distribution of scatterers between the sample and an ultrasound detector array. Ultrasound transmission through a randomized scattering medium was calibrated by raster scanning a light-absorbing microparticle across a Cartesian grid. Image reconstruction from a single time-resolved signal was then enabled with a regularized model-based iterative algorithm relying on the calibration signals. The signal compression efficiency is facilitated by the relatively short acquisition time window needed to capture the entire scattered wave field. The demonstrated feasibility to form an image using a single recorded optoacoustic waveform paves a way to the development of faster and affordable optoacoustic imaging systems.

Affiliation

Journal Details

This article was published in the following journal.

Name: Physical review letters
ISSN: 1079-7114
Pages: 174301

Links

DeepDyve research library

PubMed Articles [14915 Associated PubMed Articles listed on BioPortfolio]

Single Transparent Piezoelectric Detector for Optoacoustic Sensing-Design and Signal Processing.

In this article, we present a simple and intuitive approach to create a handheld optoacoustic setup for near field measurements. A single piezoelectric transducer glued in between two sheets of polyme...

Evaluation of balloon test occlusion before therapeutic carotid artery occlusion: Flat detector computed tomography cerebral blood volume imaging versus single-photon emission computed tomography.

We aimed to compare flat detector computed tomography cerebral blood volume (FD-CBV) imaging to single-photon emission computed tomography (SPECT) as an adjunctive technique during balloon test occlus...

Supercompliant and Soft (CH_{3}NH_{3})_{3}Bi_{2}I_{9} Crystal with Ultralow Thermal Conductivity.

In this Letter, we show the phonon dispersion of (CH_{3}NH_{3})_{3}Bi_{2}I_{9} single crystals at 300 K measured by inelastic x-ray scattering. The frequencies of acoustic phonons are among the lowes...

Determination of bisphenol analogues in food-contact plastics using diode array detector, charged aerosol detector and evaporative light-scattering detector.

Freshness protection packages and preservative films are widely used food-contact plastic made of polyethylene. Diode array detector (DAD), charged aerosol detector (CAD) and evaporative light-scatter...

Metal Artifact Reduction in Routine Chest and Abdominal Examinations Using Virtual Monoenergetic Images From Spectral Detector Computed Tomography.

The objective of this study was to investigate the quantitative and qualitative effects of virtual monoenergetic images (VMIs) by spectral detector computed tomography (SDCT) on metal artifacts in rou...

Clinical Trials [6401 Associated Clinical Trials listed on BioPortfolio]

Investigation of Plaque Instability Using Bevacizumab-800CW and MSOT

Determining whether we could visualize uptake of the fluorescent tracer Bevacizumab-800CW, targeting VEGF-A in atherosclerotic plaques by using the new imaging technique Multispectral Opto...

Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography

The purpose of this study is to evaluate the diagnostic accuracy of multi-detector computed tomography using 320 detectors for identifying the combination of coronary artery stenosis ≥ 5...

New Imaging Biomarkers for Muscular Diseases - Multispectral Optoacoustic Imaging in Spinal Muscular Atrophy

This study aims to refine the capability of MSOT to characterise muscle tissue and to determine non-invasive, quantitative biomarkers for the disease assessment in patients with spinal mus...

Non-invasive Imaging of Muscle Structure in Duchenne Muscular Dystrophy Using Multispectral Optoacoustic Tomography

This pilot study aims to assess subcellular muscle structure in patients with Duchenne X-linked progressive Duchenne muscular dystrophy (DMD) in comparison to healthy volunteers using mult...

Spectral Computed Tomography With Photon Counting Detector of Brain and Vessels.

Primary purpose of the study is to show wether computed tomography with photon counting detector has a diagnostic image quality as good as, or better than classic computed tomography in in...

Medical and Biotech [MESH] Definitions

Scattering of a beam of electromagnetic or acoustic RADIATION, or particles, at small angles by particles or cavities whose dimensions are many times as large as the wavelength of the radiation or the de Broglie wavelength of the scattered particles. Also know as low angle scattering. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Small angle scattering (SAS) techniques, small angle neutron (SANS), X-ray (SAXS), and light (SALS, or just LS) scattering, are used to characterize objects on a nanoscale.

An imaging technique using a device which combines TOMOGRAPHY, EMISSION-COMPUTED, SINGLE-PHOTON and TOMOGRAPHY, X-RAY COMPUTED in the same session.

Tomography using single-photon emitting RADIONUCLIDES to create images that are captured in times corresponding to various points in the cardiac cycle.

Types of spiral computed tomography technology in which multiple slices of data are acquired simultaneously improving the resolution over single slice acquisition technology.

An imaging technique using compounds labelled with short-lived positron-emitting radionuclides (such as carbon-11, nitrogen-13, oxygen-15 and fluorine-18) to measure cell metabolism. It has been useful in study of soft tissues such as CANCER; CARDIOVASCULAR SYSTEM; and brain. SINGLE-PHOTON EMISSION-COMPUTED TOMOGRAPHY is closely related to positron emission tomography, but uses isotopes with longer half-lives and resolution is lower.

Quick Search


DeepDyve research library

Relevant Topics

Radiology
Radiology is the branch of medicine that studies imaging of the body; X-ray (basic, angiography, barium swallows), ultrasound, MRI, CT and PET. These imaging techniques can be used to diagnose, but also to treat a range of conditions, by allowing visuali...

Diagnostics
A diagnostic test is any kind of medical test performed to aid in the diagnosis or detection of disease. For example: to diagnose diseases to measure the progress or recovery from disease to confirm that a person is free from disease Clin...

Mergers & Acquisitions
Commercial and market reports on mergers and acquisitions in the biotechnology, pharmaceutical, medical device and life-science industries. Mergers and acquisitions (abbreviated M&A;) is an aspect of corporate strategy, corporate finance and manageme...


Searches Linking to this Article