Topics

Local magnetic flux density measurements for temperature control of transient and non-homogeneous processing of steels.

07:00 EST 29th November 2019 | BioPortfolio

Summary of "Local magnetic flux density measurements for temperature control of transient and non-homogeneous processing of steels."

Measuring temperatures during high-temperature processing of steels is usually limited to surface measurements that cannot directly assess the internal temperature distribution. Here, we demonstrate the feasibility of using a magnetic flux density measurement system to assess transient and non-homogeneous temperature fields in a modern high-strength steel, within the intercritical temperature range where microstructural evolution defines their key mechanical properties. The system accurately detects the Curie temperature and distinguishes temperature change rates within the processed volume. The magnetic measurements are also sensitive to the volume above Curie temperature and its shape, as revealed when integrated with thermal computational simulations. The electromagnetic signal provides real-time qualitative and quantitative information relevant to the metallurgical conditions enabling future intelligent control systems for the production and processing of steels. Contactless measurements of temperature-dependent electromagnetic properties can enable through-thickness temperature monitoring solutions, opening up opportunities for non-destructive full-field imaging of steels during thermal and thermomechanical processing.

Affiliation

Journal Details

This article was published in the following journal.

Name: Scientific reports
ISSN: 2045-2322
Pages: 17900

Links

DeepDyve research library

PubMed Articles [26396 Associated PubMed Articles listed on BioPortfolio]

Zero-heat-flux core temperature monitoring system: an observational secondary analysis to evaluate agreement with naso-/oropharyngeal probe during anesthesia.

General anesthesia impairs thermoregulation and contributes to perioperative hypothermia; core body temperature monitoring is recommended during surgical procedures lasting > 30 min. Zero-heat-flux...

Magnetic and Electrocatalytic Properties of Nanoscale Cobalt Boride, CoB.

The use of low-temperature solution synthesis followed by a brief annealing step allows metastable single-phase CoB nanoparticles to be obtained, with sizes ranging from 11 to 22 nm. The particles are...

Electric readout of magnetic stripes in insulators.

In superconductors, a topological configuration of the superconducting order parameter called a superconducting vortex carries magnetization. Such a magnetic topological object behaves like a minute p...

Tensile-Stress Dependence of Magnetic Hysteresis Properties Measured by the Acoustically Stimulated Electromagnetic Response in Steel.

Magnetic hysteresis properties are sensitive to stress in ferromagnetic materials. This suggests that magnetic measurements are a potential method to evaluate residual stress in steel products. Nevert...

Low Dimensional Magnetic Lattice and Room Temperature Magneto(di)electric Effect in Polyanion Ruddlesden-Popper Iron Oxides.

We have shown a new design strategy which exploits different oxyanions in a Ruddlesden-Popper (RP)-type phase to modulate the local crystal structure and magnetic lattice. Material (SrFe(SO)O) with th...

Clinical Trials [12816 Associated Clinical Trials listed on BioPortfolio]

Central Temperature Monitoring by Zero-heath-flux a Non-invasive Technic Compared to Two Invasive Technic During Surgery

Core temperature monitoring is mandatory during major surgery. The accurate techniques currently used are invasive, such as artery catheter and oesophagal probe. A new non-invasive cutaneo...

Hypothermia in Cesarean Sectio Patients in Regional Anaesthesia

To study the core temperature perioperatively in patients due for elective cesarean sectio in spinal anaesthesia. Core temperature will be registered by a zero-flux (SpotOn. 3m) probe on ...

Can the SpotOn™ Zero-Heat-Flux-Thermometry Sensor Accurately Measure Core Temperature in Children?

The present study aims to assess the accuracy of the SpotOn™ Zero-heat-flux-thermometry sensor in measuring core temperature in the paediatric population in the perioperative period.

Comparison Between Non-invasive Heat-flux and Invasive Core Temperature Monitoring

The body core temperature drops during general anesthesia. To maintain homeostasis, patients require warming measures. Different methods to measure body core temperature exist, which are e...

Evaluation of the Tyto Thermometer When Used in Clinical Care Setting

Patients who present to the Emergency Department will be evaluated for eligibility to the study. Those meeting all the inclusion criteria and none of the exclusion criteria will undergo an...

Medical and Biotech [MESH] Definitions

Measurement of the temperature of a material, or of the body or an organ by various temperature sensing devices which measure changes in properties of the material that vary with temperature, such as ELASTICITY; MAGNETIC FIELDS; or LUMINESCENCE.

The ability of an element or metallic alloy to allow the passage of ELECTRONS without ELECTRICAL RESISTANCE and expel MAGNETIC FIELDS below a certain threshold temperature called superconducting transition temperature.

The ratio of the density of a material to the density of some standard material, such as water or air, at a specified temperature.

The processes of heating and cooling that an organism uses to control its temperature.

An NADPH oxidase that is expressed by PHAGOCYTES where it transfers electrons across the plasma membrane from cytosolic NADPH to molecular oxygen on the exterior. It regulates proton (H+) flux into resting phagocytes to control intracellular pH. Mutations in the CYBB gene are associated with X-LINKED CHRONIC GRANULOMATOUS DISEASE.

Quick Search


DeepDyve research library

Searches Linking to this Article