Calibration and measurement analysis of a cloud particle detection system based on polarization detection.

07:00 EST 20th December 2019 | BioPortfolio

Summary of "Calibration and measurement analysis of a cloud particle detection system based on polarization detection."

The phase state information of cloud water is important for the airborne measurement of the microphysical properties of a cloud. A cloud particle detection system based on polarization detection, which can be used to detect the size and phase state of cloud particles for particle diameters of less than 50 µm, was developed by detecting the energy of the forward scattering and the depolarization of backscattered light. The sensitive area was calculated through the width and depth of the field of view of the laser beam. The system was calibrated using standard particles. The response curve of the system to the cloud particles was obtained by calculating the relationship between the standard particles and the cloud droplets. Finally, the liquid droplets and typical nonspherical particles were measured, and the results compared with a simulation. The comparison results indicated that the system could detect spherical and nonspherical cloud particles and could discriminate between nonspherical cloud particles and liquid droplets.

Affiliation

Journal Details

This article was published in the following journal.

Name: Applied optics
ISSN: 1539-4522
Pages: 9777-9785

Links

DeepDyve research library

PubMed Articles [44042 Associated PubMed Articles listed on BioPortfolio]

Measurement of cloud particles in a cloud chamber based on interference technology.

Based on interference technology, a cloud particle measurement system is designed. The scattering angle of the system is selected as 90°. The iterative mean filter algorithm is modified, and the syst...

DEVELOPMENT OF A PELTIER TYPE CLOUD CHAMBER WITH WIDE VIEW FIELD.

Cloud chamber contributes to radiation education by facilitating observation of particle tracks formed by radiation. Peltier-based chamber achieves cooling without the need for dry ice,. we developed ...

Generalized MPI Multi-Patch Reconstruction using Clusters of similar System Matrices.

The tomographic imaging method magnetic particle imaging (MPI) requires a multi-patch approach for capturing large field of views. This approach consists of a continuous or stepwise spatial shift of a...

Upper limb joint kinematics using wearable magnetic and inertial measurement units: an anatomical calibration procedure based on bony landmark identification.

The estimate of a consistent and clinically meaningful joint kinematics using wearable inertial and magnetic sensors requires a sensor-to-segment coordinate system calibration. State-of-the-art calibr...

Dynamic calibration method of the laser beam for a non-orthogonal shaft laser theodolite measurement system.

The non-orthogonal shaft laser theodolite (N-theodolite) measurement system is a new kind of instrument applied to large-scale metrology. The system consists of two identical N-theodolites, each of wh...

Clinical Trials [16048 Associated Clinical Trials listed on BioPortfolio]

Endoscopic vs. Suction Device Calibration in Sleeve Gastrectomy

This study aims to compare the difference in staple usage and post-operative GERD (heartburn) between patients that had an endoscope used versus patients that had a suction calibration sys...

NightOwl SpO2 Calibration Study

Calibration of a software module that computes Oxygen saturation(SpO2) based on photoplethysmography (PPG) traces acquired by the NightOwl reflectance-based PPG sensor which is placed on t...

Development of an Screening System in Children With Congenital Heart Disease Based on Cloud Computing and Big Data

This study intends to establish an automatic system for screening on children with congenital heart disease, the system include the auscultation of cardiac murmur and the test of oxygen sa...

Spirometry Using Electrical Impedance Tomography

The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal i...

Innovative SolutIons for DosimEtry in Hadrontherapy (INSIDE)

The study aim is to test the clinical feasibility and effectiveness of an online qualitative monitoring device named INSIDE system during hadrontherapy treatments. This instrumentation is...

Medical and Biotech [MESH] Definitions

A method of chemical analysis based on the detection of characteristic radionuclides following a nuclear bombardment. It is also known as radioactivity analysis. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed)

Fluoroimmunoassay where detection of the hapten-antibody reaction is based on measurement of the increased polarization of fluorescence-labeled hapten when it is combined with antibody. The assay is very useful for the measurement of small haptenic antigens such as drugs at low concentrations.

Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output.

Measurement of blood flow based on induction at one point of the circulation of a known change in the intravascular heat content of flowing blood and detection of the resultant change in temperature at a point downstream.

Methods for performing three-dimensional measurement and motion analysis using stereoscopic radiographs.

Quick Search


DeepDyve research library

Searches Linking to this Article