Topics

Time-space Fourier κω' filter for motion artifacts compensation during transcranial fluorescence brain imaging.

07:00 EST 13th February 2020 | BioPortfolio

Summary of "Time-space Fourier κω' filter for motion artifacts compensation during transcranial fluorescence brain imaging."

Intravital imaging of brain vasculature through the intact cranium in vivo is based on the evolution of the fluorescence intensity and provides an ability to characterize various physiological processes in the natural context of cellular resolution. The involuntary motions of the examined subjects often limit in vivo non-invasive functional optical imaging. Conventional imaging diagnostic modalities encounter serious difficulties in correction of artificial motions, associated with the rapid structural variations and fast high dynamics of the intensity values in the collected image sequences, when a common reference cannot be provided. In the current report, we introduce an alternative solution based on a time-space Fourier transform method so-called Kappa-Omega. We demonstrate that the proposed approach is effective for image stabilization of fast dynamic image sequences and can be used autonomously without supervision and assignation of a reference image.

Affiliation

Journal Details

This article was published in the following journal.

Name: Physics in medicine and biology
ISSN: 1361-6560
Pages:

Links

DeepDyve research library

PubMed Articles [12701 Associated PubMed Articles listed on BioPortfolio]

Correction of respiratory artifacts in MRI head motion estimates.

Head motion represents one of the greatest technical obstacles in magnetic resonance imaging (MRI) of the human brain. Accurate detection of artifacts induced by head motion requires precise estimatio...

Retrospective motion compensation for edited MR spectroscopic imaging.

Edited magnetic resonance spectroscopic imaging (MRSI) is capable of mapping the distribution of low concentration metabolites such as gamma-aminobutyric acid (GABA) or glutathione (GSH), but is prone...

MR-MOTUS: model-based non-rigid motion estimation for MR-guided radiotherapy using a reference image and minimal k-space data.

Time-resolved motion estimation from MRI data has received an increasing amount of interest due to the advent of the MR-Linac. The combination of an MRI scanner and a linear accelerator enables radiat...

Graph Embedding Using Frequency Filtering.

The target of graph embedding is to embed graphs in vector space such that the embedded feature vectors follow the differences and similarities of the source graphs. In this paper, a novel method name...

Newly Developed Methods for Reducing Motion Artifacts in Pediatric Abdominal MRI: Tips and Pearls.

The purpose of this article is to review established and emerging methods for reducing motion artifacts in pediatric abdominal MRI. Clearly understanding the strengths and limitations of motion reduc...

Clinical Trials [3679 Associated Clinical Trials listed on BioPortfolio]

Effect of Metal Artifacts Reduction Orotocols and Electric Potential Difference on Metal Artifacts in Cone Beam Computed Tomography

The effect of metal artifacts reduction protocols and tube potential difference on the metallic artifacts in cone beam computed tomography

The Incidence of Artifacts in the Anesthesia Information Management System Database.

The purpose of the study is to evaluate the incidence of artifacts in the developed AIMS database

Using a Novel Algorithm to Improve the Retrieval Rate of Inferior Vena Cava Filters (iRetrieve Study)

Since 2003, that the first retrievable IVC filter was introduced in the U.S,improvements have been made in the filter design to resolve problems of structural integrity and increase the...

Recovery Filter Study (EVEREST)

This study was designed to assess the safety of retrieval of the Bard Recovery® G2® Filter System. The G2 filter is an FDA-cleared device for inferior vena caval interruption in patients...

Retrievability and Incidence of Complex Retrieval in Celect Versus Denali Filter

The primary purpose of this study is to compare the Celect and Denali filters in terms of complicated filter retrieval and indwelling complications after a 2-month indwelling time.

Medical and Biotech [MESH] Definitions

A statistically significant excess of cases of a disease, occurring within a limited space-time continuum.

Disorder caused by motion, as sea sickness, train sickness, car sickness, air sickness, or SPACE MOTION SICKNESS. It may include nausea, vomiting and dizziness.

Analysis based on the mathematical function first formulated by Jean-Baptiste-Joseph Fourier in 1807. The function, known as the Fourier transform, describes the sinusoidal pattern of any fluctuating pattern in the physical world in terms of its amplitude and its phase. It has broad applications in biomedicine, e.g., analysis of the x-ray crystallography data pivotal in identifying the double helical nature of DNA and in analysis of other molecules, including viruses, and the modified back-projection algorithm universally used in computerized tomography imaging, etc. (From Segen, The Dictionary of Modern Medicine, 1992)

Disorder characterized by nausea, vomiting, and dizziness, possibly in response to vestibular disorientation or fluid shifts associated with space flight. (From Webster's New World Dictionary)

Timing the acquisition of imaging data to specific points in the cardiac cycle to minimize image blurring and other motion artifacts.

Quick Search


DeepDyve research library

Searches Linking to this Article