Topics

PubMed Journal Database | Operative dentistry RSS

15:53 EDT 30th March 2020 | BioPortfolio

The US National Library of Medicine and National Institutes of Health manage PubMed.gov which comprises of more than 29 million records, papers, reports for biomedical literature, including MEDLINE, life science and medical journals, articles, reviews, reports and  books.

BioPortfolio aims to cross reference relevant information on published papers, clinical trials and news associated with selected topics - speciality.

For example view all recent relevant publications on Epigenetics and associated publications and clincial trials.

Showing PubMed Articles 1–25 of 234 from Operative dentistry

Conservative Tooth Preparation, Minimal Intervention, and/or Narrow-parallel Preparations: A Narrative.

Is Conventional Resin Cement Adhesive Performance to Dentin Better Than Self-adhesive? A Systematic Review and Meta-Analysis of Laboratory Studies.

This study aimed to conduct a systematic review of the literature on laboratory studies assessing bonding performance to dentin of conventional and self-adhesive resin cements, in cementing indirect restorations. This review was reported according to the PRISMA Statement. Of a total of 518 studies, 36 were screened full text and reviewed according to exclusion criteria. Nineteen papers were included in the systematic review and meta-analyses, according to the following inclusion criteria: studies that evalu...

Effect of Methacryloyloxydecyl Dihydrogen Phosphate-Containing Silane and Adhesive Used Alone or in Combination on the Bond Strength and Chemical Interaction With Zirconia Ceramics Under Thermal Aging.

To evaluate the effect of a methacryloyloxydecyl dihydrogen phosphate (MDP)-containing silane coupling agent and universal adhesive, used alone or in combination, on the microshear bond strength (μSBS) to zirconia after 24 hours of water storage (24h) and after 10,000 thermocycles (TC), complemented with chemical analysis of the surface to establish the presence of MDP on the surface of the zirconia after bonding procedures.

An Improved Direct Injection Technique With Flowable Composites. A Digital Workflow Case Report.

This article presents a clinical technique based on a case report for restoring the contours and shape of the upper teeth involved in the smile display of a young patient. After planning the treatment for the patient using digital tools (Digital pictures, Digital Smile Design, digital waxup, three-dimensional [3D] printed models, mockup), the upper teeth were restored using an improved injection technique. This improved technique involves the direct injection of flowable composite resin using clear polyviny...

Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites.

To evaluate volumetric polymerization shrinkage (VPS), shear bond strength (SBS) to dentin, and cohesive tensile strength (CTS) of bulk-fill resin composites (BFRCs) light activated by different modes.

Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis.

This study determined the effect of dietary solvents on the surface roughness (Ra) of direct, indirect, and computer-aided design/computer-aided manufacturing (CAD/CAM) dental composites. The materials evaluated were a direct composite (Filtek Z350 XT [FZ]), an indirect composite (Shofu Ceramage [CM]), and four CAD/CAM composites (Lava Ultimate [LU], Shofu Block HC [HC], Cerasmart [CS], and Vita Enamic [VE]). Specimens (12×14×1.5 mm) of each material were prepared, measured for baseline Ra, ranked, divide...

Fracture Resistance and Failure Mode of Custom-made Post-and-cores of Polyetheretherketone and Nano-ceramic Composite.

The purpose of this study was to evaluate the fracture resistance and failure mode of custom-made post-and-cores manufactured with different esthetic materials.

Molar Incisor Hypomineralization: Etiology, Clinical Aspects, and a Restorative Treatment Case Report.

Molar-incisor hypomineralization (MIH) is a condition that negatively affects enamel and dentin, especially the first molars and permanent incisors, causing esthetic and functional problems. The present clinical case report presents and discusses the etiology and clinical characteristics of MIH and describes a restorative protocol for MIH-affected teeth.

Effect of Various Surface Treatments on Ti-Base Coping Retention.

The titanium-cement interface of a Ti-Base implant crown must be able to resist intraoral pull-off forces. The purpose of this study was to evaluate the effect of mechanical and chemical surface treatments of a titanium-abutment base (Ti-Base, Dentsply/Sirona) on the pull-off bond strength of a lithium disilicate abutment coping.

Bioactive Materials Subjected to Erosion/Abrasion and Their Influence on Dental Tissues.

The objective of this study was to evaluate the effect of erosion or erosion-abrasion on bioactive materials and adjacent enamel/dentin areas.

Two-year Follow-up of Ceramic Veneers and a Full Crown Treated With Self-etching Ceramic Primer: A Case Report.

The use of the self-etching ceramic primer combines the stages of acid conditioning and silanization in cementation procedures of ceramic restorations. The protocol is a simpler and safer alternative to the conventional protocol for surface treatment of silica-based ceramics. This case report describes the steps of an esthetic rehabilitation with ultrathin veneers and full crown based on lithium disilicate treated with a ceramic primer (Monobond Etch & Prime, Ivoclar Vivadent, Schaan, Liechtenstein). After ...

Physical Properties of Nanohybrid and Microhybrid Resin Composites Subjected to an Acidic Environment: A Laboratory Study.

This study investigated the hardness and color stability of five resin composites subjected to different polishing methods following immersion in distilled water or lactic acid for up to three months.

Pure Ormocer vs Methacrylate Composites on Posterior Teeth: A Double-blinded Randomized Clinical Trial.

The aim of this study was to evaluate the clinical performance of class II restorations made using pure ormocer and methacrylate composites in a period of 24 months, using a split-mouth double-blinded randomized design.

Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in Molar Teeth.

This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth.

Wear Properties of Different Additive Restorative Materials Used for Onlay/Overlay Posterior Restorations.

The purpose of this laboratory study was to compare the two-body wear resistance of different restorative materials commonly used for the indirect restoration of posterior teeth. The tested materials, based on ceramic (Imagine Press X, IPS e.max CAD, Milled Celtra Duo, Glaze-Fired Celtra Duo, Vita Mark II) and composite (Enamel Plus HRi, Enamel Plus HRi Bio-Function, Filtek Supreme XTE, Lava Ultimate), were compared with the wear properties of a type III gold alloy (Aurocast 8). Flat samples were prepared w...

Endodontic Access Effect on Full Contour Zirconia and Lithium Disilicate Failure Resistance.

To evaluate the effect of endodontic access on the failure load resistance of both adhesively and conventionally luted, full-contour monolithic yttria-stabilized zirconium dioxide (Y-TZP) and adhesively luted lithium disilicate (LD) crowns cemented on prepared teeth.

Do Tooth- and Cavity-related Aspects of Noncarious Cervical Lesions Affect the Retention of Resin Composite Restorations in Adults? A Systematic Review and Meta-analysis.

The purpose was to perform a systematic review and meta-analysis based on the following research question: do tooth- and cavity-related aspects of noncarious cervical lesions (NCCLs) affect the retention of composite restorations?

A Comparative Study of Light Transmission by Various Dental Restorative Materials and the Tooth Structure.

This study aims to quantify and compare the amount of light that passes through seven different types of direct and indirect restorative materials comprising light-cured resin based composites (regular and bulk-fill), computer-aided design/computer-aided manufacturing (CAD/CAM) restoratives such as resin based composites, poly(methyl methacrylate) (PMMA) resin, leucite glass-ceramic, lithium silicate glass-ceramic, feldspar ceramic, and the natural tooth structure.

Dentin Staining Caused by Nano-Silver Fluoride: A Comparative Study.

The objective of this study was to evaluate the dentin staining potential of nano-silver fluoride (NSF 600 and 1500 ppm) compared with the following commercially available cariostatic agents: Advantage Arrest (Elevate Oral Care, West Palm Beach, FL, USA), Riva Star (SDI, Victoria, Australia), and Cariestop (Biodinâmica, Paraná, Brazil). Seventy-five extracted human molars were sectioned at the cementoenamel junction, and the occlusal enamel was removed for exposure of coronary dentin. The samples were div...

The Dental Amalgam Phasedown in New Zealand: A 20-year Trend.

Information on the choice of material and performance of restorations placed in a dental practice annually is limited. The Minamata Convention on Mercury is likely to affect the use of amalgam worldwide. The objective of this research was to investigate the use of restorative materials at the University of Otago Faculty of Dentistry in New Zealand from 1998 to 2017.

Clinical Effects of Desensitizing Prefilled Disposable Trays in In-office Bleaching: A Randomized Single-blind Clinical Trial.

This study aimed to evaluate the desensitizing effect of a prefilled disposable tray containing potassium nitrate and fluoride on the self-reported tooth sensitivity (TS) and the bleaching efficacy of 40% hydrogen peroxide bleaching agent used for in-office bleaching in comparison with potassium nitrate and fluoride gel applied in a conventional-delivered tray system in an equivalence clinical trial.

Influence of Computer-aided Design/Computer-aided Manufacturing Diamond Bur Wear on Marginal Misfit of Two Lithium Disilicate Ceramic Systems.

This laboratory study aimed to assess the effect of successive crown millings on the marginal misfit of monolithic full-ceramic restorations obtained from two lithium disilicate systems, with a single diamond bur set used for each material in a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) unit.

A Conservative Approach to Ceramic Veneers: A Case Report.

Bonding to enamel has been shown to provide reliable results, and thus conservative tooth preparations are key to the success of ceramic bonded restorations. The wax-up is the first diagnostic tool available to evaluate discrepancies between current and ideal tooth proportions. The clinician's diagnostic mock-up provides the patient with a visual perception of the size and shape of the proposed restorations. The use of reduction guides assists the restorative dentist in evaluating the specific amount of too...

Differences in Radiopacity, Surface Properties, and Plaque Accumulation for CAD/CAM-Fabricated vs Conventionally Processed Polymer-based Temporary Materials.

To test computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated and conventionally processed polymer-based temporary materials in terms of radiopacity (RO), surface free energy (SFE), surface roughness (SR), and plaque accumulation (PA).

Fatigue Failure Load of a Bonded Simplified Monolithic Feldspathic Ceramic: Influence of Hydrofluoric Acid Etching and Thermocycling.

To evaluate the effect of hydrofluoric acid (HF) etching and thermocycling (Tc) on fatigue failure load of feldspathic ceramic restorations cemented with two resin cements.


Quick Search