PubMed Journals Articles About "Aesculap Implant Systems" RSS

04:49 EDT 19th March 2018 | BioPortfolio

Aesculap Implant Systems PubMed articles on BioPortfolio. Our PubMed references draw on over 21 million records from the medical literature. Here you can see the latest Aesculap Implant Systems articles that have been published worldwide.

More Information about "Aesculap Implant Systems" on BioPortfolio

We have published hundreds of Aesculap Implant Systems news stories on BioPortfolio along with dozens of Aesculap Implant Systems Clinical Trials and PubMed Articles about Aesculap Implant Systems for you to read. In addition to the medical data, news and clinical trials, BioPortfolio also has a large collection of Aesculap Implant Systems Companies in our database. You can also find out about relevant Aesculap Implant Systems Drugs and Medications on this site too.

Showing "Aesculap Implant Systems" PubMed Articles 1–25 of 9,100+

Immediate mechanical stability of threaded and porous implant systems.

Primary stability of a dental implant system is an essential factor to maintain its long-term success. Thus, the objective of this study was to examine whether primary stability is different between threaded and porous dental implant systems placed in artificial bone blocks and human cadaveric mandibular bone.

Association Between Implant-Abutment Microgap and Implant Circularity to Bacterial Leakage: An In Vitro Study Using Tapered Connection Implants.

The aim of this study was to evaluate the microgap between the abutment and implant as well as the circularity of implant platforms and associating conformational errors with bacterial microleakage in tapered connection implant systems.

Effects of Osteotomy Lengths on the Temperature Rise of the Crestal Bone During Implant Site Preparation.

To compare temperatures of the crestal bone during implant site preparation for different osteotomy lengths and implant systems.

Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems.

To evaluate the changes in the external-hexagon surface of the titanium (Ti) implant before and after mechanical cycling, when coupled with zirconia (Zr) abutments (A) manufactured by three computer-aided design/computer-aided manufacturing (CAD/CAM) systems (Neodent Digital, Zirkonzahn, and AmannGirrbach) and the ZrTi abutment manufactured by Neodent.

New innovative method relating guided surgery to dental implant placement.

Companies selling dental implant guided systems mostly offer similar surgical guides. The purpose of this paper is to present an innovative guided surgery system which originality lies in its guidance device, and to report the author's experience in using this system for dental implant surgery.

Do Sealing Materials Influence Superstructure Attachment in Implants?

This study aimed to evaluate the possible effect of sealing materials on superstructure attachment (ie, tightening/loosening torque and implant-abutment gap) in two different implant systems.

Comparison of different maintenance strategies within supportive implant therapy for prevention of peri-implant inflammation during the first year after implant restoration. A randomized, dental hygiene practice-based multicenter study.

This randomized clinical multicenter study compared different professional preventive approaches on peri-implant inflammation under supportive implant therapy (SIT).

Optical Coherence Tomography in Patients With the Subretinal Implant Retina Implant Alpha IMS.

The aim of this study was to assess changes in retinal structure and thickness after subretinal implantation of the Retina Implant Alpha IMS (Retina Implant AG, Reutlingen, Germany).

Fatigue Failure of External Hexagon Connections on Cemented Implant-Supported Crowns.

To evaluate the probability of survival and failure modes of different external hexagon connection systems restored with anterior cement-retained single-unit crowns. The postulated null hypothesis was that there would be no differences under accelerated life testing.

Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations.

Polyethylene Damage Increases With Varus Implant Alignment in Posterior-stabilized and Constrained Condylar Knee Arthroplasty.

Implant malalignment in primary TKA has been reported to increase stresses placed on the bearing surfaces of implant components. We used a longitudinally maintained registry coupled with an implant retrieval program to consider whether preoperative, postoperative, or prerevision malalignment was associated with increased risk of revision surgery after TKA.

Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study.

This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph.

Irregular Implant Design Decreases Periimplant Stress and Strain Under Oblique Loading.

To investigate whether a different implant geometry with the same potential contact surface area (PCSA) affects the principal stress and strains in bone.

Diagnostic accuracy of 4 intraoral radiographic techniques for misfit detection at the implant abutment joint.

A misfit or gap at the implant-abutment joint (IAJ) requires detection as it may compromise the health of the peri-implant tissue. However, which radiographic technique provides the most orthogonal relationship between the central beam and the implant/image receptor is unclear.

A Survey of Dental Implant Instruction in Predoctoral Dental Curricula in North America.

The aim of this study was to investigate the extent and forms of predoctoral implant dentistry instruction in North American dental schools and to identify future directions and challenges. The survey collected data on curriculum content, departmental oversight, techniques, and materials, as well as current problems to be solved. The 30-question survey was sent in 2012 to the dean or administrator in charge of the predoctoral curriculum of all 73 dental schools in the U.S. and Canada at the time; four remin...

Clinical Evidence of OsseoSpeed EV Implants: A Retrospective Study and Characterization of the Newly Introduced System.

This retrospective study sought to compare a new implant (Astra Tech OsseoSpeed EV) with its predecessor (Astra Tech OsseoSpeed TX) by scanning electron microscopy and interferometry. Radiographic data from 19 patients who underwent implant restoration with EV (n = 49) with a median follow-up of 16 months were evaluated for mean bone level (MBL) changes from delivery of the definitive prosthesis. EV and TX did not differ in surface roughness, and both systems had a tight seal at the implant-abutment interfa...

The influence of crown-to-implant ratio on marginal bone levels around splinted short dental implants: A radiological and clincial short term analysis.

The amount of marginal bone resorption around dental implants is considered to have a significant impact on implant stability as well as implant survival rates.

Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 2: Palateless Dentures.

Palateless maxillary implant overdentures are often used for patients experiencing problems with a full-palate denture. However, palateless overdentures are reported to be a risk factor for implant complications. The purpose of this study was to examine the strain on implants beneath palateless overdentures with unsplinted attachments under various implant distributions.

Patient-Specific Guides/Instrumentation in Shoulder Arthroplasty.

Optimal outcomes following total shoulder arthroplasty TSA and reverse shoulder arthroplasty RSA are dependent on proper implant position. Multiple cadaver studies have demonstrated improved accuracy of implant positioning with use of patient-specific guides/instrumentation compared to traditional methods. At this time, there are 3 commercially available single use patient-specific instrumentation systems and 1 commercially available reusable patient-specific instrumentation system. Currently though, there ...

Single-Dose Bioavailability for Prophylactic Coverage in Patients Undergoing Dental Implant Surgery.

The use of antibiotic prophylaxis in dental implant surgery is a routine dental practice to prevent implant failure. Current systematic reviews have yet to confirm the effectiveness of antibiotic treatment at reducing postoperative infection rates in implant procedures. The aim of this study was to quantify amoxicillin plasma levels at the peripheral venous blood and at the surgical implant site in patients undergoing dental treatment.

Effect of Submerged vs Nonsubmerged Implant Placement Protocols on Implant Failure and Marginal Bone Loss: A Systematic Review and Meta-Analysis.

To compare prosthesis and implant failures and marginal bone loss (MBL) resulting from submerged vs nonsubmerged dental implant protocols.

Computer guided sinus floor elevation through lateral window approach with simultaneous implant placement.

The introduction of CAD/CAM technology in implant dentistry has marked a new era, allowing various procedures to be carried out with a level of great precision and accuracy.

Immediate One-Time Low-Profile Abutment to Enhance Peri-implant Soft and Hard Tissue Stability in the Esthetic Zone.

Reductions in peri-implant bone height have been acknowledged as a normal consequence of implant therapy. Various restorative factors contribute to this phenomenon. One is repeated abutment retightening, which causes a mechanical disruption at the implant-abutment interface, leading to soft tissue recession. Several investigators proposed placement of the definitive abutment after implant placement as a solution to the problem. The definitive use of an intermediate abutment after implant placement seems to ...

The Effect of Implant-Induced Artifacts on Interpreting Adjacent Bone Structures on Cone-Beam Computed Tomography Scans.

Cone-beam computed tomography (CBCT) imaging can be used to visualize anatomical structures before implant placement. The aim of this study is to evaluate the impact of implant artifacts on the accuracy of measuring periimplant bone dimensions.

Incidence and Management of Fractured Dental Implants: Case Reports.

The fracture of dental implants is a rare occurrence in clinical settings. Possible causes of implant fracture include design or production flaws, overloaded occlusion force, implant location, metal fatigue, and bone resorption around the implant. This study reports on the successful removal and reimplantation of fractured implants.

Quick Search