We have published hundreds of Elekta news stories on BioPortfolio along with dozens of Elekta Clinical Trials and PubMed Articles about Elekta for you to read. In addition to the medical data, news and clinical trials, BioPortfolio also has a large collection of Elekta Companies in our database. You can also find out about relevant Elekta Drugs and Medications on this site too.

Showing "Elekta" PubMed Articles, all 12

Monte Carlo and analytic modeling of an Elekta Infinity linac with Agility MLC: Investigating the significance of accurate model parameters for small radiation fields.

To explain the deviation observed between measured and Monaco calculated dose profiles for a small field (i.e., alternating open-closed MLC pattern). A Monte Carlo (MC) model of an Elekta Infinity linac with Agility MLC was created and validated against measurements. In addition, an analytic model which predicts the fluence at the isocenter plane was used to study the impact of multiple beam parameters on the accuracy of dose calculations for small fields.


Remote dosimetric auditing of clinical trials: The need for vendor specific models to convert images to dose.

A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed using images from an electronic portal imaging device (EPID) on a Varian linear accelerator. It was tuned using beam profiles and field size factors (FSFs) of a series of square fields measured in water ta...

A multicenter dosimetry study to evaluate the imaging dose from Elekta XVI and Varian OBI kV-CBCT systems to cardiovascular implantable electronic devices (CIEDs).

The increasing use of daily CBCT in radiotherapy has raised concerns about the additional dose delivered to the patient, and it can also become a concern issue for those patients with cardiovascular implantable electronic devices (CIEDs) (Pacemaker [PM] and Implantable Cardioverter Defibrillator [ICD]). Although guidelines highly recommend that the cumulative dose received by CIEDs should be kept as low as possible, and a safe threshold based on patient risk classification needs to be respected, this additi...


A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience.

BACKGROUND The complex user interface design of radiotherapy treatment delivery systems can lead to use error and patient harm. In this study, we present the results of a comparison of 3 radiotherapy treatment delivery systems now used in China. MATERIAL AND METHODS We conducted a comprehensive usability study of 3 radiotherapy treatment delivery systems. Expert evaluation was performed through heuristic evaluation with 3 human-factors experts and 1 experienced radiation therapist for each system. User expe...

Low-Dose Gamma Knife Radiosurgery for Acromegaly.

Remission rate is associated with higher dose of Gamma Knife Radiosurgery (GKRS; Gamma Knife: Elekta AB, Stockholm, Sweden) for acromegaly, but the dose ≥25 Gy is not always feasible when the functioning adenoma is close to optic apparatus.

Comparison of intensity modulated radiotherapy plan optimisation methods for a 1.5 T MR-Linac.

For the 1.5 T Elekta MR-Linac it is essential that the optimisation of a treatment plan accounts for the electron return effect on the planned dose distribution. The ability of two algorithms for the first stage fluence optimisation, pencil beam (PB) and Monte Carlo (MC), to produce acceptable plan quality was investigated. Optimisation time for each algorithm was also compared.

Deep inspiration breath hold in breast cancer: Development and analysis of a patient experience questionnaire.

Evidence that Deep Inspiration Breath Hold (DIBH) can reduce cardiac dose during left-sided breast radiation therapy (RT) has led to widespread uptake of this technology. There is a paucity of published information documenting the impact of this technique on the patient's treatment experience. The aim of this study was to develop a tool to assess the patient's experience with the introduction of DIBH using the Elekta Active Breathing Coordinator (ABC) in a single institution.

Simultaneous optimization of isocenter locations and sector duration in radiosurgery.

Stereotactic radiosurgery is an effective technique to treat brain tumors for which several inverse planning methods may be appropriate. We propose an integer programming model to simultaneous sector duration and isocenter optimization (SDIO) problem for Leksell Gamma Knife{\textregistered} Icon{\texttrademark} (Elekta, Stockholm, Sweden) to tractably incorporate treatment time. We devise a Benders decomposition scheme to solve the SDIO problem to optimality. The performances of our approaches are assessed ...

Validation of secondary dose calculation system with manufacturer-provided reference beam data using heterogeneous phantoms.

The Mobius3D (M3D) system (Mobius Medical Systems) is a second-check dosimetry system. We investigated the dose calculation accuracy of this system using heterogeneous phantoms with reference beam data provided by the manufacturer using simple and patient plans. We compared the dose distributions between M3D and the treatment planning system, as well as the measurements in solid water phantoms, heterogeneous phantoms, and patient plans for Varian and Elekta accelerators. The M3D results agreed well with the...

10-MV SBRT FFF IRRADIATION TECHNIQUE IS ASSOCIATED TO THE LOWEST PERIPHERAL DOSE: THE OUTCOME OF 142 TREATMENT PLANS FOR THE 10 MOST COMMON TUMOUR LOCATIONS.

There is a growing interest in the combined use of Stereotactic Body Radiation Therapy (SBRT) with Flattening Filter Free (FFF) due to the high local control rates and reduced treatment times, compared to conventionally fractionated treatments. It has been suggested that they may also provide a better radiation protection to radiotherapy patients as a consequence of the expected decrease in peripheral doses. This work aims to determine this reduction in unattended out-of-field regions, where no CT informati...

Detection of the focal spot motion relative to the collimator axis of a linear accelerator under gantry rotation.

The potential for delivering high precision radiotherapy using linear accelerators (linacs) has been improved with the development of digital x-ray electronic portal imaging devices (EPID) for acquiring kilovoltage (kV) cone-beam CT and megavoltage (MV) images for patient positioning. EPIDs have also opened the possibilities of developing novel quality assurance and insight into radiotherapy equipment performance. The aim of this work was to measure the offset of the focal spot position (FSP) of a lina...

Second cancer risk after radiation therapy of ependymoma using the flattening filter free irradiation mode of a linear accelerator.

Pediatric patients suffering from ependymoma are usually treated with cranial or craniospinal three-dimensional (3D) conformal radiotherapy (3DCRT). Intensity-modulated techniques spare dose to the surrounding tissue, but the risk for second malignancies may be increased due to the increase in low-dose volume. The aim of this study is to investigate if the flattening filter free (FFF) mode allows reducing the risk for second malignancies compared to the mode with flattening filter (FF) for intensity-modulat...