Topics

PubMed Journals Articles About "Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement" RSS

14:03 EST 29th January 2020 | BioPortfolio

Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement PubMed articles on BioPortfolio. Our PubMed references draw on over 21 million records from the medical literature. Here you can see the latest Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement articles that have been published worldwide.

More Information about "Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement" on BioPortfolio

We have published hundreds of Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement news stories on BioPortfolio along with dozens of Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement Clinical Trials and PubMed Articles about Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement for you to read. In addition to the medical data, news and clinical trials, BioPortfolio also has a large collection of Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement Companies in our database. You can also find out about relevant Predictors Outcomes Stroke After Transcatheter Aortic Valve Replacement Drugs and Medications on this site too.

Showing "Predictors outcomes stroke after transcatheter aortic valve replacement" PubMed Articles 1–25 of 6,300+

Predictors and outcomes of stroke after transcatheter aortic valve replacement.

Stroke is a devastating complication of transcatheter aortic valve replacement (TAVR). Many studies have investigated risk factors for postoperative stroke, but reliable predictors are not yet well-established. The objective of this study was to further characterize the predictors and outcomes of stroke after TAVR.


Aortic valve calcification as a risk factor for major complications and reduced survival after transcatheter replacement.

Aortic valve calcification is supposed to be a possible cause of embolic stroke or subclinical valve thrombosis after transcatheter aortic valve replacement (TAVR). We aimed to assess the role of aortic valve calcification in the occurrence of in-hospital clinical complications and survival after TAVR.

Predictors and outcomes of patient-prosthesis mismatch after transcatheter aortic valve replacement.

Patient-prosthesis mismatch (PPM) has been shown to be associated with adverse outcomes after surgical aortic valve replacement. There is limited data on its risk and impact after transcatheter aortic valve replacement (TAVR), especially with the newer generation heart valves.


Health Status after Transcatheter vs. Surgical Aortic Valve Replacement in Low-Risk Patients with Aortic Stenosis.

In patients with severe aortic stenosis (AS) at low surgical risk, treatment with transcatheter aortic valve replacement (TAVR) results in lower rates of death, stroke, and re-hospitalization at 1 year compared with surgical aortic valve replacement; however, the effect of treatment strategy on health status is unknown.

Transcatheter Aortic Valve Replacement with the Lotus Valve: Concept and Current State of the Data.

Multiple transcatheter heart valve iterations have created an interesting range of options with which to perform transcatheter aortic valve replacement. The Lotus valve has several attractive features. The ability to eradicate even mild paravalvular leak mirrors the outcomes of surgical aortic valve replacement. New design iterations of the Lotus valve and refined sizing algorithms may help mitigate the need for permanent pacemaker implantation and consolidate its best-in-class results in terms of paravalvu...

Right Anterior Minithoracotomy for Endocarditis Following Transcatheter Aortic Valve Replacement.

Transcatheter aortic valve replacement becomes an equivalent alternative to surgical aortic valve replacement also in low-surgical-risk patients. Prosthetic valve endocarditis following transcatheter aortic valve replacement (TAVR-PVE) is a dangerous complication with the highest mortality rate among endocarditis patients. Only a minority of patients receives surgical treatment of TAVR-PVE. We present a case of surgical treatment of TAVR-PVE in a 75-years-old patient. The success of the treatment is based o...

Outcomes of Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis: A Review of a Disruptive Technology in Aortic Valve Surgery.

Medically treated symptomatic severe aortic stenosis has poor outcomes, and in the past 6 decades, it has successfully been treated with surgical aortic valve replacement (SAVR). However, one-third of patients with indications for SAVR are not offered surgery because of the high risk of complications. Transcatheter aortic valve replacement (TAVR), initially developed as a less invasive treatment for inoperable patients, has successfully been used in healthier patient cohorts. In 2017, TAVR became the most c...

Meta-Analysis of Transcatheter Aortic Valve Replacement in Low-Risk Patients.

To evaluate the efficacy and safety of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) in low surgical risk patients.

Flow, Reflected by Stroke Volume Index, Is a Risk Marker in High-Gradient Aortic Stenosis Patients Undergoing Transcatheter Aortic Valve Replacement.

Tools are needed to identify patients at increased risk after transcatheter aortic valve replacement (TAVR). Indexed stroke volume (SVi) is an echocardiographic measurement that is used for low-gradient aortic stenosis. We studied whether low SVi is a high-risk marker in patients with high-gradient aortic stenosis (HG-AS) and assessed the relationship between SVi and left ventricle (LV) systolic function in contributing to this risk.

Utility of 90-Day Mortality vs 30-Day Mortality as a Quality Metric for Transcatheter and Surgical Aortic Valve Replacement Outcomes.

Questions have recently arisen as to whether 30-day mortality is a reasonable metric for understanding institutional practice differences after transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR).

Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis.

Owing to new evidence from randomized controlled trials (RCTs) in low-risk patients with severe aortic stenosis, we compared the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the entire spectrum of surgical risk patients.

Pulsatile sterile abscess in the left breast following transapical transcatheter aortic valve implantation: a case report.

Over the last decade, transcatheter treatment of degenerative aortic valve stenosis has been established as an alternative to surgical aortic valve replacement. Late complications of transcatheter treatment of aortic stenosis (AS) are infrequent.

Immediate and Evolutionary Recovery of Left Ventricular Diastolic Function after Transcatheter Aortic Valve Replacement: Comparison with Surgery.

We aimed to compare the effect of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (sAVR) on recovery of left ventricular (LV) diastolic function and afterload through serial echocardiographic examinations in patients with symptomatic high-risk severe aortic stenosis during early follow-up.

Incomplete expansion of transcatheter aortic valves is associated with propensity for valve thrombosis.

Clinical and subclinical leaflet thromboses are increasingly recognized complications following transcatheter aortic valve replacement. Identification of the risk factors is important to mitigate the occurrence of leaflet thrombosis in transcatheter aortic valves (TAVs) and ensure their long-term function. The goal of this study was to determine the effect of incomplete expansion of TAVs on the likelihood of leaflet thrombosis following transcatheter aortic valve replacement.

Learning curve for transcatheter aortic valve replacement for native aortic regurgitation: Safety and technical performance study.

Transcatheter aortic valve replacement (TAVR) is a fundamentally new procedure for the treatment of native aortic regurgitation (AR). The number of cases needed to gain proficiency with the procedure is unknown.

Effect of Baseline Left Ventricular Ejection Fraction on 2-Year Outcomes After Transcatheter Aortic Valve Replacement: Analysis of the PARTNER 2 Trials.

Impaired left ventricular function is associated with worse prognosis among patients with aortic stenosis treated medically or with surgical aortic valve replacement. It is unclear whether reduced left ventricular ejection fraction (LVEF) is an independent predictor of adverse outcomes after transcatheter aortic valve replacement.

Valve-in-Ring Transcatheter Aortic Valve Replacement After Left Ventricular Assist Device Therapy.

Aortic regurgitation after left ventricular assist device (LVAD) implantation is a well-described problem that decreases the clinical effectiveness of LVAD therapy and may eventually prompt consideration of aortic valve replacement once the regurgitation becomes severe. Transcatheter aortic valve replacement (TAVR) is an attractive, less invasive option compared with surgical aortic valve replacement in these patients. We present the first case of a valve-in-ring TAVR for a patient with severe aortic regurg...

A Controlled Trial of Rivaroxaban after Transcatheter Aortic-Valve Replacement.

Whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear.

Mid-term outcome in patients with bicuspid aortic valve stenosis following transcatheter aortic valve replacement with a current generation device: A multicenter study.

To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve.

Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis in people with low surgical risk.

Severe aortic valve stenosis (AS) is a major cause of morbidity and mortality worldwide. The definitive management for severe AS is aortic valve replacement (AVR). The choice of transcatheter approach versus open-heart surgery for AVR in people with severe AS and low surgical risk remains a matter of debate.

Transcatheter aortic valve implantation versus surgical aortic valve replacement in patients at low and intermediate risk: A risk specific meta-analysis of randomized controlled trials.

Transcatheter aortic valve implantation (TAVI) is an option for treatment for patients with severe aortic stenosis who are at high risk for death with surgical aortic valve replacement (SAVR). It is unknown whether TAVI can be safely introduced to intermediate- and low-risk patients.

Computed tomography angiography is not accurate in predicting surgical prosthetic aortic valve implant size.

Multidetector computed tomography is vital in preoperative sizing for transcatheter aortic valve replacement. The purpose of this study is to determine whether preoperative transcatheter aortic valve replacement multidetector computed tomography accurately predicts surgical aortic valve prosthesis size.

Impact of Repositioning During Transcatheter Aortic Valve Replacement on Embolized Debris.

Use of the dual-filter cerebral embolic protection (CEP) device has been linked to a lower stroke rate in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Captured debris is found in almost every filter. The impact of repositioning on number and area of captured debris has not been studied.

Transcatheter vs surgical aortic valve replacement in patients with interstitial lung disease.

Patients with underlying interstitial lung disease (ILD) who undergo cardiac surgery are at high risk of postoperative pulmonary complications. It remains unclear if transcatheter aortic valve replacement (TAVR) offers any benefit over surgical aortic valve replacement (SAVR) in ILD patients with severe aortic stenosis.

Chronic type A aortic dissection after transcatheter aortic valve replacement.

An 87-year-old man with hostile ascending aorta who underwent transfemoral transcatheter aortic valve replacement (TAVR) using 26-mm Sapien 3 (Edwards Lifesciences, Irvine, CA, USA) 2 years ago, presented with chronic type A aortic dissection, which was retrospectively caused by the edge of the pusher of the TAVR implantation system. Redo sternotomy, extraction of Sapien valve followed replacement of ascending aorta and aortic valve was done successfully. Retrospective image analysis showed importance of re...


Quick Search