Advertisement

Topics

PubMed Journals Articles About "Ceramic Crowns Tooth Wear" RSS

06:02 EST 14th December 2018 | BioPortfolio

Ceramic Crowns Tooth Wear PubMed articles on BioPortfolio. Our PubMed references draw on over 21 million records from the medical literature. Here you can see the latest Ceramic Crowns Tooth Wear articles that have been published worldwide.

More Information about "Ceramic Crowns Tooth Wear" on BioPortfolio

We have published hundreds of Ceramic Crowns Tooth Wear news stories on BioPortfolio along with dozens of Ceramic Crowns Tooth Wear Clinical Trials and PubMed Articles about Ceramic Crowns Tooth Wear for you to read. In addition to the medical data, news and clinical trials, BioPortfolio also has a large collection of Ceramic Crowns Tooth Wear Companies in our database. You can also find out about relevant Ceramic Crowns Tooth Wear Drugs and Medications on this site too.

Showing "ceramic crowns Tooth Wear" PubMed Articles 1–25 of 848

Incisor tooth wear and age determination in mountain gorillas from Volcanoes National Park, Rwanda.

Ecological factors, but also tooth-to-tooth contact over time, have a dramatic effect on tooth wear in primates. The aim of this study is to test whether incisor tooth wear changes predictably with age and can thus be used as an age estimation method in a wild population of mountain gorillas (Gorilla beringei beringei) from Volcanoes National Park, Rwanda.


Effect of Simulated Mastication on the Surface Roughness and Wear of Machinable Ceramics and Opposing Dental Enamel.

Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface roughness and wear, the three-body wear simulation was investigated.

Impact of tooth wear on masticatory performance.

Masticatory performance is influenced by a number of variables such as age, gender, bite force, and occlusal units. Tooth wear may also play a role due to changes in occlusal area and in vertical dimension of occlusion. The aim of this study was to evaluate the effect of tooth wear on masticatory performance, using a communition test.


In Vitro Fatigue and Fracture Testing of Implant-Supported Anterior Ceramic Crowns.

To evaluate the fatigue and fracture resistance of anterior implant-supported and tooth-supported crowns made of different monolithic ceramics.

Erosive Tooth Wear and Dietary Patterns: A Clinical Study.

Evidence exists which suggests that a vegetarian diet is a predisposing factor to erosive tooth wear. The aim of this study was to assess the influence of dietary pattern (vegetarian, lacto-ovo vegetarian and omnivore) on erosive tooth wear.

Influence of microscale expansion and contraction caused by thermal and mechanical fatigue on retentive strength of CAD/CAM-generated resin-based composite crowns.

CAD/CAM-generated resin-based composite crowns have been proposed as an inexpensive alternative to conventional crowns. However, concerns have been raised about crown loosening in clinical use. Therefore, the present in vitro study aimed to evaluate the influence of thermal and mechanical cycling (TC and MC) on retentive strength of CAD/CAM resin-based crowns in relation to microscale expansion and contraction caused by fatigue. Eighty standardized dies were produced using a resin-based composite material. ...

Reasoning of adhesive system choice for treatment of patients with increased tooth wear.

Introduction: Perceiving the high prevalence of direct composite restoration technique usage for the rehabilitation of patients with increased tooth wear, as well as during the sanitation of oral cavity before indirect methods of rehabilitation, there is a necessity in more detailed reasoning of adhesive system application for treatment of dentition with increased tooth wear. The aim: The purpose of our work was to study the microstructure and chemical compound of hard tissues of teeth on background of incr...

Recent advances in understanding the fatigue and wear behavior of dental composites and ceramics.

Dental composite and ceramic restorative materials are designed to closely mimic the aesthetics and function of natural tooth tissue, and their longevity in the oral environment depends to a large degree on their fatigue and wear properties. The purpose of this review is to highlight some recent advances in our understanding of fatigue and wear mechanisms, and how they contribute to restoration failures in the complex oral environment. Overall, fatigue and wear processes are found to be closely related, wit...

Wear at the taper-trunnion junction of contemporary ceramic-on-ceramic hips shown in a multistation hip simulator.

Ceramic-on-ceramic (CoC) total hip replacements (THR) have a substantially lower wear rate than metal-on-polyethylene (MoP) hips, as shown by hip simulator testing. However, the revision rates of CoC and MoP hips are comparable. To try and explain this discrepancy the wear, at both the bearing surfaces and taper-trunnion interface of 36 mm BIOLOXdelta CoC THRs, mounted on 12/14 titanium (Ti6Al4V) trunnions was investigated using a hip simulator (n = 3) and a dynamically loaded CoC sample in a separate test ...

Genome-Wide Association Study of Erosive Tooth Wear in a Finnish Cohort.

Erosive tooth wear is defined as irreversible loss of dental tissues due to intrinsic or extrinsic acids, exacerbated by mechanical forces. Recent studies have suggested a higher prevalence of erosive tooth wear in males, as well as a genetic contribution to susceptibility to erosive tooth wear. Our aim was to examine erosive tooth wear by performing a genome-wide association study (GWAS) in a sample of the Northern Finland Birth Cohort 1966 (n = 1,962). Erosive tooth wear was assessed clinically using the ...

Prevalence, severity and explanatory factors of tooth wear in Arab populations.

The aim of this study was to assess the prevalence and severity of tooth wear and related risk indicators in six Arab countries.

The Effect of Adhesive Failure and Defects on the Stress Distribution in All-ceramic Crowns.

To explore the effect of adhesive failure and defects between the crown and cement on the stress distribution within all-ceramic crowns and the corresponding risk of failure.

Assessment of Antagonist Enamel Wear and Clinical Performance of Full-Contour Monolithic Zirconia Crowns: One-Year Results of a Prospective Study.

To assess the clinical performance and survival of full-contour monolithic zirconia (MZ) crowns and enamel wear produced over a 1-year period.

Oral health-related impact profile in full-mouth restored patients with two different tooth-colored restoration materials.

To analyze the change of oral health impact profile (OHIP) in patients with full-mouth rehabilitations due to moderate/severe tooth wear dependent on different restorative materials (ceramic/experimental CAD/CAM composite).

Tooth wear during orthodontic treatment with fixed appliances: a systematic review.

Tooth wear, additional to the physiologic alterations of the dentition, may occur during orthodontic treatment. The objective of the present review was to investigate systematically the literature relevant to its progression in patients having undergone comprehensive orthodontic treatment.

Comparative study of the wear of the pair human teeth/Vita Enamic® vs commonly used dental ceramics through chewing simulation.

Ceramic based prosthetic materials have been used in dental restorations due to their excellent aesthetic and biocompatibility. However, due to concerns related to their mechanical properties and abrasive action against natural teeth, a proper selection of these materials is crucial to preserve the occlusal interactions and prevent abnormal dental wear. The aim of this work is to compare the wear performance of Vita Enamic®, a polymer infiltrated ceramic (PIC), with that of other three commercial ceramic b...

Erosive tooth wear: knowledge among young adults and their preferred information sources.

The aim of this study was to learn more about levels of knowledge relating to erosive tooth wear and about the most desirable way of disseminating dental information among young adults.

Toothbrush Wear in Relation to Tooth Brushing Effectiveness.

To investigate to what extent the degree of toothbrush wear of 3-month-old manual toothbrushes influence plaque scores.

Effect of cavity preparation design and ceramic type on the stress distribution, strain and fracture resistance of CAD/CAM onlays in molars.

Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from l...

Ultra-thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load-bearing capacities not different from conventional restorations.

The objective of this study was to test whether or not the load-bearing capacity of occlusal veneers bonded to enamel and made of ceramic or hybrid materials does differ from those of porcelain-fused-to-metal or lithium disilicate glass ceramic crowns.

Fracture Resistance of Computer-Aided Design/Computer-Assisted Manufactured Glass-Ceramic Incisor Crowns Fabricated on Reverse-Tapered Preparations.

To evaluate the fracture resistance of computer-aided design/computer-assisted manufactured (CAD/CAM) glass-ceramic incisor crowns fabricated on reverse-tapered preparations.

Bearing capacity of ceramic crowns before and after cyclic loading: An in vitro study.

The objective of this study was to compare the resistance to failure of three types of all-ceramic crowns under static and cyclic contact loading. Three types of crown specimens were fabricated (N = 14 per group) including: i) sintered bi-layer crowns (SBC) made of IPS e.max CAD veneers fused on Lava zirconia core ceramics, ii) adhesive bi-layer crowns (ABC) made of IPS e.max CAD veneers bonded onto Lava zirconia core ceramics, and iii) monolith ceramics crown (MCC) made of IPS e.max CAD. All were bonde...

Fracture resistance of all-ceramic crowns based on different preparation designs for restoring endodontically treated molars.

To evaluate endodontically treated molar fracture resistance restored with CAD/CAM lithium disilicate (LDS) crowns with different amalgam core preparation design.

Retentive force of PEEK secondary crowns on zirconia primary crowns over time.

The purpose of the present study was to evaluate the retentive forces of CAD/CAM-fabricated polyetheretherketone (PEEK) secondary crowns on zirconia primary crowns over an artificial aging period representing 10 years of clinical service and compare them to electroformed secondary crowns made from pure gold.

Immediate loading at single crowns and 2-unit bridges supported by implants installed in a healed alveolar bony ridge or immediately after tooth extraction. An experimental study in dogs.

to evaluate presumptive differences in osseointegration at implants installed in healed sites or extraction sockets, supporting either crowns or bridges that were functionally loaded or left unloaded.


Advertisement
Quick Search
Advertisement
Advertisement