Topics

AL-2 MP-1 (Polyimide) Acetabular Liner

2015-07-22 11:38:23 | BioPortfolio

Summary

M.M.A.TECH Ltd. product is an Acetabular Liner Family produced of an advanced polyimide - MP-1™.

M.M.A.TECH Ltd. produces the Liners according to EN ISO 13485:2012 approved manufacturing process and supplies them to the customer.

The aim of this study is to evaluate, in the frame of PMCF, the safety and performance of using AL-X MP1 Polyimide Acetabular liners in Total Hip Replacement surgery by clinical following up of patients for a period of 2 years .

Description

The procedure involves removal of the diseased parts of the joint, that is the damaged cartilage and adjacent bone, and replacing them with artificial parts which closely resemble in structure and/or function the removed native parts.

The artificial parts fit onto the reshaped bone and are fixed either with bone cement (e.g., polymethylmethacrylate) and press fit of the part(cemented), or by self-anchorage with bone ingrowth to its porous surface(cementless).

The design of the artificial parts may include a stem, a keel or pegs, which fit onto the medullary canal of the bone or into a hole pre-prepared in the bone. An artificial part may fit loosely and be fixed with bone cement, press-fit for self- anchorage or include extendible anchors which are retracted upon placement and extended thereafter so as to secure the implant in place.

Following fixation of the components, the joint is reduced and the soft tissue tension is appropriately checked to reassure stability of the joint.

The MP-1™ acetabular liner will be tapper locked in acetabular metal shells to resurface the acetabular socket in cementless total hip replacement.

MMaTech Ltd will manufacture the liners to perfectly fit into the external metallic shell of the following sizes (mm):

LINER CUP SIZE LINER SIZE HEAD Liner thickness AL-2MP132040 44-48 32 ID 40 OD 32 4 mm AL-2MP136044 50-54 36 ID 44 OD 36 4mm AL-2MP136048 56-66 36 ID 48 OD 36 6mm AL-2MP140048 56-66 40 ID 48 OD 40 4mm

The MP-1™ Acteabular liners are intended to be used only against ceramic femoral heads- Biolox Delta

Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment

Conditions

Osteoarthritis

Intervention

MP-1 Polymer on Ceramic Articulation system

Status

Not yet recruiting

Source

M.M.A Tech Ltd.

Results (where available)

View Results

Links

Published on BioPortfolio: 2015-07-22T11:38:23-0400

Clinical Trials [1399 Associated Clinical Trials listed on BioPortfolio]

A Multicentre Trial to Compare Two Articulating Bearing Surfaces as Used in Cementless Primary Hip Arthroplasty

The aim of this study is to demonstrate the non-inferiority of the ceramic-on-metal articulation using large diameter bearings (38mm to 60mm) compared to the metal on metal articulation us...

Post Approval Study: NOVATION Ceramic Articulation Hip System

The purpose of this study is to collect and evaluate long-term safety and effectiveness data on the Exactech® NOVATION ™ Ceramic Articulation Hip System ("NOVATION ™ Ceramic AHS"). Ten ...

Continuum Ceramic on Ceramic Bearing PMCF Study

The primary objective of this study is to obtain implant survivorship and clinical outcome data for the commercially available Zimmer® Continuum™ Ceramic-on-Ceramic Bearing System when ...

Ceramic-on-ceramic THA for Post-traumatic Hip Osteoarthritis After Acetabular Fracture

A retrospective consecutive population of patients treated with cementless total hip arthroplasty with ceramic-on-ceramic bearing surfaces due to post-traumatic osteoarthritis due to aceta...

Ceramic-on-Ceramic Versus Ceramic-on-HXLPE THA

Methods to reduce the revision rate of total hip arthroplasties (THAs) because of wear-related issues are important to examine, particularly because younger patients have a disproportionat...

PubMed Articles [10581 Associated PubMed Articles listed on BioPortfolio]

Nacre-Inspired Composite Electrolytes for Load-Bearing Solid-State Lithium-Metal Batteries.

Solid-state lithium-metal batteries with solid electrolytes are promising for next-generation energy-storage devices. However, it remains challenging to develop solid electrolytes that are both mechan...

Biofilm Formation and Cell Viability on Polymer-infiltrated Ceramic and Yttria-stabilized Polycrystalline Zirconium Dioxide Ceramic.

The aim of this study was to investigate the biofilm formation and cell viability of a polymer-infiltrated ceramic (PIC) and an yttria-stabilized polycrystalline zirconium dioxide ceramic (Y-TZP). The...

Magnetic Resonance Imaging Findings Following Ceramic-on-Ceramic Total Hip Arthroplasty Using Modular Neck Femoral Components.

Adverse reactions to metal debris after total hip arthroplasty are an increasing concern. Metal debris is released from the metal-on-metal articulation itself as well as from the head-neck taper. Ther...

Articulation of an alumina-zirconia composite ceramic against living cartilage - An in vitro wear test.

There is interest in minimally invasive solutions that reduce osteoarthritic symptoms and restore joint mobility in the early stages of cartilage degeneration. The aim of the present study was to eval...

Magnetically Actuated SiCN-Based Ceramic Microrobot for Guided Cell Delivery.

A silicon carbonitride (SICN) ceramic microrobot, biocompatible and magnetically activable, is developed for the delivery of viable cells to defective tissue by sequential steps of microstructuring, m...

Medical and Biotech [MESH] Definitions

Tests of accuracy in pronouncing speech sounds, e.g., Iowa Pressure Articulation Test, Deep Test of Articulation, Templin-Darley Tests of Articulation, Goldman-Fristoe Test of Articulation, Screening Speech Articulation Test, Arizona Articulation Proficiency Scale.

Strongly cationic polymer that binds to certain proteins; used as a marker in immunology, to precipitate and purify enzymes and lipids. Synonyms: aziridine polymer; Epamine; Epomine; ethylenimine polymer; Montrek; PEI; Polymin(e).

A type of porcelain used in dental restorations, either jacket crowns or inlays, artificial teeth, or metal-ceramic crowns. It is essentially a mixture of particles of feldspar and quartz, the feldspar melting first and providing a glass matrix for the quartz. Dental porcelain is produced by mixing ceramic powder (a mixture of quartz, kaolin, pigments, opacifiers, a suitable flux, and other substances) with distilled water. (From Jablonski's Dictionary of Dentistry, 1992)

A polymer obtained by reacting polyacrylic acid with a special anion-leachable glass (alumino-silicate). The resulting cement is more durable and tougher than others in that the materials comprising the polymer backbone do not leach out.

A polyester used for absorbable sutures & surgical mesh, especially in ophthalmic surgery. 2-Hydroxy-propanoic acid polymer with polymerized hydroxyacetic acid, which forms 3,6-dimethyl-1,4-dioxane-dione polymer with 1,4-dioxane-2,5-dione copolymer of molecular weight about 80,000 daltons.

More From BioPortfolio on "AL-2 MP-1 (Polyimide) Acetabular Liner"

Quick Search

Relevant Topics

Joint Disorders
A joint is where two or more bones come together, like the knee, hip, elbow, or shoulder. Joints can be damaged by many types of injuries or diseases, including Arthritis - inflammation of a joint causes pain, stiffness, and swelling with ...

Surgical treatments
Surgery is a technology consisting of a physical intervention on tissues. All forms of surgery are considered invasive procedures; so-called "noninvasive surgery" usually refers to an excision that does not penetrate the structure being exci...

Rheumatology
Arthritis Fibromyalgia Gout Lupus Rheumatic Rheumatology is the medical specialty concerned with the diagnosis and management of disease involving joints, tendons, muscles, ligaments and associated structures (Oxford Medical Diction...


Searches Linking to this Trial