Cardiorespiratory Effects of "Higher" Versus "Equivalent" CPAP Upon Extubation From High EAP in Preterm Infants

2015-08-19 20:23:23 | BioPortfolio

Summary

The aim of this study is to compare the cardiovascular and respiratory effects of "higher" versus "equivalent" CPAP pressures post-extubation from high endotracheal airway pressures (EAP), defined as at least 8 cm H2O (water), in the form of a randomized controlled cross-over trial. Endotracheal airway pressure (EAP) will be defined as mean airway pressure (MAP) [if on high frequency ventilation] or positive end-expiratory pressure (PEEP) [if on conventional ventilation] at time of extubation. Participants will be randomized to "higher" CPAP group (CPAP level 2cm H2O higher than the extubation EAP) or "equivalent" CPAP group (CPAP level equal to the extubation EAP) before undergoing crossover to the other arm. We hypothesize that "higher" CPAP levels, when compared to "equivalent" CPAP levels, do not adversely impact the cardiorespiratory status when a patient is extubated from high EAP.

Description

Extubation readiness of the enrolled infants will be determined solely by and at the discretion of the medical team. All enrolled infants will be checked to re-confirm eligibility prior to extubation. Those enrolled infants who are ventilated on EMV (endotracheal mechanical ventilation) with an airway pressure of 8-11 cm H2O at the time when they are deemed extubation-ready by the team will be eligible for randomization. Once eligibility for randomization is assessed, the study coordinator will notify the research team who will immediately perform a bedside functional echocardiography to assess cardiac output and PDA (patent ductus arteriosus) status. In addition, the lung compliance (as measured by the ventilator) will be recorded. If a PDA exists and is found to be hemodynamically significant, then the infant meets one of the exclusion criteria and will be ineligible for randomization.

Once eligibility is confirmed, infants will be randomized using sequentially numbered sealed opaque envelopes. The sequence of the randomization will be pre-determined using a computer generated algorithm, and sealed envelopes will be created by study coordinator. Once randomized, the infants will be extubated to the "higher" CPAP group (CPAP level 2cm H2O higher than extubation EAP) or "equivalent" CPAP group (CPAP level equal to the extubation EAP) based on their allocation.

After ensuring that the infants are stable for one hour (based on pre-defined clinical instability criteria) cardiac output will be measured using bedside functional echocardiography by members of the research team blinded to the allocation. To ensure blinding the research coordinator will cover the relevant digital display of the ventilator/CPAP machine (with opaque craft paper and tape) immediately prior to the echocardiography. Other aforementioned outcomes will be recorded by the blinded investigator using standardized data collection forms. Once all outcome data are collected, the infants will cross-over to the opposite arm of the trial and a similar assessment protocol will be followed after one hour. The study protocol will be considered completed when the second set of measurements is obtained and further respiratory management will be guided by the medical team.

SAFETY ASSURANCE At any point during the study, emergence of any one of the clinical instability criteria will prompt the nursing staff to notify the medical team who would immediately assess the infant. If the infant shows signs of clinical instability the medical team will evaluate the infants' clinical condition as per a pre-defined checklist. When all the troubleshooting points mentioned in the checklist are addressed by the medical team and the infant is deemed clinically unstable, the infant would be immediately removed from the study protocol and parents of the subject will be notified. To ensure that no other factor affects the hemodynamic status of the infants during the study, the total fluid intake would remain the same and no caffeine citrate would be administered during the period of pre and post extubation assessment of cardiac output.

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Crossover Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment

Conditions

Preterm Infant

Intervention

Extubation from endotracheal mechanical ventilation to CPAP

Status

Not yet recruiting

Source

McMaster University

Results (where available)

View Results

Links

Published on BioPortfolio: 2015-08-19T20:23:23-0400

Clinical Trials [2573 Associated Clinical Trials listed on BioPortfolio]

Comparison of NIV-NAVA vs. N-CPAP After Extubation in Preterm Infants Study

This study is a randomized controlled study to compare if a a non-invasive neurally adjusted ventilatory assist (NIV-NAVA) is better than nasal continuous positive airway pressure (N-CPAP)...

Surfactant Via Endotracheal Tube vs. Laryngeal Mask Airway (LMA) in Preterm Neonates With Respiratory Distress Syndrome

In this study, newborn babies with respiratory distress syndrome (RDS), receiving oxygen via nasal continuous airway pressure (CPAP) modalities, and needing surfactant treatment will be ra...

Cpap at Delivery Room for Preterm Infants

The objective of the study is to determine if CPAP applied within less than 15 min of life in the DR reduces the necessity of mechanical ventilation and surfactant during the first 5 days ...

NIPPV Versus Bi-level Nasal Continuous Positive Airway Pressure Following Extubation

Mechanical ventilation is important in the care of preterm infants with respiratory failure, but may be associated with lung injury. Efforts are needed to avoid or minimize the use of mech...

Randomized Controlled Trial of Surfactant Delivery Via Laryngeal Mask Airway (LMA) Versus Endotracheal Intubation

In this study, newborn babies with respiratory distress syndrome (RDS), receiving oxygen via nasal CPAP, and needing surfactant treatment will be randomized to standard delivery of surfact...

PubMed Articles [4743 Associated PubMed Articles listed on BioPortfolio]

Predictive factors of weaning from mechanical ventilation and extubation outcome: A systematic review.

To identify, describe and discuss the parameters used to predict weaning from mechanical ventilation and extubation outcomes.

Evidence-based clinical guidelines on analgesia and sedation in newborn infants undergoing assisted ventilation and endotracheal intubation.

This review informed pain control guidelines for clinicians performing mechanical ventilation, nasal continuous positive airway pressure and endotracheal intubation on term and preterm newborn infants...

Home Extubation in a Neonate.

End-of-life care for many infants involves the withdrawal of mechanical ventilation. Usually this takes place in the hospital environment, but sometimes parents request that their infant dies at home....

Effect of Protocolized Weaning With Early Extubation to Noninvasive Ventilation vs Invasive Weaning on Time to Liberation From Mechanical Ventilation Among Patients With Respiratory Failure: The Breathe Randomized Clinical Trial.

In adults in whom weaning from invasive mechanical ventilation is difficult, noninvasive ventilation may facilitate early liberation, but there is uncertainty about its effectiveness in a general inte...

Nasal High-flow During Neonatal and Infant Transport In Victoria, Australia.

The Paediatric Infant and Perinatal Emergency Retrieval (PIPER) service based in Melbourne, Victoria performs approximately 2800 transfers of neonates and young infants annually, of which >1100 are em...

Medical and Biotech [MESH] Definitions

Removal of an endotracheal tube from the patient.

A chronic lung disease developed after OXYGEN INHALATION THERAPY or mechanical ventilation (VENTILATION, MECHANICAL) usually occurring in certain premature infants (INFANT, PREMATURE) or newborn infants with respiratory distress syndrome (RESPIRATORY DISTRESS SYNDROME, NEWBORN). Histologically, it is characterized by the unusual abnormalities of the bronchioles, such as METAPLASIA, decrease in alveolar number, and formation of CYSTS.

Techniques for effecting the transition of the respiratory-failure patient from mechanical ventilation to spontaneous ventilation, while meeting the criteria that tidal volume be above a given threshold (greater than 5 ml/kg), respiratory frequency be below a given count (less than 30 breaths/min), and oxygen partial pressure be above a given threshold (PaO2 greater than 50mm Hg). Weaning studies focus on finding methods to monitor and predict the outcome of mechanical ventilator weaning as well as finding ventilatory support techniques which will facilitate successful weaning. Present methods include intermittent mandatory ventilation, intermittent positive pressure ventilation, and mandatory minute volume ventilation.

Mechanical devices used to produce or assist pulmonary ventilation.

Mechanical ventilation delivered to match the patient's efforts in breathing as detected by the interactive ventilation device.

More From BioPortfolio on "Cardiorespiratory Effects of "Higher" Versus "Equivalent" CPAP Upon Extubation From High EAP in Preterm Infants"

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topics

Cardiovascular disease (CVD)
Acute Coronary Syndromes (ACS) Blood Cardiovascular Dialysis Hypertension Stent Stroke Vascular Cardiovascular disease (CVD) includes all the diseases of the heart and circulation including coronary heart disease (angina...

Respiratory
Asthma COPD Cystic Fibrosis Pneumonia Pulmonary Medicine Respiratory Respiratory tract infections (RTIs) are any infection of the sinuses, throat, airways or lungs.  They're usually caused by viruses, but they can also ...


Searches Linking to this Trial