A 24-month Clinical Evaluation of Different Bulk-fill Restorative Resins in Class II Restorations

2018-05-22 18:49:10 | BioPortfolio

Published on BioPortfolio: 2018-05-22T18:49:10-0400

Clinical Trials [169 Associated Clinical Trials listed on BioPortfolio]

Evaluation of Marginal Integrity of Hydroxyapatite Nano-Fiber Reinforced Flowable Composite Versus Conventional Resin-Based Flowable Composite in Initially Demineralized Pits and Fissure: A One Year, Randomized Clinical Trial

This study will be conducted to evaluate the Marginal integrity of Hydroxyapatite Nanofiber reinforced flowable composite compared to a conventional resin-based flowable composite during m...

Retention Rate of Hydroxyapatite Nano-Fiber Reinforced Flowable Composite Versus Conventional

Pits and fissures have been considered as the single most important feature leading to the development of occlusal caries; About 90 % of carious lesions are found in the pits and fissures ...

Stainless Steel Crowns Versus Bulkfill Composite Resin for Restoring Primary Molars After Endodontic Treatment

The pulp therapy in primary teeth is designed to eliminate the infection and keep the tooth in a functional state until its natural exfoliation. An important step for the success of endodo...

Long Term Clinical Evaluation of a Posterior Glass Hybrid System vs. Composite Resin

The primary objective of this study is to evaluate long-term clinical performance of a glass hybrid restorative system (glass-ionomer) vs. composite resin material over a period of five ye...

VergenixTM Flowable Gel in Patients With Lower Limb Ulcers

Vergenix Flowable Gel is indicated for the management of acute and chronic wounds

PubMed Articles [1282 Associated PubMed Articles listed on BioPortfolio]

Determination of polymerization shrinkage of different composites using a photoelastic method.

To investigate the polymerization shrinkage stress of different low viscous bulk composites (SDR, Venus Bulk Fill, X-tra Base, Filtek Bulk Fill) in comparison to a conventional flowable composite (Fil...

Influence of Polishing System on the Surface Roughness of Flowable and Regular-Viscosity Bulk Fill Composites.

This study evaluated the influence of polishing protocols on the surface roughness of flowable and regular bulk fill composites. Five bulk fill composites were tested: SureFil SDR Flow (SDR), Tetric E...

Cuspal Deflection in Premolar Teeth Restored with Bulk-Fill Resin-Based Composite Materials.

The present study investigated the effect of three high-viscosity bulk-fill resin-based composite materials on cuspal deflection in natural teeth. Thirty-two sound maxillary premolar teeth with large ...

Bond strength values of fiberglass post to flared root canals reinforced with different materials.

The aim of this study was to compare in vitro the bond strength (BS) between fiberglass posts and flared root canals reinforced with different materials. The roots of 48 premolars were endodontically ...

Porosity of flowable resin composites is not influenced by applicator tip diameter.

To assess the influence of applicator tip diameter on the inclusion of porosities in three different flowable resin composites.

Medical and Biotech [MESH] Definitions

A TEXTILE fiber obtained from the pappus (outside the SEEDS) of cotton plant (GOSSYPIUM). Inhalation of cotton fiber dust over a prolonged period can result in BYSSINOSIS.

Techniques using laser energy in combination with a balloon catheter to perform angioplasty. These procedures can take several forms including: 1, laser fiber delivering the energy while the inflated balloon centers the fiber and occludes the blood flow; 2, balloon angioplasty immediately following laser angioplasty; or 3, laser energy transmitted through angioplasty balloons that contain an internal fiber.

Disorder of the peripheral nerves that primarily impair small nerve fibers. The affected small nerve fibers include myelinated A-delta fibers (see A FIBERS) and unmyelinated C FIBERS. Because these small fibers innervate skin and help control autonomic function, their neuropathy presents with neuropathic pain, reduced thermal and pain sensitivity, and autonomic dysfunction (e.g. abnormal sweating or facial flushing). Small fiber neuropathy can be idiopathic or associated with underlying diseases (e.g., AMYLOIDOSIS; DIABETES MELLITUS; SARCOIDOSIS; or VASCULITIS).

A class of nerve fibers as defined by their structure, specifically the nerve sheath arrangement. The AXONS of the unmyelinated nerve fibers are small. The axons to SCHWANN CELLS ratio is greater in the unmyelinated nerve fibers than that in the myelinated fiber (NERVE FIBERS, MYELINATED) which is 1:1. Usually several axons are surrounded by a single Schwann cell in the unmyelinated nerve fibers. Therefore, each unmyelinated fiber is not completely covered by the MYELIN SHEATH formed by the Schwann cell. Unmyelinated nerve fibers conduct impulses at low velocities. They represent the majority of peripheral sensory and autonomic fibers. They are also found in the spinal cord and brain.

A continuous protein fiber consisting primarily of FIBROINS. It is synthesized by a variety of INSECTS and ARACHNIDS.

More From BioPortfolio on "A 24-month Clinical Evaluation of Different Bulk-fill Restorative Resins in Class II Restorations"