Advertisement

Topics

Sort Out XI - Combo Stent Versus BioMatrix Alpha Stent

2019-05-21 20:22:19 | BioPortfolio

Published on BioPortfolio: 2019-05-21T20:22:19-0400

Clinical Trials [2773 Associated Clinical Trials listed on BioPortfolio]

To Evaluate Safety and Efficacy of CGBIO Stent Compared to Biomatrix Flex Stent in Patients Undergoing Drug-eluting Stent Procedure After Coronary Angiography

to evaluate safety and efficacy of CGBIO stent(DES) compared to Biomatrix flex stent(DES)

HARMONEE - Japan-USA Harmonized Assessment by Randomized, Multi-Center Study of OrbusNEich's Combo StEnt

This is a multi-center, single-blind, randomized, active-controlled, clinical trial in Percutaneous Coronary Intervention [PCI] subjects. Subjects will be randomized to receive the Combo s...

LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating

The purpose of this study is to compare the safety and efficacy of the BioMatrix Flex (Biolimus A9-Eluting) stent system with the Cypher SELECT (Sirolimus-Eluting) stent system in a prospe...

Safety and Effectiveness Study of Combo Bio-engineered Sirolimus Eluting Stent

To demonstrate the safety and effectiveness of the Combo Bio-engineered Sirolimus Eluting Stent (Combo Stent) compared to the Taxus® Liberté® Stent in the treatment of coronary artery l...

SORT OUT X - Combo Stent Versus ORSIRO Stent

The aim of the Danish Organisation for randomised trials with clinical outcome (SORT OUT) is to compare the safety and efficacy of the ComboTM stent and Orsiro™ stent in the treatment of ...

PubMed Articles [3580 Associated PubMed Articles listed on BioPortfolio]

Safety and efficacy of the COMBO bio-engineered stent in an all-comer PCI cohort: 1-Year final clinical outcomes from the MASCOT post-marketing registry.

The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained rele...

Repeat stent implementation for recanalization of the proximal right coronary artery: a case report.

A stent in a false lumen is a common cause of stent occlusion after coronary percutaneous coronary artery intervention therapy, particularly in the culprit lesion of acute myocardial infarction. Here,...

Multi-Objective Optimization Design of Balloon-Expandable Coronary Stent.

Recent studies suggested that suboptimal delivery and longitudinal stent deformation can result in in-stent restenosis. Therefore, the purpose of this paper was to study the effect of stent geometry o...

Coronary Stent Fracture: Clinical Evidence Vs. the Testing Paradigm.

The United States' Food and Drug Administration (FDA) recommends that device manufacturers demonstrate 10 years of equivalent life duration for endovascular stents. Yet since the early 2000s clinical ...

The Pt-Cr everolimus-eluting stent with bioabsorbable polymer in the treatment of patients with acute coronary syndromes. Results from the SYNERGY ACS registry.

We investigated the safety and efficacy of the bioabsorbable polymer-coated, everolimus-eluting coronary stent (SYNERGY) stent in a real-world study population with acute coronary syndromes (ACS).

Medical and Biotech [MESH] Definitions

The new and thickened layer of scar tissue that forms on a PROSTHESIS, or as a result of vessel injury especially following ANGIOPLASTY or stent placement.

Surgical construction of an artificial opening (stoma) for external fistulization of a duct or vessel by insertion of a tube with or without a supportive stent.

Postoperative hemorrhage from an endovascular AORTIC ANEURYSM repaired with endoluminal placement of stent grafts (BLOOD VESSEL PROSTHESIS IMPLANTATION). It is associated with pressurization, expansion, and eventual rupture of the aneurysm.

Abnormal balloon- or sac-like dilatation in the wall of CORONARY VESSELS. Most coronary aneurysms are due to CORONARY ATHEROSCLEROSIS, and the rest are due to inflammatory diseases, such as KAWASAKI DISEASE.

Malformations of CORONARY VESSELS, either arteries or veins. Included are anomalous origins of coronary arteries; ARTERIOVENOUS FISTULA; CORONARY ANEURYSM; MYOCARDIAL BRIDGING; and others.

More From BioPortfolio on "Sort Out XI - Combo Stent Versus BioMatrix Alpha Stent"

Advertisement
Quick Search
Advertisement
Advertisement

 

Searches Linking to this Trial