Summary

In this prospective, randomised, controlled, unblinded,monocentric study, we aim to evaluate the safety and efficacy of higher power CLOSE-guided PVI in patients referred for a first ablation for paroxysmal AF. We aim to include 100 patients into two groups (1:1). The experimental group will receive AF ablation with 45 Watt and stricter stability criteria (3 mm for 3 seconds) compared to the control group which will receive AF ablation according to the standard CLOSE-protocol (35 Watt and stability criteria of 3 mm for 8 seconds).

Description

BACKGROUND: In a population of paroxysmal AF 'CLOSE'-guided PVI (Target Ablation index (AI) >550 and >400 for anterior and posterior wall respectively, interlesion distance ≤6mm) has been shown to obtain single-procedure durable PV isolation. However, the optimal RF power and stability criteria is unknown.

OBJECTIVES: With this study, we aim at evaluation the efficacy and the safety of higher power (45 watts) and stricter stability criteria (3 mm for 3 sec) as compared to a standard CLOSE protocol (35 watts with stability of 3 mm for 8 sec) in patients referred for a first ablation for paroxysmal AF.

POPULATION: Eligible patients are patients with paroxysmal AF who are planned for a 'CLOSE'-guided PV isolation for paroxysmal AF. At the time of the procedrual planning, we will ask the patient his/her consent for collectio of data. We aim at including 100 patients.

Study Design

Conditions

Atrial Fibrillation

Intervention

High power CLOSE-guided PVI ablation, Standard CLOSE-guided PVI ablation

Location

Department of Cardiology
Bruges
Belgium
8000

Status

Recruiting

Source

AZ Sint-Jan AV

Results (where available)

View Results

Links

Published on BioPortfolio: 2019-10-16T10:39:24-0400

Clinical Trials [4349 Associated Clinical Trials listed on BioPortfolio]

Registry Evaluating AF Ablation Techniques

The purpose of this observational registry is to prospectively collect procedure efficiency, safety and acute and long term outcome data from catheter ablation procedures as treatment of p...

High Radiofrequency Power for Faster and Safer Pulmonary Veins Ablation Trial (POWER FAST II)

Multicenter 1:1 randomized study. Two atrial fibrillation ablation strategies are compared: 1) conventional ablation using point-by-point radiofrequency applications with power 40 W guided...

CFAEs Guided Ablation Versus PVI in Persistent AF

Objective: The purpose of this study is to compare the efficacy and safety of complex fractionated atrial electrocardiograms (CFAEs) guided ablation to pulmonary vein isolation based ablat...

Pulmonary Vein Isolation With Versus Without Continued Antiarrhythmic Drugs in Persistent Atrial Fibrillation

In the POWDER 1 study, paroxysmal atrial fibrillation (AF) patients undergoing conventional contact force (CF)-guided PVI were investigated. Patients were randomized between continuing pre...

A Trial of High Power-Short Duration Versus Standard Power-Long Duration Radiofrequency Ablation for Treatment of Atrial Fibrillation

This study is a prospective, randomized controlled study to compare overall clinical outcomes between High Power Short Duration (HPSD) and standard radiofrequency (RF) ablation settings fo...

PubMed Articles [22081 Associated PubMed Articles listed on BioPortfolio]

High power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation.

Ablation index (AI) is useful to complete circumferential pulmonary vein isolation (CPVI) for atrial fibrillation (AF), but the role of radiofrequency power in AI-guided CPVI remains to be elucidated.

Pulmonary vein isolation using ablation index vs. CLOSE protocol with a surround flow ablation catheter.

Pulmonary vein isolation (PVI) using ablation index (AI) incorporates stability, contact force (CF), time, and power. The CLOSE protocol combines AI and ≤6 mm interlesion distance. Safety concerns...

Effects of Focal Impulse and Rotor Modulation-Guided Ablation on Atrial Arrhythmia Termination and Inducibility: Impact on Outcomes after Treatment of Persistent Atrial Fibrillation.

The role of focal impulse and rotor modulation (FIRM)-guided ablation for the treatment of atrial fibrillation (AF) remains unclear. Previous studies on the FIRM-guided ablation outcomes have been lim...

PV isolation guided by esophageal visualization with a tailored ablation strategy for the avoidance of esophageal thermal injury: a randomized trial.

Radiofrequency ablation along the posterior wall of the left atrium may lead to atrioesophageal fistula due to esophageal thermal injury. The purpose of our study was to prospectively investigate whet...

Efficacy of the optimal ablation index-targeted strategy for pulmonary vein isolation in patients with atrial fibrillation: the OPTIMUM study results.

The ablation index (AI) is a recently developed marker for ablation lesion quality that incorporates contact force (CF), time, and power in a weighted formula. There is a paucity of information on whe...

Medical and Biotech [MESH] Definitions

A way of providing nursing care that is guided by the integration of the best available scientific knowledge with nursing expertise. This approach requires nurses to critically assess relevant scientific data or research evidence, and to implement high-quality interventions for their nursing practice.

A way of providing health care that is guided by a thoughtful integration of the best available scientific knowledge with clinical expertise. This approach allows the practitioner to critically assess research data, clinical guidelines, and other information resources in order to correctly identify the clinical problem, apply the most high-quality intervention, and re-evaluate the outcome for future improvement.

Conducting a biopsy procedure with the aid of a MEDICAL IMAGING modality.

The collecting of fetal blood samples via ultrasound-guided needle aspiration of the blood in the umbilical vein.

A way of providing emergency medical care that is guided by a thoughtful integration of the best available scientific knowledge with clinical expertise in EMERGENCY MEDICINE. This approach allows the practitioner to critically assess research data, clinical guidelines, and other information resources in order to correctly identify the clinical problem, apply the most high-quality intervention, and re-evaluate the outcome for future improvement.

More From BioPortfolio on "CLOSE-guided Pulmonary Vein Isolation Using High Power and Stable RF Applications"

Quick Search

Relevant Topic

Cardiology
Cardiology is a specialty of internal medicine.  Cardiac electrophysiology : Study of the electrical properties and conduction diseases of the heart. Echocardiography : The use of ultrasound to study the mechanical function/physics of the h...


Searches Linking to this Trial