Accuracy of Non-Invasive Blood Pressure Measurements at the Arm, Calf , and Finger

2020-02-19 18:28:35 | BioPortfolio

Summary

The present study was designed to assess, in a population of patients admitted to the intensive care unit and already carrying an indwelling arterial catheter, the ability of combined continuous (ClearSight™) and intermittent (automatic cuff) non-invasive monitoring to detect low mean BP (<65mmHg). The intra-arterial measurement will be the reference measurement. As secondary objectives, the investigators will assess the ability of combined continuous (ClearSight™) and intermittent (automatic cuff) non-invasive monitoring to detect stage 2 hypertension, and to detect changes in BP during a cardiovascular intervention (as clinically indicated but not imposed by the study protocol). Additionally, the accuracy of both devices against the current international standard (ISO standard) will be assessed.

Description

The measurement of arterial blood pressure (BP) is of paramount importance when caring for critically ill patients, as BP, especially mean BP, is the driving force of blood flow through all the organs. The reference method is the invasive method that measures BP continuously and directly in an artery (most often the radial artery), through an indwelling arterial catheter. A popular, less invasive method, most often used in emergency situations or during the first hours of care in the intensive care unit (ICU), is the non-invasive oscillometric method (NIBP) using an arm cuff (some have shown that the cuff could also be placed around the calf, just above the ankle), that provides only intermittent measurements. In between the above 2 techniques, the place of continuous non-invasive BP monitoring devices using a different technology (plethysmography and volume clamp technique) and a cuff placed around a finger is uncertain. It would be interesting to evaluate whether the 2 non-invasive techniques (using arm or finger cuff) can be advantageously combined either to replace invasive monitoring or to reinforce non-invasive monitoring (in patients in whom an arterial catheter is not envisaged). In the critically ill patient, reliable detection of low BP is often the most important task assigned to BP monitoring devices, at least in the initial phase of management. It is conceivable that if the finger cuff (ClearSight™ device) was not infallible in measuring BP, low BP could still be detected sufficiently reliably by the finger cuff (even with weak accuracy), giving an early warning. The arm measurement could then confirm hypotension in a robust, on-demand manner, since the ability of the arm cuff to detect hypotension has already been demonstrated. The ability to detect hypotension using a combined non-invasive approach (finger and arm cuff) has never been explored with the ClearSight™ device. This combined approach could similarly detect high blood pressure or a rapid change in BP as a result of cardiovascular intervention. In addition, the automatic cuff cannot always be placed around the arm (presence of wounds, burns, fractures or surgery of the upper limb, venous catheter, etc.) for intermittent NIBP measurements, and is then placed around the calf. However, this commonly observed practice exposes the NIBP measurement to less accuracy. The finger cuff could be an alternative to the calf cuff. However, the accuracy of finger measurement has never been compared to the accuracy of oscillometric measurement at the calf.

Study Design

Conditions

Hypotension and Shock

Intervention

Combined non-invasive intermittent (oscillometric arm cuff), non-invasive continuous (finger cuff and ClearSight device), and invasive continuous (intra-arterial catheter) BP measurements

Status

Not yet recruiting

Source

Centre Hospitalier Régional d'Orléans

Results (where available)

View Results

Links

Published on BioPortfolio: 2020-02-19T18:28:35-0500

Clinical Trials [4581 Associated Clinical Trials listed on BioPortfolio]

Detecting Hypotension By Continuous Non-invasive Arterial Pressure Monitoring

The purpose of this study is to determine whether continuous non-invasive arterial pressure (CNAP) monitoring is beneficial to maintain maternal hemodynamic stability and improve the outco...

Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis

There is growing evidence that central blood pressure is a better predictor of hypertensive end-organ damage and cardiovascular outcome than routine brachial readings. We aimed to evaluat...

Non-invasive Versus Invasive Blood Pressure Measurement in the Super Morbidly Obese Parturient With Severe Preeclampsia

The study will compare agreement of invasive blood pressure measurements with non-invasive blood pressure measurements measured with a conical blood pressure and large standard upper arm r...

Accuracy of Non-invasive Non-oscillometric Blood Pressure Wristband

The primary objective of the present investigation is to determine the accuracy of a non-invasive non-oscillometric blood pressure wristband device when compared to invasive intra-arterial...

Non-invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis

There is growing evidence that central blood pressure is a better predictor of hypertensive end-organ damage and cardiovascular outcome than routine brachial readings. The investigators a...

PubMed Articles [7080 Associated PubMed Articles listed on BioPortfolio]

Development of a Cuff-Less Blood Pressure Monitoring System and Its Application.

We present an unobtrusive cuff-less sphygmomanometer based on contact-type and optical pulse sensors for continuous and minimally invasive monitoring of blood pressure (BP). We developed a cuff-less s...

Parametric characterization of the rat Hering-Breuer reflex evoked with implanted and non-invasive vagus nerve stimulation.

Vagus nerve stimulation (VNS) has rapidly gained interest as a treatment for a variety of disorders. A number of methods have been employed to stimulate the vagus nerve, but the most common relies on ...

Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study.

Hypotension during general anesthesia is associated with poor outcome. Continuous monitoring of mean blood pressure (MAP) during anesthesia is useful and needs to be reliable and minimally invasive. C...

Blood pressure measurement by oscillometric and auscultatory methods in normotensive pregnant women.

to compare blood pressure values obtained by auscultatory and oscillometric methods in different gestational periods, considering cuff width.

Non-invasive continuous haemodynamic monitoring and response to intervention in haemodynamically unstable patients during rapid response team review.

During Rapid Response Team (RRT) management of haemodynamic instability (HI), continuous non-invasive haemodynamic monitoring may provide supplemental physiological information.

Medical and Biotech [MESH] Definitions

Lung infections with the invasive forms of ASPERGILLUS, usually after surgery, transplantation, prolonged NEUTROPENIA or treatment with high-doses of CORTICOSTEROIDS. Invasive pulmonary aspergillosis can progress to CHRONIC NECROTIZING PULMONARY ASPERGILLOSIS or hematogenous spread to other organs.

Diagnostic and therapeutic procedures that are invasive or surgical in nature, and require the expertise of a specially trained radiologist. In general, they are more invasive than diagnostic imaging but less invasive than major surgery. They often involve catheterization, fluoroscopy, or computed tomography. Some examples include percutaneous transhepatic cholangiography, percutaneous transthoracic biopsy, balloon angioplasty, and arterial embolization.

Procedures that avoid use of open invasive surgery in favor of closed or local surgery. These generally involve use of laparoscopic devices and remote-control manipulation of instruments with indirect observation of the surgical field through an endoscope or similar device. With the reduced trauma associated with minimally invasive surgery, long hospital stays may be reduced with increased rates of short stay or day surgery.

Procedures that avoid use of open, invasive surgery in favor of closed or local surgery. These generally involve use of laparoscopic devices and remote-controlled manipulation of instruments with indirect observation of the surgical field through an endoscope or similar device.

A uterine tumor derived from persistent gestational TROPHOBLASTS, most likely after a molar pregnancy (HYDATIDIFORM MOLE). Invasive hyadatiform mole develops in about 15% of patients after evacuation of a complete mole and less frequently after other types of gestation. It may perforate the MYOMETRIUM and erode uterine vessels causing hemorrhage.

More From BioPortfolio on "Accuracy of Non-Invasive Blood Pressure Measurements at the Arm, Calf , and Finger"

Quick Search

Searches Linking to this Trial