Advertisement

Topics

Continuous Glucose Monitoring to Measure Effect of Glycemic Index

2014-08-27 03:12:50 | BioPortfolio

Summary

Background: Post-prandial hyperglycemia is common in people with type 1 diabetes.

Objective: The aim was to determine the impact of low vs high glycemic index (GI) on post-prandial glycemia for breakfast vs lunch and to quantify these effects with continuous glucose monitoring.

Design: Seven adult subjects with type 1 diabetes participated in two experiments, each consisting of two meals each. In one experiment, both meals had a low GI; in the other, high GI. Meals were given 195 minutes apart and were matched for carbohydrate, protein, and fat content. Each subject received his usual pre-prandial insulin dosage, followed by a continuous subcutaneous basal insulin infusion for the remainder of the experiment. Arterialized venous glucose was analyzed every 15 minutes and sensor glucose was recorded every 5 minutes.

Description

A total of 14 diet studies (each with two meals) were completed in three men and four women. All subjects completed two diet studies in which two meals were served 195 minutes apart. On one study day, two high GI (> 75) meals were given, and on the other study day, two low GI (< 30) meals were given. The low GI and high GI meals were matched for amount of carbohydrates, protein, and fat based on a weight-maintaining diet for each subject. The order of the study treatment (high or low GI) was randomized. Subjects were not informed as the GI of any meal.

Study Design

Allocation: Randomized, Intervention Model: Crossover Assignment, Masking: Single Blind (Subject), Primary Purpose: Supportive Care

Conditions

Type 1 Diabetes Mellitus

Intervention

Dexcom Seven® Plus Continuous Glucose Monitoring sensor

Location

Legacy Health System--Holladay Park Campus
Portland
Oregon
United States
97232

Status

Completed

Source

Legacy Health System

Results (where available)

View Results

Links

Published on BioPortfolio: 2014-08-27T03:12:50-0400

Clinical Trials [2955 Associated Clinical Trials listed on BioPortfolio]

Standardized Evaluation of Subcutaneous Glucose Monitoring Systems Under Routine Environmental Conditions

The purpose of this study is to assess accuracy and reliability of the SPIDIMAN CGM sensor system with regard to values as measured by Super GL and compare these results with similar evalu...

Effectiveness and Safety Study of the Next-Generation DexCom™ SEVEN® Continuous Glucose Monitoring System

The purpose of this study is to evaluate the safety and effectiveness of the next-generation DexCom SEVEN Continuous Glucose Monitoring System (SEVEN.2 System) when worn for up to 7-days b...

An Evaluation of a Novel Glucose Sensing Technology in Type 2 Diabetes

To evaluate the impact of the Abbott Sensor Based Glucose Monitoring System on glycaemic control (HbA1c) compared to Self Monitoring Blood Glucose (SMBG) testing using a randomised control...

Metronom Continuous Glucose Monitoring System

The aim of the present study is to investigate the clinical performance of the Metronom CGM system in patients with type 1 diabetes over a period of 14 days. In this study, the CGM sensor ...

A French Study to Evaluate the Usefulness of Implantable Continuous Glucose Monitoring (CGM) Sensor to Improve Glycemic Control in Participants With Diabetes Mellitus.

This study will evaluate the usefulness of using a long term subcutaneously inserted continuous glucose monitoring (CGM) sensor in patients with insulin treated Type 1 or Type 2 Diabetes M...

PubMed Articles [15617 Associated PubMed Articles listed on BioPortfolio]

Continuous Glucose Monitoring Use and Glucose Variability in Pre-school Children with Type 1 Diabetes.

The objective of this nationwide population-based cohort study was to evaluate the correlation between continuous glucose monitoring (CGM) use and glucose variability in pre-schoolers with type 1 diab...

Effect of sensor location on continuous intraperitoneal glucose sensing in an animal model.

In diabetes research, the development of the artificial pancreas has been a major topic since continuous glucose monitoring became available in the early 2000's. A prerequisite for an artificial pancr...

Development of a third-generation glucose sensor based on the open circuit potential for continuous glucose monitoring.

Continuous glucose monitoring (CGM) systems are most important in the current Type I diabetes care and as component for the development of artificial pancreas systems because the amount of insulin bei...

A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.

To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control.

Are glucose profiles well-controlled within the targets recommended by the International Diabetes Federation in type 2 diabetes? A meta-analysis of results from continuous glucose monitoring based studies.

To assess continuous glucose monitoring (CGM) derived intra-day glucose profiles using global guideline for type 2 diabetes recommended by the International Diabetes Federation (IDF).

Medical and Biotech [MESH] Definitions

A glucose transport facilitator that is expressed primarily in PANCREATIC BETA CELLS; LIVER; and KIDNEYS. It may function as a GLUCOSE sensor to regulate INSULIN release and glucose HOMEOSTASIS.

A glucoside-derived SODIUM-GLUCOSE TRANSPORTER 2 inhibitor that stimulates urinary excretion of glucose by suppressing renal glucose reabsorption. It is used to manage BLOOD GLUCOSE levels in patients with TYPE 2 DIABETES.

The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine.

Self evaluation of whole blood glucose levels outside the clinical laboratory. A digital or battery-operated reflectance meter may be used. It has wide application in controlling unstable insulin-dependent diabetes.

Simultaneous and continuous monitoring of several parameters during sleep to study normal and abnormal sleep. The study includes monitoring of brain waves, to assess sleep stages, and other physiological variables such as breathing, eye movements, and blood oxygen levels which exhibit a disrupted pattern with sleep disturbances.

More From BioPortfolio on "Continuous Glucose Monitoring to Measure Effect of Glycemic Index"

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topic

Nephrology - kidney function
Nephrology is a specialty of medicine and pediatrics that concerns itself with the study of normal kidney function, kidney problems, the treatment of kidney problems and renal replacement therapy (dialysis and kidney transplantation). Systemic conditions...


Searches Linking to this Trial