Advertisement

Topics

Clinical Study to Evaluate the Catheter Robotics Amigo for Performing Right-Sided Electrophysiology Mapping Studies

2014-08-27 03:13:03 | BioPortfolio

Summary

The purpose of this clinical study is to collect safety and performance data to support a demonstration of substantial equivalence of the Catheter Robotics Remote Catheter System to predicate devices when used to perform EP mapping of the right heart (atrium and ventricle).

Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic

Conditions

Atrial Flutter

Intervention

Amigo catheter robot

Status

Not yet recruiting

Source

Catheter Robotics, Inc.

Results (where available)

View Results

Links

Published on BioPortfolio: 2014-08-27T03:13:03-0400

Clinical Trials [827 Associated Clinical Trials listed on BioPortfolio]

Thermocool SF Catheter Versus Thermocool Catheter in Isthmus-dependent Atrial Flutter Ablation

Porous tip catheter use reduces procedure time and RF time in atrial flutter ablation with the same safety.

Catheter Evaluation for Endocardial Ablation in Patients With Typical Atrial Flutter

The primary objective is to provide additional corroborative safety and efficacy data for the Navistar Thermocool catheter for the treatment of subjects with typical atrial flutter (AFL).

Catheter Ablation as the First Line Therapy for Typical Atrial Flutter

Catheter ablation of typical atrial flutter is a well established technique with a high acute success rate and very low complication and recurrence rates. It has also been shown that ablat...

Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter II

The purpose of this clinical study is to evaluate the and performance of the Imricor Medical Systems, Inc. (Imricor) MR Ablation Catheter when used with related accessories for the treatme...

Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter

The purpose of this clinical study is to evaluate the and performance of the Imricor Medical Systems, Inc. (Imricor) MR Ablation Catheter when used with related accessories for the treatme...

PubMed Articles [1587 Associated PubMed Articles listed on BioPortfolio]

Randomized controlled trial of Amigo® robotically controlled versus manually controlled ablation of the cavo-tricuspid isthmus using a contact force ablation catheter.

Radiofrequency catheter ablation (RFCA) of the cavo-tricuspid isthmus (CTI) is a common treatment for atrial flutter (AFL). However, achieving bi-directional CTI conduction block may be difficult, par...

Digoxin for atrial fibrillation and atrial flutter: A systematic review with meta-analysis and trial sequential analysis of randomised clinical trials.

During recent years, systematic reviews of observational studies have compared digoxin to no digoxin in patients with atrial fibrillation or atrial flutter, and the results of these reviews suggested ...

CHA₂DS₂-VASc Score in the Prediction of Ischemic Stroke in Patients after Radiofrequency Catheter Ablation of Typical Atrial Flutter.

Despite undergoing successful catheter ablation of typical atrial flutter (AFL), patients remain at increased risk for ischemic stroke. However, data on risk prediction tools for the development of st...

Left atrial thrombus and dense spontaneous echocardiographic contrast in patients on continuous direct oral anticoagulant therapy undergoing catheter ablation of atrial fibrillation: Comparison of dabigatran, rivaroxaban, and apixaban.

Left atrial thrombus (LAT) and dense spontaneous echocardiographic contrast (SEC) detected by transesophageal echocardiography (TEE) in patients on continuous direct oral anticoagulants (DOAC) therapy...

Comparative Risks of Ischemic Stroke in Atrial Flutter versus Atrial Fibrillation.

The aim of this study was to compare the risk of ischemic stroke in patients who have atrial fibrillation and patients who have atrial flutter.

Medical and Biotech [MESH] Definitions

Rapid, irregular atrial contractions caused by a block of electrical impulse conduction in the right atrium and a reentrant wave front traveling up the inter-atrial septum and down the right atrial free wall or vice versa. Unlike ATRIAL FIBRILLATION which is caused by abnormal impulse generation, typical atrial flutter is caused by abnormal impulse conduction. As in atrial fibrillation, patients with atrial flutter cannot effectively pump blood into the lower chambers of the heart (HEART VENTRICLES).

The pressure within the CARDIAC ATRIUM. It can be measured directly by using a pressure catheter (see HEART CATHETERIZATION). It can be also estimated using various imaging techniques or other pressure readings such as PULMONARY CAPILLARY WEDGE PRESSURE (an estimate of left atrial pressure) and CENTRAL VENOUS PRESSURE (an estimate of right atrial pressure).

Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery.

A potentially lethal cardiac arrhythmia characterized by an extremely rapid, hemodynamically unstable ventricular tachycardia (150-300 beats/min) with a large oscillating sine-wave appearance. If untreated, ventricular flutter typically progresses to VENTRICULAR FIBRILLATION.

Long-term changes in the electrophysiological parameters and/or anatomical structures of the HEART ATRIA that result from prolonged changes in atrial rate, often associated with ATRIAL FIBRILLATION or long periods of intense EXERCISE.

More From BioPortfolio on "Clinical Study to Evaluate the Catheter Robotics Amigo for Performing Right-Sided Electrophysiology Mapping Studies"

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topic

Cardiovascular disease (CVD)
Acute Coronary Syndromes (ACS) Blood Cardiovascular Dialysis Hypertension Stent Stroke Vascular Cardiovascular disease (CVD) includes all the diseases of the heart and circulation including coronary heart disease (angina...


Searches Linking to this Trial