Patient Comfort With Vascular Closure

2014-08-27 03:18:34 | BioPortfolio

Summary

The purpose of this research study is to collect information on the amount of discomfort patients experience with one of two different vascular blood vessel closure devices, the MynxM5 Vascular Closure Device and the Angio-Seal Evolution Vascular Closure Device.

Description

The traditional, standard technique of achieving femoral artery hemostasis following diagnostic and interventional catheterization procedures requires compression methods such as manual pressure or clamps held at the puncture site for 10 to 30 minutes, or even longer depending on sheath size and anticoagulation status. This traditional method can be associated with patient discomfort as well as prolonged bed rest, ambulation and hospital discharge.

Over the past decade, Vascular Closure Devices (VCDs), which include collagen hemostasis devices, percutaneous suture-mediated closure devices and metallic clips, have emerged as a novel means for reducing time to hemostasis and ambulation following catheterization procedures performed utilizing femoral arterial access. Previous studies with commercially available VCDs have shown that the reduction in time to hemostasis and time to ambulation and discharge have also led to increased patient satisfaction over manual compression.

The MynxM5 Vascular Closure Device received FDA approval on April 8, 2009. Like the Mynx 6/7F Vascular Closure Device, which received FDA approval on May 16, 2007, both are designed to achieve femoral artery hemostasis via delivery of an extravascular, water-soluble synthetic sealant which expands upon contact with subcutaneous fluids to seal the arteriotomy. In theory, the lack of pressure needed to clamp, suture, clip or cinch, which is required with intravascular closure devices, may provide an advantage in regards to increased patient comfort during closure device deployment when using the Mynx.

Although VCDs have demonstrated an increase in patient comfort and satisfaction over manual compression, little data exists regarding patient comfort when comparing different closure devices. This study is designed to evaluate patient comfort between the MynxM5 and Angio-Seal Evolution Vascular Closure Devices.

Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment

Conditions

Vascular Closure

Intervention

Mynx Vascular Closure Device, AngioSeal Vascular Closure Device

Location

University of Florida
Gainesville
Florida
United States
32610

Status

Recruiting

Source

University of Florida

Results (where available)

View Results

Links

Published on BioPortfolio: 2014-08-27T03:18:34-0400

Clinical Trials [5333 Associated Clinical Trials listed on BioPortfolio]

Accelerated Ambulation After Vascular Access Closure Device

The researchers are seeking to study whether or not there is benefit in keeping patients flat after Angioseal for extended periods of time after diagnostic heart catheterization or if a mo...

MANTA Vascular Closure Device - EU Registry

The aim of this observational post market study is to compile real world outcome data on the use of the Conformité Européenne (CE) marked MANTA Vascular Closure Device following percutan...

Clinical Study to Evaluate the Safety and Performance of MANTA Vascular Closure Device

The purpose of this study is to evaluate the safety and performance of the MANTA Vascular Closure Device (VCD) to close the arteriotomy following percutaneous cardiovascular procedures uti...

InSeal VCD Large Bore Vascular Closure Device Safety and Effectiveness Clinical Study

The InSeal vascular closure device (VCD) is assessed as percutaneous closure of artery access sites for quick hemostasis and ambulation in patients who have undergone large bore endovascul...

Safety and Performance Study of Large Hole Vascular Closure Device

The purpose of this Clinical Investigation is to validate that the clinical use of the VIVASURE CLOSURE DEVICE™ is safe for the operator, patient and third parties, and to confirm its pe...

PubMed Articles [6096 Associated PubMed Articles listed on BioPortfolio]

AbsorbaSeal™ Vascular Closure Device: A Novel Device for Hemostasis Following Interventional Peripheral Vascular Procedures.

Vascular closure devices (VCDs) are designed to achieve rapid hemostasis during percutaneous coronary and peripheral vascular procedures. Studies demonstrate that VCDs improve time to hemostasis (TTH)...

A New Device for Securing Sternal Wires After Median Sternotomy: Biomechanical Study and Retrospective Clinical Assessment.

Morbidity due to sternotomy continues to be a significant clinical problem. Poor approximation of the sternum may lead to complications such as sternal dehiscence, infection, and pain. A device to ass...

Use of vascular closure devices for endovascular interventions requiring a direct puncture of PETE grafts.

Effectiveness of vascular closure devices during endovascular procedures requiring a direct puncture of a vascular prosthesis placed in the inguinal region is unknown.

Peratrial Device Closure of Different Locations of Mitral Paravalvular Leaks.

The current approaches of transcatheter closure of mitral paravalvular leak (MPVL) have different drawbacks. The challenges come from transseptal puncture, accessing the MPVL site, and the absence of ...

MynxGrip vascular closure device use in pediatric neurointerventional procedures.

OBJECTIVE The aim of this paper was assess the efficacy and safety of using the MynxGrip arterial closure device in pediatric neuroendovascular procedures where the use of closure devices remains off-...

Medical and Biotech [MESH] Definitions

Products used to seal the openings in BLOOD VESSELS from incisions or punctures made during ENDOVASCULAR PROCEDURES.

Removal of a MEDICAL DEVICE from the market due to the identification of an intrinsic property of the device that results in a serious risk to public health.

The tendency to perceive an incomplete pattern or object as complete or whole. This includes the Gestalt Law of Closure.

Therapeutic closure of spaces caused by the extraction of teeth, the congenital absence of teeth, or the excessive space between teeth.

Device designed to wear externally to support muscular skeletal system in various movements such as RANGE OF MOTIONS; WEIGHT-BEARING; GAIT; and LOCOMOTION.

More From BioPortfolio on "Patient Comfort With Vascular Closure"

Advertisement
Quick Search
Advertisement
Advertisement

 

Relevant Topic

Blood
Blood is a specialized bodily fluid that delivers necessary substances to the body's cells (in animals) – such as nutrients and oxygen – and transports waste products away from those same cells.  In vertebrates, it is composed of blo...


Searches Linking to this Trial