We list hundreds of Clinical Trials about "GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular" on BioPortfolio. We draw our references from global clinical trials data listed on ClinicalTrials.gov and refresh our database daily.

More Information about "GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular" on BioPortfolio

We have published hundreds of GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular news stories on BioPortfolio along with dozens of GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular Clinical Trials and PubMed Articles about GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular for you to read. In addition to the medical data, news and clinical trials, BioPortfolio also has a large collection of GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular Companies in our database. You can also find out about relevant GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular Drugs and Medications on this site too.

Showing "GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular" Clinical Trials 1–25 of 6,800+

Extremely Relevant

GORE VIABAHN® Versus Plain Old Balloon Angioplasty (POBA) for Superficial Femoral Artery (SFA) In-Stent Restenosis

This is a prospective, randomized, multi-center study recruiting patients with an in-stent restenosis in the superficial femoral artery. The safety and efficacity of the Viabahn endoprosthesis (W.L. Gore & Associates), a heparin-bonded endoprosthesis, is compared with plain old balloon angioplasty (POBA). In 4 Belgian and 2 German centers a total of 80 Patients will be recruited. Primary endpoint is primary patency at 12 months, defined as no evidence of restenosis or occlusion...


Post-Market Registry of the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis Implanted in Peripheral Vessels

The primary objective of the VBX 17-04 registry is to collect post-market safety and performance data of the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis (VBX Stent Graft) in peripheral vessels in patients who require interventional treatment

GORE VIABAHN Endoprosthesis With Heparin Bioactive Surface in the Treatment of SFA Obstructive Disease (VIPER)

The objective of the study is collect data on the GORE VIABAHN Endoprosthesis with Heparin Bioactive Surface in the treatment of chronic Superficial Femoral Artery disease. Device patency at 12 months is the primary endpoint.


In-Stent Restenosis Post-Approval Study

The objective of the ISR 14-04 study is to evaluate post-market safety and effectiveness of GORE® VIABAHN® Endoprosthesis for treatment of In-Stent Restenosis of the Superficial Femoral Artery.

Prime Time for Superficial Femoral Artery (SFA) - The SFA Study

The purpose of this study is to compare the different endovascular treatment modalities for the femoropopliteal segment, and to determine technical success, efficacy and patency at mid-term follow-up. Modalities include; Angioplasty/stent (Control group, Guidant), Cryoplasty/stent (Boston Scientific), Laser Angioplasty/stent (Spectranetics), SilverHawk Atherectomy/stent (Fox Hollow), and Viabahn Endograft (WL Gore).

Study to Evaluate the Safety and Performance of Spectranetics Laser w/Adjunct PTA and Gore Viabahn Endoprosthesis for Treatment of SFA Instent Restenosis

A Multicenter study to evaluation the safety and performance of Spectranetics Laser with Adjunct PTA and Gore Viabahn Endoprosthesis for the Treatment of SFA Instent Restenosis

Balloon Angioplasty vs. Cutting Balloon Angioplasty of Femoropopliteal Arteries- a Randomized Controlled Trial

The purpose of this study to compare balloon angioplasty (PTA) vs. cutting balloon angioplasty (CB-PTA) in terms of patency and postintervention inflammation in peripheral artery disease.

JET-PCB Trial - JETStream Atherectomy With Adjunctive Paclitaxel-Coated Balloon Angioplasty vs Plain Old Balloon Angioplasty Followed by Paclitaxel-Coated Balloon

A prospective, multicenter, randomized study evaluating the use of Jetstream Atherectomy (JS) followed by DCB in comparison to the use of plain old balloon angioplasty (POBA) followed by DCB alone in the treatment of complex lesions in femoropopliteal arteries in subjects with claudication (Rutherford Clinical Category (RCC) of 2-4) (complex lesions are defined as long (≥ 10 cm) lesions, or moderately or highly calcified lesions, or chronic total occlusions irrespective of le...

Assessment of the GORE® EXCLUDER® Conformable AAA Endoprosthesis in the Treatment of Abdominal Aortic Aneurysms- High Neck Angulation Substudy

The purpose of the study is to assess the safety and effectiveness of the GORE® EXCLUDER® Conformable AAA Endoprosthesis to treat an infrarenal aneurysm located in the abdominal aorta. Performance of the GORE® EXCLUDER® Conformable AAA Endoprosthesis will be judged by separate performance goals.

Assessment of the GORE® EXCLUDER® Conformable AAA Endoprosthesis in the Treatment of Abdominal Aortic Aneurysms- Short Neck Substudy

The purpose of the study is to assess the safety and effectiveness of the GORE® EXCLUDER® Conformable AAA Endoprosthesis to treat an infrarenal aneurysm located in the abdominal aorta. Performance of the GORE® EXCLUDER® Conformable AAA Endoprosthesis will be judged by separate performance goals.

Evaluation of the GORE TAG Thoracic Endoprosthesis in the Treatment of Aneurysms

The purpose of this post-approval study is to evaluate the long-term performance of the GORE TAG® Thoracic Endoprosthesis (TAG device) in the primary treatment of descending thoracic aortic (DTA) aneurysms

Drug Coated Balloons vs Plain Balloons for the Management of Dysfunctional Dialysis Fistula

Compare the effectiveness of drug-coated balloons to plain balloon angioplasty in reducing stenosis rates in dialysis arteriovenous fistulas (AVFs).

Study to Evaluate the Lower Extremity Intervention With Integrated Embolic Protection Using the Vanguard IEP System

The ENTRAP Study is a prospective, multi-center, non-randomized, single-arm, study with follow-up to 30 days to determine the acute safety, acute device performance and clinical performance of the Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection. The Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection is indicated for peripheral vascular percutaneous transluminal angioplasty (PTA) and capture and removal of ...

Effectiveness of Paclitaxel-coated Luminor® Balloon Catheter Versus Uncoated Balloon Catheter in the Arteria Femoralis Superficialis

The aim of this clinical trial is to evaluate the safety and efficacy of the novel Luminor® paclitaxel drug‐eluting balloon (iVascular, S.L.U., Barcelona, Spain) in inhibiting restenosis and in ensuring long‐term patency.

GORE EXCLUDER® Endoprosthesis - Low Permeability in Treatment of AAA

The purpose of this study is to evaluate the performance of the GORE EXCLUDER® Bifurcated Endoprosthesis-Low Permeability in the primary treatment of infrarenal abdominal aortic aneurysms.

Evaluation of Peri-surgical Results at Short and Mean Terms of the GORE ® Excluder Iliac Branch Endoprosthesis

The aim of this project is to demonstrate the benefit of the use of aortic iliac branch endoprosthesis in the iliac aneurysms and to avoid the classic complications.

Efficacy Study of Paclitaxel-eluting Balloon, -Stent vs. Plain Angioplasty for Drug-eluting Stent Restenosis

The purpose of this randomized study is to determine which treatment option, either paclitaxel-eluting balloon, paclitaxel-eluting stent or plain balloon angioplasty is the most effective in the treatment of restenosis after implantation of "Limus"-eluting stents, (LES).

Comparison of Prosthetic Femoropopliteal Bypass Versus Viabahn Endoprosthesis for Treatment of Symptomatic Femoral Artery Occlusive Disease

This study is a comparison of two different ways to treat blockage in the artery of the thigh. The first is an older way with incisions in the groin and just above the knee. A plastic tube is then inserted to make a bypass from the groin to the knee. The second treatment offered is through a needle hole in the groin. A thin plastic tube covering a metal stent is inserted into the artery and released to bypass the blockage from inside the artery. No incisions are needed. P...

Evaluation of the GORE® TAG® Thoracic Branch Endoprosthesis (TBE Device) in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta (Zone 0/1)

The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta.

Vienna Absolute Trial: Balloon Angioplasty Versus Stenting in the Superficial Femoral Artery

Minimal invasive treatment (called "endovascular") of the arteries of the lower limb remains problematic, because recurrent disease ("restenosis") frequently leads to recurrent symptoms. As yet, balloon angioplasty remains the recommended strategy to revascularize the superficial femoral artery (artery of the thigh). We investigated whether the use of a vascular endoprosthesis ("stent") improves patients´ outcome. Study hypothesis: Primary stenting with self expanding nitinol...

Evaluation of the GORE® TAG® Thoracic Branch Endoprosthesis (TBE Device) in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta (Zone 2)

The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta.

The Paclitaxel-Eluting Percutaneous Coronary Angioplasty (PTCA)-Balloon Catheter for the Treatment of Coronary Bifurcations

The intention of this trial is to assess the safety and efficacy of Drug Eluting Balloon (DEB) application (SeQuent Please) to the side branch in percutaneous coronary intervention (PCI) of Medina 0,0,1 coronary bifurcation lesions. Patients will be randomized to treatment with Plain Old Balloon Angioplasty (POBA)or treatment with DEB.

Systematic Review and Meta-Analysis on DCB vs. POBA in De-novo Femoropopliteal Disease

Restenosis is still an issue after endovascular revascularization for femoropopliteal occlusive disease. One approach to reduce the rates of restenosis and reintervention is local application of Paclitaxel with drug-coated balloon angioplasty. The purpose is to conduct a systematic review and meta-analysis of randomized-controlled trials comparing on Drug-Coated Balloon angioplasty (DCB) vs. Plain Old Balloon Angioplasty (POBA) in de-novo femoropopliteal disease.

Drug-coated Balloon Versus Conventional Balloon Angioplasty in Hemodialysis Graft

To evaluate the role of DCB angioplasty for venous anastomotic stenosis of hemodialysis graft, investigators would like to perform randomized study comparing the results of drug- coated balloon angioplasty with conventional balloon angioplasty in the treatment in venous anastomotic stenosis of AVG in terms of patency.

Athrectomy and Drug Eluting Balloon Therapy (ADEBT) on the Femoral Popliteal Arteries

The aim of this study is to study the effects of athrectomy followed by percutaneous transluminal angioplasty using Paclitaxel coated Drug Eluting Balloon (DEB) in treating de novo or re-stenotic lesions in the femoral-popliteal artery in patients with symptomatic peripheral vascular disease in an Asian population. We intend to study the effects of debulking athrectomy followed by application of DEBs to prevent restenosis, resulting in improved patency rates The study will pros...


More From BioPortfolio on "GORE VIABAHN Endoprosthesis Plain balloon angioplasty Peripheral Vascular"