Test-retest variability in structural parameters measured with glaucoma imaging devices.

16:39 EDT 22nd May 2015 | BioPortfolio

Summary of "Test-retest variability in structural parameters measured with glaucoma imaging devices."

In addition to classical stereo-disc photography, various glaucoma imaging devices were developed in the last two decades to quantitatively measure and record glaucoma-related structural parameters of the eye. In determining whether or not the glaucomatous damage progressed from baseline and in estimating the number of test results' optimal frequency needed to confirm disease progression, information relating to the test-retest variability of measurement results provided by each imaging device is indispensable. Such information enables the clinician to apply these devices in practice. The test-retest variability of a system is usually estimated using the Bland-Altman analysis and by calculating the coefficient of variation (CV), intraclass correlation coefficient (ICC), and minimum detectable changes (MDC). The reported CV, ICC, and MDC values for glaucoma-related structural parameter measurement results of stereo-disc photographs, confocal scanning laser ophthalmoscopes, scanning laser polarimeters, time-domain optical coherence tomography (OCT), spectral-domain OCT (SD-OCT), anterior-segment OCT, and ultrasound biomicroscope are systematically reviewed in this manuscript, which will enable the clinician to interpret measurement results provided by each glaucoma imaging devices and thus be useful in practice. Although SD-OCT systems may be currently prevailing because of the volume of information provided and the relatively better test-retest variability, these systems need improvement in their test-retest variability measurement capabilities.

Affiliation

Kanto Central Hospital of The Mutual Aid Association of Public School Teachers, 6-25-1 Kamiyoga, Setagaya-ku, Tokyo, 158-8531, Japan, araie-tky@umin.net.

Journal Details

This article was published in the following journal.

Name: Japanese journal of ophthalmology
ISSN: 1613-2246
Pages:

Links

PubMed Articles [22462 Associated PubMed Articles listed on BioPortfolio]

Long-term test-retest reliability of striatal and extrastriatal dopamine D2/3 receptor binding: study with (11)Craclopride and high-resolution PET.

We measured the long-term test-retest reliability of [(11)C]raclopride binding in striatal subregions, the thalamus and the cortex using the bolus-plus-infusion method and a high-resolution positron e...

DEVELOPMENT OF AUTOMATED GAIT ASSESSMENT ALGORITHM USING THREE INERTIAL SENSORS AND ITS RELIABILITY.

The aim of this study was to develop a sensor based gait assessment algorithm and investigate the concurrent test-retest (split-half) reliability and inter-instrument reliability of inertial measureme...

WIDE RANGE ACHIEVEMENT TEST IN AUTISM SPECTRUM DISORDER: TEST-RETEST STABILITY.

-The principal goal of this descriptive study was to establish the test-retest stability of the Reading, Spelling, and Arithmetic subtest scores of the Wide Range Achievement Test (WRAT-3) across two ...

Test-Retest Variability of Retinal Nerve Fiber Layer Thickness and Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Using Spectral-Domain Optical Coherence Tomography.

To evaluate the test-retest variability of spectral-domain optical coherence tomography (OCT) in measurement of retinal nerve fiber layer (RNFL) thickness and macular ganglion cell-inner plexiform lay...

Test-retest cross-reliability of tests to assess neuromuscular function as a multidimensional concept.

The purpose of this investigation was to estimate the test-retest cross-reliability of peripheral and central changes with respect to nonlinear and linear measures of a surface electromyography (EMG) ...

Clinical Trials [3371 Associated Clinical Trials listed on BioPortfolio]

Effects of Duloxetine vs. Escitalopram on Heart Rate Variability in Depression

Low heart rate variability is a marker of increased risk of cardiac mortality, and is observed in depressed coronary artery disease patients. Some antidepressants may themselves, however,...

Determination of Labor Progression Patterns Using Non-invasive, Ultrasound Based, Multiple Parameters

The purpose of this study is to establish normograms of parameters measured by the LaborPro system. To test the prediction of these parameters on labor progress and mode of delivery.

Omega-3 Fatty Acids in Bipolar Patients With a Low Omega-3 Index and Reduced Heart Rate Variability

This study sets out to test the hypothesis that parameters of heart rate variability, as a non-invasive measure of cardiovascular risk, can be improved by the addition of omega-3 fatty aci...

Heart Rate Variability for Prediction of Perioperative Events

Patients with underlying cardiovascular disease are at high risk of perioperative cardiovascular events and death. Hemodynamic variables are controlled by the autonomic nervous system refl...

Functional and Structural Imaging for Glaucoma

The specific aims of the clinical studies are to: - Improve Doppler OCT measurement of retinal blood flow. - Develop quantitative OCT angiography of the ONH - Measure ner...

Medical and Biotech [MESH] Definitions

A performance test based on forced MOTOR ACTIVITY on a rotating rod, usually by a rodent. Parameters include the riding time (seconds) or endurance. Test is used to evaluate balance and coordination of the subjects, particular in experimental animal models for neurological disorders and drug effects.

An in vitro test used in the diagnosis of allergies including drug hypersensitivity. The allergen is added to the patient's white blood cells and the subsequent histamine release is measured.

The identification of selected parameters in newborn infants by various tests, examinations, or other procedures. Screening may be performed by clinical or laboratory measures. A screening test is designed to sort out healthy neonates (INFANT, NEWBORN) from those not well, but the screening test is not intended as a diagnostic device, rather instead as epidemiologic.

Form of radioimmunoassay in which excess specific labeled antibody is added directly to the test antigen being measured.

Measure of histocompatibility at the HL-A locus. Peripheral blood lymphocytes from two individuals are mixed together in tissue culture for several days. Lymphocytes from incompatible individuals will stimulate each other to proliferate significantly (measured by tritiated thymidine uptake) whereas those from compatible individuals will not. In the one-way MLC test, the lymphocytes from one of the individuals are inactivated (usually by treatment with MITOMYCIN or radiation) thereby allowing only the untreated remaining population of cells to proliferate in response to foreign histocompatibility antigens.

Search BioPortfolio:
Loading
Advertisement

Relevant Topic

Ophthalmology
Latest News Clinical Trials Research Drugs Reports Corporate
Ophthalmology is the branch of medicine that is devoted to the study and treatment of eye diseases. As well as mild visual defects correctable by lenses, ophthalmology is concerned with glaucoma, uveitis and other serious conditions affecting the eye, ...

Advertisement

Searches Linking to this Article